Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Retrospective Analysis of Performance and Safety of MED-EL Cochlear Implants. (BELPS)

7 de setembro de 2026 atualizado por: MED-EL Elektromedizinische Geräte GesmbH

Bern Long-term Performance and Safety of MED-EL Cochlear Implants: a Retrospective Anonymized Analysis of Existing Data From the Local Clinical Database

This study is a single center, non-interventional, retrospective, post-market observational study. Data will be extracted retrospectively from the local clinical database of the site and will be fully anonymized. The data extraction is performed as a one-time process. Following the analysis of the extracted dataset, the study is considered complete.

The study does not foresee any active participation of patients or seeking for consent.

This retrospective anonymized database analysis is performed on all MED-EL cochlear implants registered in the local database of the Department of Otolaryngology, Head and Neck Surgery, Audiology, Inselspital, University of Bern.

The aim of this project is to generate evidence on the clinical effectiveness of cochlear implants based on long term real-world data gathered from clinical routine across a large and diverse population.

Assessed performance outcome measures include word test in quiet results, speech perception in noise results, and patient related outcome measures/questionnaires, as available. Safety assessment is based on data related to revision surgeries, explantations, reimplantations, and any other recorded device related complications. Imaging data (X-ray, CT, MRI) are not used in this study.

Visão geral do estudo

Status

Ainda não está recrutando

Intervenção / Tratamento

Descrição detalhada

This study is a single center, non-interventional, retrospective, post-market observational study. Data will be extracted retrospectively from the local clinical database of the site and will be fully anonymized. The data extraction is performed as a one-time process. Following the analysis of the extracted dataset, the study is considered complete.

The study does not foresee any active participation of patients or seeking for consent.

This retrospective anonymized database analysis is performed on all MED-EL cochlear implants registered in the local database of the Department of Otolaryngology, Head and Neck Surgery, Audiology, Inselspital, University of Bern.

The aim of this project is to generate evidence on the clinical effectiveness of cochlear implants based on long term real-world data gathered from clinical routine across a large and diverse population.

Assessed performance outcome measures include word test in quiet results, speech perception in noise results, and patient related outcome measures/questionnaires, as available. Safety assessment is based on data related to revision surgeries, explantations, reimplantations, and any other recorded device related complications. Imaging data (X-ray, CT, MRI) are not used in this study.

Tipo de estudo

Observacional

Inscrição (Estimado)

700

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Estude backup de contato

Locais de estudo

      • Bern, Suíça, 3010
        • Inselspital, Universitätsspital Bern, Department of Otolaryngology, Head and Neck Surgery, Audiology
        • Contato:
          • Martin Kompis, Prof. Dr. med. Dr. sc. techn.
          • Número de telefone: +41316323300
          • E-mail: martin.kompis@insel.ch
        • Contato:
        • Investigador principal:
          • Martin Kompis, Prof. Dr. med. Dr. sc. techn.
        • Subinvestigador:
          • Christoph Schmid

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho
  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Método de amostragem

Amostra Não Probabilística

População do estudo

The study population includes all patients registered in the sites local database who were implanted with an approved MED-EL cochlear implant at the investigational site since 01st January 1996. To be included for analysis data from the pre-operative assessment and from at least one post-operative assessment must be available.

Descrição

Inclusion Criteria:

  • Implanted with a MED-EL cochlear implant
  • First implantation at Inselspital Bern
  • Implanted later than 31st December 1995

Exclusion Criteria:

  • Lack of compliance with any inclusion criteria
  • Patients implanted with either a custom-made device or with a study device prior CE-marking

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
MED-EL cochlear implant recipients
The cohort includes all patients registered in the sites local database who were implanted with an approved MED-EL cochlear implant at the investigational site since 01st January 1996. To be included for analysis data from the pre-operative assessment and from at least one post-operative assessment must be available.
The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has been made since then. Today, cochlear implantation is the recommended treatment for subjects presenting with a permanent sensorineural hearing loss. Modern, multichannel implant systems feature complex speech processing strategies, high stimulation rates and multiple sites of stimulation in the cochlea. Equipped with such a state-of-the-art system, the majority of recipients today can communicate orally without visual cues and can even use the telephone.
Outros nomes:
  • CI
  • Hearing implant

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Word Recognition Score in % correct over time
Prazo: Outcome measures will be assessed based on availablity of the respective data from pre-operative assessment through the following post-implantation follow-up periods: 6 weeks, 6 months, 1-, 2-, 5-, 10-, 15-, 20-years and last available follow-up.
The primary objective of this retrospective observational study is to evaluate speech performance in quiet over time of MED-EL cochlear implant users, measured as the percentage of words recognized correctly.
Outcome measures will be assessed based on availablity of the respective data from pre-operative assessment through the following post-implantation follow-up periods: 6 weeks, 6 months, 1-, 2-, 5-, 10-, 15-, 20-years and last available follow-up.

Outras medidas de resultado

Medida de resultado
Descrição da medida
Prazo
Speech Recognition Threshold in noise (SRT 50) measured in dB SNR over time
Prazo: Outcome measures will be assessed based on availablity of the respective data from pre-operative assessment through the following post-implantation follow-up periods: 6 weeks, 6 months, 1-, 2-, 5-, 10-, 15-, 20-years and last available follow-up.
SRT in noise is defined as the level difference in decibels (dB SNR) between speech signal and noise at which 50% (SRT50) of the words presented can be correctly identified. SNR is a measure of the relative levels of a desired signal (such as speech) compared to background noise. It is expressed in decibels (dB SNR) and indicates how much louder the signal is than the noise.
Outcome measures will be assessed based on availablity of the respective data from pre-operative assessment through the following post-implantation follow-up periods: 6 weeks, 6 months, 1-, 2-, 5-, 10-, 15-, 20-years and last available follow-up.
Speech, Spatial and Qualities of Hearing Scale (SSQ) 12
Prazo: Outcome measures will be assessed based on availablity of the respective data from pre-operative assessment through the following post-implantation follow-up periods: 6 weeks, 6 months, 1-, 2-, 5-, 10-, 15-, 20-years and last available follow-up.
The Speech, Spatial, and Qualities of Hearing Scale (SSQ12) questionnaire is a 12 item sensitive and specific measure to assess the impact of hearing loss on speech perception, sound localization, and QoL. The SSQ12 minimum score is 0, the maximum score is 120. The higher the score obtained, the lower the difficulty experienced by the patient.
Outcome measures will be assessed based on availablity of the respective data from pre-operative assessment through the following post-implantation follow-up periods: 6 weeks, 6 months, 1-, 2-, 5-, 10-, 15-, 20-years and last available follow-up.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de outubro de 2026

Conclusão Primária (Estimado)

1 de novembro de 2026

Conclusão do estudo (Estimado)

1 de novembro de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

11 de agosto de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

17 de agosto de 2026

Primeira postagem (Real)

20 de agosto de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

9 de setembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

7 de setembro de 2026

Última verificação

1 de setembro de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever