- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07798414
Randomized Clinical Trial of the Application of TrachPhone HME and the Impact on Patient Satisfaction for Tracheostomized Head and Neck Cancer Patients (HME)
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
The research on the TrachPhone HME for tracheostomized patients are limited (Kearney, et al, 2023). Furthermore, this research study is highly warranted to demonstrate that the use of an HME filter for tracheostomized patients improves pulmonary function and can even allow patients to voice, improving their quality of life.
The purpose of the use of Trachphone for tracheostomized head and neck cancer patients in the post-operative acute care setting to improve pulmonary rehabilitation, pulmonary function and improve patient satisfaction. The TrachPhone is a multifunctional HME providing heat and moisture, it has a speaking valve function, integrated oxygen supply port, integrated tracheal suctioning port allowing for tracheal suctioning without having to remove the HME, and foam filter.
Following surgery, eligible patients will be identified and approached by a Speech-Language Pathologist (SLP) during the post-operative period (days 1-3). Patients who express interest will be provided with a full explanation of the study, after which written informed consent will be obtained prior to enrollment. Enrolled participants will be randomly assigned to either the experimental or control group using a computer-generated randomization list. Participants will be assigned to groups sequentially in the order they are enrolled.
Randomized controlled clinical trial for 80 tracheostomized head and neck cancer patient within post operative day 1-3 (40 participants in the control group not using Trachphone and 40 participants in the experimental group with TrachPhone HME application).
Experimental Group (TrachPhone HME) Within post-operative days 1-3, participants assigned to the experimental group will be fitted with the TrachPhone Heat and Moisture Exchanger (HME), placed directly on the open tracheostomy. At enrollment, baseline data will be collected, including vital signs, completion of the Tracheostomy Wellbeing Score (TWS), and suctioning frequency as documented in the electronic health record (Epic). Participants will wear the TrachPhone continuously as tolerated, per nursing communication order. The SLP will conduct a follow-up assessment 1-2 days prior to or on the day of decannulation or discharge, at which time vital signs, TWS, and suctioning frequency will be reassessed.
Control Group (Standard Trach Collar).
Participants assigned to the control group will receive standard tracheostomy care with a trach collar in place. At enrollment, identical baseline measures will be collected, including vital signs, TWS completion, and suctioning frequency via Epic nursing documentation. Participants will wear the trach collar continuously as tolerated, per nursing communication order. The SLP will conduct a follow-up assessment 1-2 days prior to or on the day of decannulation or discharge, collecting the same outcome measures as baseline.
Procedures conducted is per standard of care assessing vitals of a tracheostomized patient. The procedures that will be conducted solely for the purpose of the study will be use of TrachPhone HME, monitoring frequency of required suctioning and vitals, and providing patient with a Tracheostomy Wellbeing Score.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Fase 2
- Fase 1
Contactos e Locais
Contato de estudo
- Nome: Jennifer T Larsson, MS, CCC-SLP
- Número de telefone: 9545522142
- E-mail: Jlarsson@usf.edu
Estude backup de contato
- Nome: Melanie Shaha, MS, CCC-SLP
- Número de telefone: 720-232-4585
- E-mail: melanieshaha@usf.edu
Locais de estudo
-
-
Florida
-
Tampa, Florida, Estados Unidos, 33626
- Tampa General Hospital
-
Tampa, Florida, Estados Unidos, 33626
- University of South Florida
-
Contato:
- Jennifer T Larsson, MS, CCC-SLP
- Número de telefone: 9545522142
- E-mail: Jlarsson@usf.edu
-
Contato:
- Melanie Shaha, MS, CCC-SLP
- Número de telefone: 720-232-4585
- E-mail: melanieshaha@usf.edu
-
Subinvestigador:
- Morgan Trubilla, MS, CCC-SLP
-
Subinvestigador:
- Tara Segalewitz, MS CCC-SLP
-
Subinvestigador:
- Ashley Thomas, MS, CCC-SLP
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- Patients over 18 years old with diagnosis of head and neck cancer who received a tracheostomy after their surgery in the acute care setting.
Exclusion Criteria:
- Patients with head and neck cancer who did not receive a tracheostomy in the post-operative period.
- Patients with tracheostomy on mechanical ventilation in the post-operative period.
- Patients who are unable to don on/off the TrachPhone HME.
- Patients who has a cuffed tracheostomy.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Experimental- Participants who will receive the TrachPhone HME
Within post-operative days 1-3, participants assigned to the experimental group will be fitted with the TrachPhone Heat and Moisture Exchanger (HME), placed directly on the open tracheostomy.
At enrollment, baseline data will be collected, including vital signs, completion of the Tracheostomy Wellbeing Score (TWS), and suctioning frequency as documented in the electronic health record (Epic).
Participants will wear the TrachPhone continuously as tolerated, per nursing communication order.
The SLP will conduct a follow-up assessment 1-2 days prior to or on the day of decannulation or discharge, at which time vital signs, TWS, and suctioning frequency will be reassessed.
|
The purpose of the use of Trachphone for tracheostomized head and neck cancer patients in the post-operative acute care setting to improve pulmonary rehabilitation, pulmonary function and improve patient satisfaction.
The TrachPhone is a multifunctional HME providing heat and moisture, it has a speaking valve function, integrated oxygen supply port, integrated tracheal suctioning port allowing for tracheal suctioning without having to remove the HME, and foam filter.
|
|
Comparador Ativo: Control group- Participants who will be provided standard of care for tracheostomy management
Participants assigned to the control group will receive standard tracheostomy care with a trach collar in place.
At enrollment, identical baseline measures will be collected, including vital signs, TWS completion, and suctioning frequency via Epic nursing documentation.
Participants will wear the trach collar continuously as tolerated, per nursing communication order.
The SLP will conduct a follow-up assessment 1-2 days prior to or on the day of decannulation or discharge, collecting the same outcome measures as baseline.
|
A tracheostomy collar (or trach collar) is a flexible plastic mask that fits over a tracheostomy tube in the neck to deliver humidified oxygen or room air to a patient who is breathing on their own
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
The effectiveness of Trachphone HME on both patient satisfaction as well as improved pulmonary function with tracheostomized head and neck cancer patients.
Prazo: From perioperative day 2 to day of hospital discharge day.
|
To describe the effectiveness of TrachPhone Heat Moisture Exchanger (HME) on patient satisfaction via completion of the completion of the Tracheostomy Wellbeing Score (TWS).
The Tracheostomy Well-Being Score (TWBS) is a 12-item patient-reported questionnaire designed to measure the impact of a tracheostomy on a patient's well-being across six key domains.
It is intended for use in critically ill patients and other tracheostomized individuals to assess subjective comfort and quality of life.
Each item is scored on a 4-point scale (0-3) based on frequency of occurrence (Never = 0, Sometimes = 1, Often = 2, Always = 3).
Higher total scores indicate greater perceived burden or discomfort.
|
From perioperative day 2 to day of hospital discharge day.
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
The effectiveness of Trachphone HME on both patient satisfaction as well as improved pulmonary function with tracheostomized head and neck cancer patients.
Prazo: From perioperative day 2 through day of hospital discharge day.
|
To describe the effectiveness of TrachPhone Heat Mositure Exchanger (HME) on pulmonary rehabilitation post-op for head and neck cancer patients by collecting data on vital signs (respiratory rate (RR) , heart rate (BPM) and oxygen saturation (SpO2) as well as suction frequency.
|
From perioperative day 2 through day of hospital discharge day.
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Jennifer Larsson, MS, CCC-SLP, University of South Florida
Publicações e links úteis
Links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- Study007731
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Tipo de informação de suporte de compartilhamento de IPD
- PROTOCOLO DE ESTUDO
- CSR
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .