Smartphone AI Assistance for Prehospital ECG Interpretation (ECG-IA)
AI & Prehospital ECG Analysis: A Randomized Controlled Trial of a Smartphone Large Language Model for Occlusion Myocardial Infarction Detection by Prehospital Providers
Prehospital providers interpret 12-lead electrocardiograms (ECGs) under time pressure and without immediate expert support. Missed acute coronary occlusion - occlusion myocardial infarction (OMI) - delays reperfusion, while false positive interpretations trigger unnecessary catheterization laboratory activations. Multimodal large language models (LLMs) available on any smartphone can now analyze a photographed ECG, and prehospital providers have begun using them spontaneously. No randomized trial has evaluated whether this practice improves diagnostic performance.
This randomized controlled trial compares the diagnostic performance of prehospital providers interpreting ECG clinical vignettes with and without mandatory assistance from a single, version-locked smartphone large language model. Participants - paramedics, emergency medical technicians, nurses and physicians practicing in prehospital care in French-speaking Switzerland - are randomized 1:1 on a dedicated digital platform and answer 14 clinical vignettes presented in individually randomized order. Each vignette is built around a real, anonymized 12-lead ECG obtained during routine clinical care.
The primary outcome is the proportion of vignettes for which the participant correctly identifies the presence or absence of an OMI. Secondary outcomes are sensitivity, specificity, and the accuracy of the prehospital priority decision level.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Design and setting. Two-arm parallel-group randomized controlled trial conducted on a dedicated digital platform. Phase 1 takes place during a single in-person session at the Swiss French-speaking prehospital clinical research conference (Morat, Switzerland, 2 September 2026). Phase 2 extends recruitment to prehospital emergency services across French-speaking Switzerland (September to November 2026) using an identical standardized protocol.
Randomization. Individual 1:1 allocation performed automatically by the platform using permuted blocks of variable size (4 to 6), without stratification, after the demographic questionnaire and before the first vignette. Allocation cannot be changed once assigned. The presentation order of the 14 vignettes is independently randomized for each participant, which neutralizes position effects and prevents copying between neighbouring participants.
Intervention. Participants allocated to the intervention arm must consult the study-imposed large language model for every vignette before submitting their answer; the platform locks the submit button until use of the tool is confirmed. A single model (OpenAI GPT-4o) in an API version locked for the entire study is used by all participants, with a standardized, non-modifiable prompt identical for every participant and every vignette. Participants cannot add text, ask follow-up questions, or provide additional clinical context. Exposure to the tool is mandatory, but adherence to its interpretation is not: participants remain free to base their final answer on their own clinical reasoning. Control participants interpret the same ECGs unaided, with smartphones turned face down and out of reach.
Reference standard. For each vignette, the expected answers were defined a priori by the study cardiologist and locked, with any subsequent modification time-stamped in the platform audit log. The reference standard is the answer expected of a prehospital provider at the point of care, anchored on coronary angiography wherever angiography is discriminant. For non-ischaemic mimics, the expected answer depends on whether the acute presentation allows the condition to be distinguished from a coronary occlusion: it does not for the Takotsubo case included in the study, whose expected answer is therefore "yes", whereas acute pericarditis, being usually recognizable, has an expected answer of "no". This pre-specified departure from a purely angiographic standard is reported as such, and the primary analysis is repeated in a sensitivity analysis in which all mimics are classified as non-OMI.
Blinding. Participants and investigators cannot be masked. The statistician conducting the primary analysis receives coded group labels only, and the allocation key is released after database lock and approval of the statistical analysis plan.
Statistical analysis. Mixed-effects logistic regression with correct OMI identification at vignette level as the dependent variable, arm as the main fixed effect, grouped ECG category as a fixed covariate, and random intercepts for participant and for vignette. Intention-to-treat, alpha 0.05 two-sided. The target is 130 evaluable participants (65 per arm), giving 80% power to detect an absolute increase from 0.65 to 0.80 with an intraclass correlation up to approximately 0.43. Allowing for approximately 10% of sessions to be abandoned before completion, planned enrollment is 144 (72 per arm).
ECG material. All tracings originate from routine clinical care at the Geneva University Hospitals, were selected by a cardiologist to cover predefined electrocardiographic categories, and were anonymized at source before transmission to the research team. No patient is enrolled, followed or contacted, and the research team holds no key allowing re-identification.
Pilot. A technical pilot involving a small number of prehospital providers was conducted before the study start date to test the platform. Pilot sessions took place outside the standardized study conditions and are identified in the database by a dedicated centre code; their data are excluded from all analyses, as pre-specified in the protocol.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: Laurent Bourgeois
- Número de telefone: +41 22 388 34 04
- E-mail: laurent.bourgeois@edu.ge.ch
Locais de estudo
-
-
Canton of Fribourg
-
Murten/Morat, Canton of Fribourg, Suíça, 3280
- Recrutamento
- Caserne des pompiers de Morat (Swiss French-speaking prehospital clinical research conference)
-
Contato:
- Laurent Bourgeois
- Número de telefone: +41 22 388 34 04
- E-mail: laurent.bourgeois@edu.ge.ch
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- Prehospital care provider practising in French-speaking Switzerland
- Any level of training: emergency medical technician, paramedic (ES), nurse (ES/HES) in prehospital emergency care, or prehospital emergency physician
- Electronic informed consent signed before randomization
Exclusion Criteria:
- Cardiologist
- Any person not practising in prehospital care
- Insufficient command of written French to answer the vignettes reliably
- Refusal to participate or withdrawal of consent
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Diagnóstico
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Solteiro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Sem intervenção: Control: unaided ECG interpretation
Participants interpret each of the 14 ECG vignettes without any assistance.
Smartphones are turned face down and out of reach for the duration of the session.
No intervention is administered.
|
|
|
Experimental: AI-assisted ECG interpretation
Participants must consult the study-imposed large language model for every vignette before submitting their answer.
The platform locks the submit button until use of the tool is confirmed.
Participants remain free not to follow the interpretation produced by the model and may base their final answer on their own clinical reasoning.
|
The platform transmits the ECG image to a single large language model (OpenAI GPT-4o, API snapshot gpt-4o-2024-08-06), locked for the entire study, together with a standardised prompt identical for all participants and all vignettes: "I am on an urgent prehospital call with a patient who presents this ECG.
Analyse it and tell me what you think."
Participants cannot modify the prompt, ask follow-up questions or provide additional clinical context.
The model version and system fingerprint returned by the API are recorded for every call.
The model's interpretation is displayed within the vignette.
Use of the tool is mandatory; adherence to its interpretation is not.
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Proportion of vignettes with correct identification of occlusion myocardial infarction (OMI) status
Prazo: Single study session, approximately 90 minutes; 14 vignettes per participant
|
For each of the 14 vignettes, the participant answers a binary question: "At this stage of care, is an OMI (acute coronary occlusion) likely?
Yes / No".
Responses are scored against a reference standard defined a priori, vignette by vignette, by the study cardiologist and locked before data collection.
This reference standard is the answer expected of a prehospital provider at the point of care, anchored on coronary angiography wherever angiography is discriminant.
For non-ischaemic mimics the expected answer depends on whether the acute presentation allows the condition to be distinguished from a coronary occlusion: it does not for the Takotsubo case (expected answer "yes"), whereas acute pericarditis is usually recognisable (expected answer "no").
This pre-specified departure from a purely angiographic standard is reported as such, and the analysis is repeated in a sensitivity analysis classifying all mimics as non-OMI.
The outcome is the proportion of correctly classified vignettes
|
Single study session, approximately 90 minutes; 14 vignettes per participant
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Sensitivity of OMI detection
Prazo: Single study session, approximately 90 minutes
|
Proportion of correctly identified OMI among vignettes whose expected answer is "yes", compared between arms.
Analysed by mixed-effects logistic regression restricted to these vignettes, with arm as fixed effect and a random intercept per participant.
|
Single study session, approximately 90 minutes
|
|
Specificity of OMI detection
Prazo: Single study session, approximately 90 minutes
|
Proportion of correctly identified non-OMI among vignettes whose expected answer is "no" (non-occlusive ischaemia, indeterminate ischaemia, recognisable non-ischaemic mimics, normal or non-specific ECGs), compared between arms.
Same modelling approach as for sensitivity.
|
Single study session, approximately 90 minutes
|
|
Accuracy of the prehospital priority decision level
Prazo: Single study session, approximately 90 minutes
|
Proportion of vignettes for which the participant selects the correct prehospital priority decision level, on a pre-specified five-level scale ranging from high-risk acute coronary syndrome with activation of the STEMI pathway to clearly non-cardiac symptoms.
The expected level is defined a priori for each vignette and locked before data collection.
|
Single study session, approximately 90 minutes
|
Outras medidas de resultado
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Diagnostic accuracy on the closed-list diagnosis question
Prazo: Single study session, approximately 90 minutes
|
For each vignette the participant selects a single diagnosis from a closed list of 86 items grouped in 8 families, using a filterable selector.
Two variables are produced automatically: exact match with the expected diagnosis, and match with the expected diagnosis or with any diagnosis pre-specified as clinically acceptable.
Reported descriptively by ECG category and by arm, then modelled by mixed-effects logistic regression if numbers allow.
The primary analysis uses the exact-or-acceptable variable; the strict variable is reported as a sensitivity analysis.
|
Single study session, approximately 90 minutes
|
|
Self-reported confidence and calibration
Prazo: Single study session, approximately 90 minutes
|
Confidence in the answer is reported by the participant for each vignette on a five-point Likert scale of self-reported diagnostic confidence, ranging from 1 (not at all confident) to 5 (very confident).
A higher score indicates greater self-reported confidence; confidence is a descriptive measure and a higher score is not in itself a better outcome.
Confidence is compared between arms by mixed-effects ordinal logistic regression.
Calibration is assessed as the concordance between reported confidence and the actual correctness of the answer, using calibration curves and the Brier score, which ranges from 0 to 1, a lower score indicating better calibration.
|
Single study session, approximately 90 minutes
|
|
Self-reported influence of the AI on the final answer
Prazo: Single study session, approximately 90 minutes
|
Degree to which the participant reports having been influenced by the model's interpretation, on a five-point Likert scale, collected for each vignette in the intervention arm only.
Analysed descriptively and in relation to the correctness of the answer.
No comparison between AI tools is conducted, the model version being fixed.
|
Single study session, approximately 90 minutes
|
|
Response time per vignette
Prazo: Single study session, approximately 90 minutes
|
Time from display of the vignette to submission of the answer, measured automatically in seconds by the platform.
Analysed by linear mixed-effects model on the log of the response time, with arm as fixed effect and a random intercept per participant; a sensitivity analysis compares individual median times between arms.
A longer time is expected in the intervention arm owing to consultation of the model, and is treated as a feasibility outcome for prehospital use.
|
Single study session, approximately 90 minutes
|
|
Diagnostic performance by level of training
Prazo: Single study session, approximately 90 minutes
|
Diagnostic performance according to the participant's level of training (emergency medical technician, paramedic, nurse, physician), and interaction between arm and level of training.
The study is not powered for this comparison and the distribution of training levels depends on spontaneous recruitment; results are hypothesis-generating and reported with confidence intervals only.
A minimum of 10 participants per category is required for separate analysis, failing which categories are pooled according to a rule documented before unblinding.
|
Single study session, approximately 90 minutes
|
Colaboradores e Investigadores
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
- precisão diagnóstica
- inteligência artificial
- apoio à decisão clínica
- eletrocardiografia
- OMI
- Suíça
- atendimento pré-hospitalar
- paramédicos
- Serviço de emergencia médica
- modelo de linguagem grande
- GPT-4o
- occlusion myocardial infarction
- clinical vignettes
- French-speaking Switzerland
- prehospital providers
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- ECG-IA-2026
- 2026-01430 (Outro identificador: Cantonal Research Ethics Committee of Geneva (CCER) - BASEC)
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Descrição do plano IPD
Prazo de Compartilhamento de IPD
Critérios de acesso de compartilhamento IPD
Tipo de informação de suporte de compartilhamento de IPD
- PROTOCOLO DE ESTUDO
- SEIVA
- CIF
- ANALYTIC_CODE
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .