- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07860567
Clinical Evaluation of Visual Performance, Spectacle Independence, and Patient Satisfaction With TECNIS PureSee Mini-Monovision and TECNIS PureSee-TECNIS Odyssey Mix-Match
The purpose of the study is to evaluate the binocular clinical endpoints of distance, intermediate, and near vision and patient reported outcomes utilizing mini-monovision versus mix-match approaches for the correction of presbyopia with intraocular lenses.
Visão geral do estudo
Status
Descrição detalhada
Presbyopia, defined as the age-related loss of accommodative amplitude, affects essentially all human beings beyond the age of 45 and impacts the ability of the eye to focus at near distances. Current intraocular lens (IOL) options for cataract patients who desire improved vision across a range of distances include full depth of field (DOFi) IOLs and extended depth of field (EDOF) IOLs. Patients implanted with full depth of field IOLs may sometimes experience dysphotopsias (e.g., glare and halos), particularly at night.
The goal with the correction of presbyopia is to maximize near visual range while minimizing the dysphotopsia profile. Bilateral implantation of extended depth of field lenses with a mini-monovision aim is one way to achieve this goal. EDOF lenses minimize the dysphotopsia profile and a near aim in the non-dominant eye will maximize the near visual range. Another option to achieve this goal is the mix-match approach with EDOF and a DOFi lens. The EDOF IOL minimizes the dysphotopsia profile while DOFi IOL maximizes the near visual range.
The hypothesis is that the mini-monovision and mix-match group will have equivalent uncorrected intermediate visual acuities. The mini-monovision group will have superior visual symptoms and the mix-match group will have superior uncorrected distance and near visual acuity, and spectacle independence.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Fase 4
Contactos e Locais
Contato de estudo
- Nome: Brittany Camirand, BSc, CCRC, COA
- Número de telefone: 203 661-325-3937
- E-mail: bcamirand@empireeyeandlaser.com
Estude backup de contato
- Nome: Isabelle Edgington, COA
- Número de telefone: 203 661-325-3937
- E-mail: iedgington@empireeyeandlaser.com
Locais de estudo
-
-
California
-
Bakersfield, California, Estados Unidos, 93309
- Empire Eye and Laser Center
-
Investigador principal:
- Daniel H Chang, MD
-
Subinvestigador:
- Andrew A Kao, MD
-
Subinvestigador:
- Laura K Huggins, OD
-
Subinvestigador:
- Jacqueline N Albert, OD
-
Contato:
- Brittany Camirand, BSc, CCRC, COA
- Número de telefone: 203 661-325-3937
- E-mail: bcamirand@empireeyeandlaser.com
-
Contato:
- Isabelle Edgington, COA
- Número de telefone: 203 661-325-3937
- E-mail: iedgington@empireeyeandlaser.com
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Minimum 22 years of age
- Bilateral cataracts for which posterior chamber IOL implantation has been planned
- Preoperative best corrected distance visual acuity (BCDVA) of 20/40 Snellen or worse with a glare source or 20/40 Snellen or worse without a glare source
- Potential for postoperative BCDVA of 20/30 Snellen or better
- Corneal astigmatism:
- Normal corneal topography
- Preoperative corneal astigmatism range from 0 D - 2.0 D
- Expected post-operative astigmatism < 1.0 D
- Clear intraocular media other than cataract in each eye
- Availability, willingness, and sufficient cognitive awareness to comply with examination procedures
- Signed informed consent and HIPAA authorization or equivalent documentation necessary to comply with applicable privacy laws pertaining to medical treatment in the governing countries
- Ability to understand and respond to a questionnaire in English
Exclusion Criteria:
- Requiring an intraocular lens power outside the available range of power
- Any clinically significant pupil abnormalities (non-reactive, fixed pupils, or abnormally shaped pupils)
- Irregular corneal astigmatism
- Inability to focus or fixate for prolonged periods of time (e.g., due to strabismus, nystagmus, etc.)
- Prior corneal refractive surgery (SMILE, LASIK, LASEK, RK, PRK, etc.) or intraocular surgery. Note: Prophylactic peripheral iridotomies and peripheral laser retinal repairs that, in the opinion of the investigator will not confound study outcomes or increase risk to the subject, are acceptable.
- Corneal abnormalities such as stromal, epithelial, or endothelial dystrophies that are predicted to cause visual acuity losses to a level worse than 20/30 Snellen during the study
- Inability to achieve keratometric stability for soft contact lens wearers
- History of PMMA or RGP contact lens wear within the last 5 years
- Recent ocular trauma or ocular surgery that is not resolved/stable or may affect visual outcomes or increase risk to the subject
- Subject with conditions associated with increased risk of zonular rupture, including capsular or zonular abnormalities that may lead to IOL decentration or tilt, such as pseudoexfoliation, trauma, or posterior capsule defects
- Use of systemic or ocular medications that may affect vision
- Prior, current, or anticipated use during the course of the 3 month study of tamsulosin or silodosin (e.g., Flomax, Flomaxtra, Rapaflo) that may, in the opinion of the investigator, confound the outcome or increase the risk to the subject (e.g., poor dilation or a lack of adequate iris structure to perform standard cataract surgery)
- Poorly controlled diabetes
- Acute, chronic, or uncontrolled systemic or ocular disease or illness that, in the opinion of the investigator, would increase the operative risk or confound the outcome(s) of the study (e.g., immunocompromised, connective tissue disease, glaucomatous changes in the fundus or visual field, ocular inflammation, etc.). Note: controlled ocular hypertension without glaucomatous changes (optic nerve cupping and visual field loss) is acceptable.
- Known ocular disease or pathology that, in the opinion of the investigator,
- may affect visual acuity
- may require surgical intervention during the course of the study (macular degeneration, cystoid macular edema, diabetic retinopathy, uncontrolled glaucoma, etc.)
- may be expected to require retinal laser treatment or other surgical intervention during the course of the study (macular degeneration, cystoid macular edema, diabetic retinopathy, etc.)
- Patient is pregnant, plans to become pregnant, is lactating or has another condition associated with the fluctuation of hormones that could lead to refractive changes
- Concurrent participation or participation within 60 days prior to preoperative visit in any other clinical trial
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Dobro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Mini-Monovision (TECNIS PureSee)
Participants will receive bilateral TECNIS PureSee IOLs (Model DEN00V/DET150), with the non-dominant eye targeted for a "second minus" near aim to achieve mini-monovision. |
Bilateral implantation of the TECNIS PureSee intraocular lens following standard phacoemulsification cataract surgery. The non-dominant eye is intentionally targeted for a "second minus" near focus strategy (mini-monovision). Implantation of the TECNIS PureSee intraocular lens into the dominant eye following standard phacoemulsification cataract surgery. |
|
Experimental: Mix-Match (TECNIS PureSee + TECNIS Odyssey)
Participants will receive a TECNIS PureSee IOL (Model DEN00V/DET150) in their dominant eye and a TECNIS Odyssey IOL (Model DRN00V/DRT150) in their non-dominant eye. |
Bilateral implantation of the TECNIS PureSee intraocular lens following standard phacoemulsification cataract surgery. The non-dominant eye is intentionally targeted for a "second minus" near focus strategy (mini-monovision). Implantation of the TECNIS PureSee intraocular lens into the dominant eye following standard phacoemulsification cataract surgery. Implantation of the TECNIS Odyssey intraocular lens into the non-dominant eye following standard phacoemulsification cataract surgery. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Binocular UCDVA
Prazo: At 3-month postoperative study visit
|
Binocular Uncorrected Distance Visual Acuity |
At 3-month postoperative study visit
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Binocular UCIVA
Prazo: At 3-month postoperative study visit
|
Binocular Uncorrected Intermediate Visual Acuity |
At 3-month postoperative study visit
|
|
Binocular UCNVA
Prazo: At 3-month postoperative study visit
|
Binocular Uncorrected Near Visual Acuity |
At 3-month postoperative study visit
|
|
Patient Reported Outcomes PRVSQv2
Prazo: At 3-month postoperative study visit
|
Patient Reported Outcomes (as recorded by the PRVSQ2 questionnaire). The questionnaire does not generate a scale-based or indexed score. Results are analyzed descriptively, capturing the frequency and distribution of specific visual complaints reported across the study population. |
At 3-month postoperative study visit
|
|
Patient Reported Outcomes PRSIQv2
Prazo: At 3-month postoperative study visit.
|
Patient Reported Outcomes (as recorded by the PRSIQ2 questionnaire). The questionnaire does not generate a scale-based or indexed score. Results are analyzed descriptively, capturing the frequency and distribution of specific visual complaints reported across the study population. |
At 3-month postoperative study visit.
|
Outras medidas de resultado
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Residual Refractive Error
Prazo: At 3-month postoperative study visit
|
Residual Refractive Error |
At 3-month postoperative study visit
|
|
Halometry
Prazo: At 3-month postoperative study visit
|
Dysphotopsias Measured by Clinical Halometry |
At 3-month postoperative study visit
|
|
Spectacle Use
Prazo: At 3-month postoperative study visit
|
Patient Reported Spectacle Use |
At 3-month postoperative study visit
|
|
Other Ocular/Visual Symptoms
Prazo: At 3-month postoperative study visit
|
Unsolicited visual or eye-related complaints volunteered by participants rather than specifically probed by the investigator. Serves as a secondary safety or tolerability measure to monitor unexpected sensory side effects. Quantified via non-leading, open-ended questioning during study visits or via non-directed adverse event logging |
At 3-month postoperative study visit
|
|
Patient Recommendation and Satisfaction
Prazo: At 3-month postoperative study visit
|
Patient Recommendation and Satisfaction (as recorded by the PQRS questionnaire). The questionnaire does not generate a scale-based or indexed score. Results are analyzed descriptively, capturing the frequency and distribution of specific visual complaints reported across the study population. |
At 3-month postoperative study visit
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Diretor de estudo: Daniel H Chang, MD, Empire Eye and Laser Center
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- EMP-2026-001
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .