Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Use of Various Types of Introducers in Conventional Radial Access (TIRE)

8 мая 2026 г. обновлено: Aleksandr V. Bocharov, PhD, MD, Pirogov Russian National Research Medical University

The purpose of this intervention study is to compare different types of radial introducers used in traditional radial access in terms of the incidence of complications.

The main questions it aims to answer are:

  1. Does a smaller outer diameter of the introducer reduce the risk of complications associated with radial access?
  2. Does the presence of an outer hydrophilic coating on the introducer reduce the risk of complications associated with radial access?
  3. Does the use of an introducer with a smaller outer diameter and an outer hydrophilic coating reduce the risk of complications associated with radial access? The researchers will compare the number of complications associated with radial access when using conventional diameter, uncoated radial introducers, conventional diameter introducers with an outer hydrophilic coating, or reduced outer diameter introducers with an outer hydrophilic coating.

During the scheduled revascularization procedure, the participants will undergo radial artery catheterization using one of the types of introducers. Complications from the radiation access will be recorded by doctors within 72 hours after the intervention.

Обзор исследования

Подробное описание

Objective: to compare different types of radial introducers used in conventional radial access by the frequency of complications.

Scientific hypotheses:

  1. The risk of acute radial artery occlusion depends on the outer diameter of the introducer.
  2. The risk of acute radial artery occlusion depends on the presence of an outer hydrophilic coating on the introducer.
  3. The risk of persistent radial artery spasm depends on the presence of an outer hydrophilic coating on the introducer.
  4. The risk of persistent radial artery spasm depends on the outer diameter of the introducer.

Patients were enrolled by endovascular specialists with experience of at least 250 radial-access procedures per year.

Inclusion criteria: clear pulsation of the right radial artery, indications for percutaneous coronary intervention.

Exclusion criteria: previous unsuccessful radial artery catheterization; concomitant pathology limiting patient survival; disorders of the blood coagulation system (hemophilia, thrombocytopathy, etc.); previous coronary artery bypass grafting; occlusion of the right radial artery.

The required sample size was calculated using the method of M. Bland for a high-precision study. The required significance level (α) was 0.001 and the statistical power was 95%. The expected rate of radial artery occlusion in the Rad, Rad polymer, and Rad slender groups was assumed to be 12%, 8%, and 8%, respectively. Under these conditions, the calculated sample size was 2723 patients. The planned loss during the study was 20%. Thus, the minimum sample size was 3268 patients.

The study had an experimental design and complied with the CONSORT protocol. A simple randomization method using a random-number generator was chosen. The type of randomization was permuted block randomization. The total block size was 3000, and the allocation ratio between the groups was 1:1:0.7.

Puncture of the right radial artery was performed after local anesthesia with a 2% lidocaine solution. The radial artery was punctured at the typical site using the puncture needle included in the introducer set, with only the anterior wall being punctured. The type of introducer was selected by randomization using a random-number method, and depending on this assignment the patient was allocated to one of the groups.

All patients underwent percutaneous coronary angioplasty with coronary artery stenting via the right radial artery. The radial artery catheterization technique did not differ between groups. The type of introducer was selected by randomization using a random-number method, and depending on this assignment the patient was allocated to one of the groups. In the Rad group , introducers without a hydrophilic coating were used; in the Rad polymer group , introducers with a hydrophilic coating were used; and in the Rad slender group , thin-walled introducers with a hydrophilic coating were used. The access site was examined within 3 hours after the intervention and then, in the absence of complaints, again at bandage removal. After bandage removal, patients underwent ultrasound examination to confirm radial artery patency. Complications from the radiation access will be recorded by doctors within 72 hours after the intervention.

Тип исследования

Интервенционный

Регистрация (Действительный)

3307

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

    • Kostroma Oblast
      • Kostroma, Kostroma Oblast, Россия, 156013
        • E.I. Korolev Kostroma Regional Clinical Hospital
    • Moscow
      • Moscow, Moscow, Россия, 119071
        • Central Clinical Hospital of St. Alexy Metropolitan of Moscow of the Moscow Patriarchate of the Russian Orthodox Church

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Взрослый
  • Пожилой взрослый

Принимает здоровых добровольцев

Нет

Описание

Inclusion Criteria:

  • clear pulsation of the right radial artery
  • indications for percutaneous coronary intervention

Exclusion Criteria:

  • previous unsuccessful radial artery catheterization
  • concomitant pathology limiting patient survival
  • disorders of the blood coagulation system (hemophilia, thrombocytopathy, etc.)
  • previous coronary artery bypass grafting
  • occlusion of the right radial artery

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Поддерживающая терапия
  • Распределение: Рандомизированный
  • Интервенционная модель: Параллельное назначение
  • Маскировка: Двойной

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Активный компаратор: Rad classic
Introducer with a standard outer diameter and no external hydrophilic coating

The right radial artery was punctured under local anesthesia with a 2% lidocaine solution. The radial artery was punctured at a typical location using a puncture needle included in the catheterization kit, puncturing only the anterior wall.

An introducer with a standard outer diameter and no external hydrophilic coating was inserted.

5,000 IU of heparin in saline solution was injected into the catheterized artery. All injected solutions, including radiocontrast agents, had a temperature of 36.5-36.7 °C. Hemostasis was achieved by applying a pressure bandage.

The access site was examined 3 hours after the intervention, and then, if there were no complaints, it was examined again when the bandage was removed. After the bandage was removed, patients underwent an ultrasound examination to confirm the patency of the radial artery.

Complications were recorded within 3 days after the intervention.

Экспериментальный: Rad polymer
Introducer with a standard outer diameter and an outer hydrophilic coating

Description: The right radial artery was punctured under local anesthesia with a 2% lidocaine solution. The radial artery was punctured at a typical location using a puncture needle included in the catheterization kit, puncturing only the anterior wall.

An introducer with a standard outer diameter and an outer hydrophilic coating was using.

5,000 IU of heparin in saline solution was injected into the catheterized artery. All injected solutions, including radiocontrast agents, had a temperature of 36.5-36.7 °C. Hemostasis was achieved by applying a pressure bandage. The access site was examined 3 hours after the intervention, and then, if there were no complaints, it was examined again when the bandage was removed. After the bandage was removed, patients underwent an ultrasound examination to confirm the patency of the radial artery. Complications were recorded within 3 days after the intervention.

Экспериментальный: Rad slender
Introducer with a reduced outer diameter and an outer hydrophilic coating

Description: The right radial artery was punctured under local anesthesia with a 2% lidocaine solution. The radial artery was punctured at a typical location using a puncture needle included in the catheterization kit, puncturing only the anterior wall.

An introducer with a reduced outer diameter and an outer hydrophilic coating was using.

5,000 IU of heparin in saline solution was injected into the catheterized artery. All injected solutions, including radiocontrast agents, had a temperature of 36.5-36.7 °C. Hemostasis was achieved by applying a pressure bandage. The access site was examined 3 hours after the intervention, and then, if there were no complaints, it was examined again when the bandage was removed. After the bandage was removed, patients underwent an ultrasound examination to confirm the patency of the radial artery. Complications were recorded within 3 days after the intervention.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Acute radial artery occlusion after catheterization
Временное ограничение: Within 72 hours after radial artery catheterization
Acute radial artery occlusion was confirmed by ultrasound examination
Within 72 hours after radial artery catheterization
Radial artery perforation
Временное ограничение: Perioperative/Periprocedural
Angiography-confirmed perforation of the radial artery
Perioperative/Periprocedural
Radial artery false aneurysm
Временное ограничение: Within 72 hours after radial artery catheterization
A false aneurysm of the radial artery was confirmed by ultrasound examination
Within 72 hours after radial artery catheterization
Hematoma by classification EASY Grade II
Временное ограничение: Within 72 hours after radial artery catheterization
Hematoma by classification EASY Grade II was confirmed by ultrasound examination
Within 72 hours after radial artery catheterization
Persistent radial artery spasm
Временное ограничение: Perioperative/Periprocedural
Persistent radial artery spasm confirmed by angiography
Perioperative/Periprocedural

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

28 января 2019 г.

Первичное завершение (Действительный)

16 декабря 2025 г.

Завершение исследования (Действительный)

19 декабря 2025 г.

Даты регистрации исследования

Первый отправленный

22 апреля 2026 г.

Впервые представлено, что соответствует критериям контроля качества

6 мая 2026 г.

Первый опубликованный (Действительный)

7 мая 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

13 мая 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

8 мая 2026 г.

Последняя проверка

1 мая 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

ДА

Описание плана IPD

all personal data underlying the publication results

Сроки обмена IPD

Beginning 6 months and ending 1 years after the publication of results

Совместное использование IPD Поддерживающий тип информации

  • STUDY_PROTOCOL
  • САП
  • КСО

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться