Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Comparing 3D-Printed and Milled Titanium Plates in Jaw Surgery (Le Fort I): Accuracy and Operative Time (TiPlateRCT)

19 сентября 2026 г. обновлено: Mohamed Ashraf Mohamed Mohamed Khedre, Future University in Egypt

Assessment of the Three-Dimensional Surgical Accuracy and Operative Time of 3D-Printed Versus Milled Patient-Specific Titanium Plates in Le Fort I Osteotomy: A Randomized Clinical Trial

The purpose of this study is to find out if 3D printed patient-specific titanium plates improve surgical accuracy and decrease operative time compared to milled patient-specific titanium plates in patients having Le Fort I osteotomy for jaw correction. The main questions it aims to answer are:

  • Do 3D-printed patient specific titanium plates improve surgical accuracy (as measured by ability to transfer the computer plan to the patient's jaw)?
  • Do 3D-printed patient specific titanium plates decrease operative time when compared to milled patient specific titanium plates? This study will compare two groups of patients. One group will receive 3D printed plates (study group) and the other will receive milled plates (control group) to see if the different methods of making the plates changes the surgical accuracy or operative time.

All participants in the study will:

  • Have Le Fort I osteotomy surgery using patient specific titanium plates (either 3D printed or milled).
  • Have CT scans before and after surgery to evaluate accuracy. Have their operative time recorded.
  • Have a post-surgical follow-up to evaluate healing, stability and orthodontic treatment.

Обзор исследования

Подробное описание

  • Background and Clinical Rationale Orthognathic surgeries, specifically Le Fort I osteotomy, requires precise transfer of the virtual surgical plan to the operative field to achieve predictable functional and facial outcomes. Conventional splint-based fixation techniques may introduce cumulative inaccuracies arising from laboratory fabrication errors, intraoperative handling, and manual plate adaptation. To overcome these limitations, computer-aided design and computer-aided manufacturing (CAD/CAM) workflows allow for the fabrication of patient-specific titanium plates via 3D printing (additive manufacturing) or milling (subtractive manufacturing). While both fabrication methods aim to enhance surgical accuracy and workflow efficiency, direct randomized controlled trial evidence comparing the three-dimensional accuracy and operative performance of 3D-printed versus milled maxillary patient-specific plates remains limited.

  • Preoperative Diagnostic Protocol & 3D Virtual Surgical Planning

    1. Presurgical Orthodontic & Diagnostic Setup: Participants undergo presurgical orthodontic treatment for dental decompensation to establish a stable occlusion in at least three points. Preoperative diagnostic records include standardized facial and dental photographs along with dental casts obtained from alginate impressions.
    2. Image Acquisition & 3D Skull Reconstruction: Computed Tomography (CT) scans are acquired in the natural head position utilizing a Planmeca ProFace imaging machine. Diagnostic dental models are digitized using an optical scanner (Shera operating system 7Series; Dental Wing Inc., Montreal, Quebec, Canada). The digitized dental models will be manipulated using point-based matching iterative closest point (ICP) registration based on anatomical landmarks followed by manual surface-based registration to generate an artifact-free composite 3D skull model.
    3. Surgical Simulation & Guide Design: 3D cephalometric analysis of the bony and soft tissue landmarks are conducted using surgical simulation software (Mimics 19.0; Materialise NV, Leuven, Belgium). Virtual Le Fort I osteotomy and mandibular sagittal split osteotomy (SSO) are simulated, adjusting the maxillary segment relative to facial symmetry planes and clinical anthropometric analysis. The cutting guides will be designed on the maxilla to orient the osteotomy and mark reference holes (16 holes with 8 holes on each side) to be used later for the repositioning/ fixation plate, using CAD software (3-matic 11.0; Materialise NV, Leuven, Belgium).
    4. CAD/CAM Manufacturing:

Surgical Guides: Exported in stereolithography (STL) file format and printed in white polyamide (PA2200; EOS e-manufacturing solutions, Munich, Germany) via fused deposition modeling (FDM) on an additive CAM machine (FORMIGA P 110 printer; EOS e-manufacturing solutions, Munich, Germany). The guides are cold-sterilized by overnight immersion in 2% glutaraldehyde.

Patient-Specific Osteosynthesis Plates: Designed to fix the maxilla in the desired position making use of the previously established reference holes. The designed plates will be exported in STL file format to be manufactured in grade 5 titanium alloy using either 3D printing or milling according to randomized allocation .

Intraoperative Protocol & Interventions Surgical procedures are performed under general anesthesia then intraoral local anesthetic infiltration along incision line with (lidocaine 2%, 1/100,000 adrenaline) for hemostasis. Access is established via intraoral vestibular maxillary and sagittal split mandibular incisions.

Osteotomy & Reference Hole Drilling: The maxillary cutting guide is seated on the exposed bone, verified for passive fit, and secured using four 2.0-mm screws. Sixteen reference holes (8 per side) are established through the guide. A reciprocating saw is used to perform the Le Fort I osteotomy, followed by maxillary mobilization and removal of bony interferences. Bilateral sagittal split osteotomies of the mandible are subsequently performed using a mandibular guide.

Fixation Protocol (Randomized Allocation):

Study Arm (Group 1): Maxillary repositioning and fixation are executed using 3D-printed patient-specific titanium plates, aligned with the pre-established reference holes and secured with 2.0-mm screws.

Control Arm (Group 2): Maxillary repositioning and fixation are executed using milled patient-specific titanium plates, aligned with the pre-established reference holes and secured with 2.0-mm screws.

Mandibular Fixation & Closure: In both arms, the mandible is repositioned and fixated relative to the maxilla using traditional tri-poding bi-cortical screws. Incisions are sutured using 4-0 resorbable sutures in a continuous running fashion.

Postoperative Care & Evaluation Schedule Postoperative Medications: Systemic antibiotic coverage (Amoxicillin / Clavulanic acid 625 mg every 8 hours) is initiated 4 hours postoperatively and continued for 5 days. Analgesics (NSAIDs every 6 hours) are provided for 3 days, and 0.12% Chlorhexidine mouthwash is prescribed for 2 weeks.

Follow-Up Schedule: Clinical evaluations occur weekly for the first month, followed by monthly visits for 5 additional months.

Radiographic Evaluation & Orthodontics: A postoperative CT scan is acquired within the first postoperative week using parameters identical to the baseline scan to analyze 3D plan transfer accuracy. Post-surgical orthodontic treatment resumes 4 to 6 weeks postoperatively.

Quality Assurance, Monitoring, and Auditing Supervision & Governance: All CAD/CAM virtual planning and surgical procedures are conducted under the direct supervision of senior academic staff (Prof. Lobna Abdelaziz Aly and Dr. Aya Magdy AbdelRady) at the Oral and Maxillofacial Surgery Department, Future University in Egypt.

Harms: Any temporary or permanent adverse effect will be recorded and documented.

Auditing: Auditing of the study design will be done by the Research Ethics Council, Future University in Egypt.

Protocol Amendments: Any modifications impacting study conduct, patient safety, or benefits require formal approval by the Council of the Oral and Maxillofacial Surgery Department, Future University in Egypt.

Discontinuation Criteria: Interventions are discontinued if technical difficulty with cutting guides/plates arises or if inaccurate translation of the surgical plan occurs intraoperatively.

Confidentiality: All study-related information will be stored securely. All participant information will be stored in locked file cabinets in areas with limited access. All patients' records will be digitized and stored securely on personal computer.

Ancillary and Post Trial Care: All patients will be followed up until complete healing and satisfactory results occur.

Declaration of interests: The study is self-funded. No conflict of interest Consent: The entire procedure will be explained to the patients and a written consent will be obtained.

Standard Operating Procedures & Protocol Workflows

  1. Patient Recruitment & Consent:

    Inclusion criteria target skeletally mature patients requiring Le Fort I osteotomy for Class II/III malocclusion with good oral hygiene and no active TMDs.

    Fully informed written consent is obtained prior to enrollment.

  2. CAD/CAM & Manufacturing:

    Preoperative CT scans and digitized dental models. Cutting guides and Patient-specific titanium plates (Grade 5 titanium alloy) are manufactured.

  3. Intraoperative Fixation Procedures

  4. Postoperative Care & Follow-Up

  5. Adverse Event (Harms) Reporting:

Any temporary or permanent adverse effects occurring during the trial are documented and recorded in patient files.

Plan for Missing Data & Participant Retention Participant Retention Strategies: Patient phone numbers are recorded during written consent, and structured telephone reminders are made prior to every follow-up visit.

Adherence Verification: Patients are recalled at 1-week intervals and instructed to bring their medication packaging to verify postoperative drug compliance.

Statistical Analysis Plan Statistical analysis will be carried out. Data will be analyzed using IBM SPSS advanced statistics (Statistical Package for Social Sciences), version 21 (SPSS Inc., Chicago, IL). Numerical data will be described as mean and standard deviation or median and range, as appropriate. Because of the small sample size, the comparisons between pre and post treatment will be done by Wilcoxon signed rank test. A p-value less than or equal to 0.05 will be considered statistically significant. All tests will be two tailed.

Тип исследования

Интервенционный

Регистрация (Оцененный)

12

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

    • New Cairo, Fifth Settlement
      • Cairo, New Cairo, Fifth Settlement, Египет, 11835
        • Рекрутинг
        • Oral and Maxillofacial Surgery Department, Faculty of Oral and Dental Medicine, Future University in Egypt
        • Контакт:
          • Mohamed A Khedre, BDS, MSc candidate
          • Номер телефона: +201091102408
          • Электронная почта: 20253897@fue.edu.eg
        • Главный следователь:
          • Mohamed A Khedre, BDS, MSc candidate
        • Младший исследователь:
          • Lobna Abdelaziz, Prof. Dr.
        • Младший исследователь:
          • Aya Magdy, Dr.

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

18 лет и старше (Взрослый, Пожилой взрослый)

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

  • Skeletally mature patients (typically ≥ 18 years old) with fused growth plates.
  • Non-syndromic skeletal Class II or Class III malocclusion requiring a Le Fort I osteotomy (with or without mandibular involvement).
  • Patients with no signs or symptoms of active temporomandibular disorders (TMD).
  • Patients with good oral hygiene and no active periodontal disease that could affect tooth-borne guides.
  • Highly motivated patients.

Exclusion Criteria:

  • Patients who refused to be included in the research and patients unable to comply with follow up Protocol.
  • Patients with systemic diseases may hinder the normal healing process or render the patient not fit for general anesthesia.
  • Craniofacial anomalies or syndromes (cleft lip/palate, syndromic deformities).
  • Previous orthognathic surgery or revision cases.
  • Patients with intra-bony lesions or infections that may retard the osteotomy healing.
  • History of maxillofacial trauma altering anatomy.

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Уход
  • Распределение: Рандомизированный
  • Интервенционная модель: Параллельное назначение
  • Маскировка: Одинокий

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: 3D-Printed Patient-Specific Titanium Plates

Participants in this group undergo Le Fort I osteotomy with maxillary repositioning and fixation using 3D-printed (additive manufactured) patient-specific grade 5 titanium alloy plates. Plate placement is guided by pre-drilled reference holes established via CAD/CAM cutting guides and secured with 2.0-mm screws.

Following a Le Fort I osteotomy performed with a reciprocating saw, the maxilla is repositioned and rigidly fixated using the 3D-printed patient-specific plates. Plate alignment is guided by 16 pre-drilled reference holes (8 per side) established using a customized cutting guide, and plates are secured using 2.0-mm screws

Активный компаратор: Milled Patient-Specific Titanium Plates

Participants in this group undergo Le Fort I osteotomy with maxillary repositioning and fixation using milled (subtractive manufactured) patient-specific grade 5 titanium alloy plates. Plate placement is guided by pre-drilled reference holes established via CAD/CAM cutting guides and secured with 2.0-mm screws.

Following a Le Fort I osteotomy performed with a reciprocating saw, the maxilla is repositioned and rigidly fixated using the milled patient-specific plates. Plate alignment is guided by the same 16 pre-drilled reference holes (8 per side) established via a customized cutting guide, and plates are secured using 2.0-mm screws

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Accuracy of Surgical Transfer
Временное ограничение: Immediate postoperative period (within the first week postoperatively)

The primary outcome measures the precision with which the virtual surgical plan (P0/T0) is transferred to the actual surgical outcome (P1/T1).

  • Image Registration: The virtual surgical plan is superimposed onto the postoperative Computed Tomography (CT) scan using point-based matching Iterative Closest Point (ICP) registration, followed by manual surface-based best-fit registration targeting the stable skull base in Mimics 19.0 software.
  • Linear Measurement: Discrepancies between the planned and actual positions are measured from hard tissue reference points specifically the upper central incisor (U1) and upper first molars (16, 26):

Vertical Deviation: Distance measured relative to the Frankfort Horizontal Plane (FHP).

Anteroposterior Deviation: Distance measured relative to the Coronal Plane (CP).

Mediolateral Deviation: Distance measured relative to the Mid-Facial Plane (MFP).

Immediate postoperative period (within the first week postoperatively)

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Operative Time
Временное ограничение: Intraoperatively (from initial surgical incision to final suture closure)

Operative time is defined as the total intraoperative duration required for all surgical procedures, including the positioning and fixation of the patient-specific titanium plate on the maxilla during Le Fort I osteotomy. The time is measured and recorded in minutes for each participant using a digital stopwatch, starting when the surgeon performs the first surgical incision and ending when the surgeon completes final closure suturing

Intraoperatively (from initial surgical incision to final suture closure)
Postoperative Stability
Временное ограничение: Immediate postoperative period (within 1 week postoperatively)

Evaluates the extent to which skeletal structures maintain their corrected position relative to the virtual surgical plan following Le Fort I osteotomy. Postoperative CT scans obtained within 1 week are imported into Mimics software and superimposed onto the virtual plan using stable skull base reference points. Linear deviations are evaluated at key hard tissue landmarks (central incisor U1, first molars 16 and 26) across three spatial dimensions

Immediate postoperative period (within 1 week postoperatively)

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Публикации и полезные ссылки

Лицо, ответственное за внесение сведений об исследовании, добровольно предоставляет эти публикации. Это может быть что угодно, связанное с исследованием.

Общие публикации

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Оцененный)

1 октября 2026 г.

Первичное завершение (Оцененный)

1 декабря 2026 г.

Завершение исследования (Оцененный)

1 апреля 2027 г.

Даты регистрации исследования

Первый отправленный

19 сентября 2026 г.

Впервые представлено, что соответствует критериям контроля качества

19 сентября 2026 г.

Первый опубликованный (Действительный)

25 сентября 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

25 сентября 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

19 сентября 2026 г.

Последняя проверка

1 сентября 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕ РЕШЕНО

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

продукт, произведенный в США и экспортированный из США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться