Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Clinical Assessment of Dynamic and Static Occlusal Contacts in Direct and Indirect Posterior Restorations

7 октября 2026 г. обновлено: Marmara University

Conventional clinical evaluation of dental occlusion relies predominantly on qualitative indicators such as articulating papers, metallic foils, and silicone-based materials and the accuracy of these indicators may be influenced by material thickness, moisture contamination, and subjective interpretation. Quantitative assessment of occlusal contacts in direct and indirect posterior restorations may help clinicians to establish and maintain harmonious and proper dental occlusion. To assess the level of static and dynamic occlusal contact surfaces in direct and indirect restorations, clinically and quantitatively. Also, to compare outcomes between clinicians with two different levels of clinical experience, immediately and one month after the restorative procedures. Patients requiring restoration for maxillary or mandibular first molars were treated either with direct nanohybrid resin composite (Neo Spectra ST HV A2, Dentsply) restorations or indirect restorations using computer-aided design/computer-aided manufacturing (CAD/CAM) method with hybrid ceramic material (Cerasmart 270 HT A2, GC). The direct (n =30) and indirect (n=30) restorations of postgraduate clinicians and direct restorations (n=30) of undergraduate clinicians (5th grade) were compared immediately (T1) and one month (T2) after the restorative procedures. A single dental technician performed the digital design and the milling of all indirect restorations. Static and dynamic occlusal contact surfaces of the teeth were quantitatively assessed through the collected digital scans by an intraoral scanner (iTero Element 5D, Align), using a computer software program (ChairsideCAD 3.1, Exocad, Align), by setting contact distances to 10, 50, 100, 150, 200, 250, 300, and 350 μm, gradually. The static contacts were assessed by calculating the percentage of the occlusal contact surfaces to the entire occlusal contact surface for each restored tooth, using the ImageJ software program (National Institutes of Health). The dynamic contacts were assessed according to the presence (positive) or absence (negative), regarding 4 lateral movements of the mandibular arch (0.5, 1, 2, and 3 mm on the working side) using a virtual articulator integrated to the ChairsideCAD.

Обзор исследования

Статус

Завершенный

Подробное описание

The study was conducted on patients who applied to the undergraduate and postgraduate clinics of the Department of Restorative Dentistry, Marmara University Dentistry Faculty. The number of teeth to be included in the study was determined by Statistical Power Analysis (G-Power Analysis). With 90% confidence (1-α), 85% test power (1-β), and an effect size of f =0.276, the total number of teeth to be included in the study for 3 groups was determined to be a minimum of 90. Patients aged between 17 and 45 requiring restoration of maxillary or mandibular first molar teeth were included in the study. The teeth with mesial-occlusal-distal (MOD) cavity preparation encompassing 50% of the intercuspal distance for direct restorations and overlay preparation for indirect restorations were included. The ones having asymptomatic root canal treatments were also included. Those who had caries, crowns, amalgam restorations, fractures, pathological wear, or severe periodontal problems on their maxillary or mandibular first molar teeth were excluded from the study. The patients who had active temporomandibular disorders, missing teeth, primary dentition, posterior disocclusion, posterior crossbite, and anterior openbite were also excluded. Those who were undergoing active orthodontic treatment were excluded from the study. Finally, total of 90 maxillary or mandibular first molars were selected from 45 patients. All the included patients were informed about the study procedures and provided written informed consent before the study.

The restorations were performed using standardized equipment and techniques for the study groups either by a 5th-grade undergraduate clinician or a postgraduate clinician with 5 years of clinical experience. Three application groups were determined according to the type of posterior restoration and clinician. The postgraduate clinician performed 30 direct posterior MOD restorations and 30 indirect overlay restorations, and the undergraduate clinician performed 30 direct posterior MOD restorations.

Intraoral scans of the final direct and indirect restorations were obtained at immediately after and one month recall periods using the Element 5D intraoral scanner. To prevent any unintended change in occlusion, the dental procedures were prohibited for the patients between the first and second intraoral scans. For each patient, full maxillary and mandibular arches and the interocclusal records were scanned and recorded by the postgraduate clinician, and the acquired scan data were exported as polygon file format (.PLY). Then 3D digital models of the jaws were transferred to a specific software program (ChairsideCAD 3.1, Exocad, Align), in which the static and dynamic occlusal contacts with the opposing dentition could be visualized. To evaluate static and dynamic occlusal contacts, two different methods were followed.

For static occlusal contacts, after importing .PLY files into ChairsideCAD software program, the tightness of the occlusal contact surfaces was visualized and evaluated by eight occlusal distance grades: 10, 50, 100, 150, 200, 250, 300, and 350 μm. High resolution .PNG images of upper or lower jaws' 3D models were generated from the occlusal plane when the entire occlusal surface and occlusal contact areas were visible. Therefore, 8 different 2D images representing each grade were recorded in high-resolution of 90 teeth immediately after the restorations and one month after the restorations.

For the dynamic occlusal contact surface evaluation, .PLY files were imported to ChairsideCAD 3.1 software program, then 3D models were mounted on a fully adjustable Arcon type virtual articulator (Artex CR, Amann Girrbach) integrated with the software. For the mounting of the maxillary arch model to the articulator, the mesio-incisal embrasure of the upper central teeth and the mesio-buccal tubercle of the left and right upper first molars were selected respectively. The virtual articulator was adjusted to the average value parameters: Bennett angle was set at 10 degrees, immediate side shift was set at 0.5 mm, condylar angle was set at 30 degrees, and incisal table angle was set at 30 degrees as described in a previous research. In the articulator tool of the software program, the lateral movements of 0.5, 1, 2, and 3 mm were set gradually to the working side. The tightness of the occlusal contact surfaces was defined by the same occlusal distances as in static occlusal contacts (10, 50, 100, 150, 200, 250, 300, and 350 µm). The occlusal surface dynamic contacts were assessed as positive (+) or negative (-) for each lateral movement step, for all occlusal distances, immediately after the restorations and one month after the restorations.

Тип исследования

Наблюдательный

Регистрация (Действительный)

45

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

От 17 лет до 45 лет (Ребенок, Взрослый)

Принимает здоровых добровольцев

Да

Полы, имеющие право на обучение

Все

Метод выборки

Невероятностная выборка

Исследуемая популяция

Patients aged between 17 and 45 requiring restoration of maxillary or mandibular first molar teeth were included in the study. The teeth with mesial-occlusal-distal (MOD) cavity preparation encompassing 50% of the intercuspal distance for direct restorations and overlay preparation for indirect restorations were included. The ones having asymptomatic root canal treatments were also included. Those who had caries, crowns, amalgam restorations, fractures, pathological wear, or severe periodontal problems on their maxillary or mandibular first molar teeth were excluded from the study. The patients who had active temporomandibular disorders, missing teeth, primary dentition, posterior disocclusion, posterior crossbite, and anterior openbite were also excluded. Those who were undergoing active orthodontic treatment were excluded from the study. Finally, total of 90 maxillary or mandibular first molars were selected from 45 patients. All the included patients were informed about the study.

Описание

Inclusion Criteria:

  • Sufficient cognitive ability to understand the consent process
  • 17-45 years old
  • Clinically healthy gingiva and periodontal tissues

Exclusion Criteria:

  • Missing teeth except third molars
  • Ongoing orthodontic or prosthetic treatments that may affect occlusion
  • Bruxism

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Наблюдательные модели: CASE_CONTROL
  • Временные перспективы: RETROSPECTIVE

Когорты и вмешательства

Группа / когорта
Postgraduate indirect restoration group

All indirect restorations were single visit, overlay cad/cam restorations using hybrid ceramic blocks (Cerasmart 270 HT A2, GC). Selected maxillary and mandibular vital teeth or teeth with root canal treatment were restored. Non-retentive overlay preparations were performed by the clinicians. Marginal elevation was performed when necessary, using a highly filled flowable composite (Gaenial Universal Injectable A2 shade, GC) and partial precontoured matrix bands (Tor VM). No periodontal surgery, gingival retraction method, or rubber dam isolation was used before the restorations. The immediate dentin sealing procedure was performed for the vital teeth.

Postgraduate direct restoration group

The direct posterior MOD restorations on maxillary and mandibular vital teeth or teeth with root canal treatment were performed by the postgraduate clinicians using a nanoceramic resin composite (Neo Spectra ST HV A2, Dentsply). MOD cavities were prepared without bevels. Following the successful adaptation of precontoured matrix bands (0.050 mm thickness, Tor VM) and wooden wedges to the mesial and distal margins of the cavities, selective enamel etching was applied. Then a universal adhesive agent (G-Premio Bond, GC) was applied according to the manufacturer's instructions. The composite was layered incrementally by starting to shape both marginal walls and then the rest was performed using the cusp-to-cusp technique. Each layer was cured by a calibrated LED curing unit (Elipar Deepcure S, 3M ESPE) for 10 seconds.

Undergraduate direct restoration group

The direct posterior MOD restorations on maxillary and mandibular vital teeth or teeth with root canal treatment were performed by the undergraduate clinicians using a nanoceramic resin composite (Neo Spectra ST HV A2, Dentsply) with the same clinical protocol. MOD cavities were prepared without bevels. Following the successful adaptation of precontoured matrix bands (0.050 mm thickness, Tor VM) and wooden wedges to the mesial and distal margins of the cavities, selective enamel etching was applied. Then a universal adhesive agent (G-Premio Bond, GC) was applied according to the manufacturer's instructions. The composite was layered incrementally by starting to shape both marginal walls and then the rest was performed using the cusp-to-cusp technique. Each layer was cured by a calibrated LED curing unit (Elipar Deepcure S, 3M ESPE) for 10 seconds.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Assessment of the level of static occlusal area percentage and dynamic occlusal contact presence of direct and indirect restorations, using ChairsideCAD and imageJ softwares.
Временное ограничение: Immediately after and 1 month follow-up

Measurements of the level of static and dynamic occlusal contacts for differences of direct and indirect restoration types. Static occlusal contact areas were calculated as ratio of tooth contact area to total occlusal area. Dynamic occlusal contacts were calculated as presence.

Immediately after and 1 month follow-up

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Assessment of the clinical experience factor regarding the occlusal contact levels for direct restorations for both static occlusal contact area and dynamic occlusal contact presence, using ChairsideCAD and imageJ softwares.
Временное ограничение: Immediately after and 1 month follow-up

Measurement of clinical experience factor regarding the occlusal contact level differences of direct postgraduate and direct undergraduate restorations. Static occlusal contact areas were calculated as ratio of tooth contact area to total occlusal area. Dynamic occlusal contacts were calculated as presence.

Immediately after and 1 month follow-up

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

3 июня 2024 г.

Первичное завершение (Действительный)

13 января 2025 г.

Завершение исследования (Действительный)

6 июня 2025 г.

Даты регистрации исследования

Первый отправленный

30 сентября 2026 г.

Впервые представлено, что соответствует критериям контроля качества

30 сентября 2026 г.

Первый опубликованный (Действительный)

6 октября 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

13 октября 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

7 октября 2026 г.

Последняя проверка

1 сентября 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • 09.2024.727

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

ДА

Описание плана IPD

All data obtained without working will be shared if requested.

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться