Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Diagnostic Accuracy of Innovative Photo-Analysis Software in Resin Composite Shade Matching

15 juli 2026 uppdaterad av: Ahmed Mohamed Saleh Ali Farrag, Misr University for Science and Technology

In Vivo Diagnostic Accuracy of Innovative Photo-Analysis Software and Digital Spectrophotometer Compared With Visual Technique in Resin Composite Shade Matching

This study aims to assess the agreement between new computer software using dental photographs, digital spectrophotometer and the visual technique, in achieving accurate resin composite shade matching.

Studieöversikt

Status

Rekrytering

Betingelser

Intervention / Behandling

Detaljerad beskrivning

  • Custom composite resin shade tabs are fabricated and catalogued to serve as reference standards during shade matching.
  • Teeth are professionally cleaned on dental chair using a nylon prophylaxis brush with polishing paste to ensure complete removal of extrinsic stains and to reveal the native tooth color.
  • Participants will be seated on an adjustable chair in an upright posture, with the head oriented perpendicular to the floor and be stabilized by a headrest. The chair will be positioned against a matte white wall adjacent to a clear window to standardize a neutral background and exploit consistent daylight illumination.
  • Patients will be instructed to maintain an upright head posture with the interpupillary line parallel to the floor. All measurements will be performed under daylight, while extraneous light sources and environmental interferences to be minimized.

    • Computer-Assisted Software A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth.

The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized.

The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third of the labial crown of either the tooth or shade tabs.

Candidate shades are then quantitatively compared to the region of interest by computing CIEDE2000 color-difference values (ΔE₀₀), which incorporate corrections for lightness, chroma, and hue; the final selected shade is the one yielding the smallest ΔE₀₀.

Where: ΔL', ΔC', ΔH' are the lightness, chroma, and hue differences in the CIEDE2000 framework; SL, SC, SH are weighting functions; kL, kC, kH are parametric factors (set to 1 unless otherwise justified); and RT is the rotation term accounting for interaction between chroma and hue differences.

  • Spectrophotometer assessment A pre-calibrated spectrophotometer (per manufacturer guidelines) independently measures tooth and shade-tab color. Measurements are reported as CIE L*, a*, b* values. For each tooth-tab combination, the CIEDE2000 color difference (ΔE00) is calculated; the tab yielding the minimal ΔE00 is accepted as the selected shade. 9
  • Visual Shade Matching Under the same conditions (lighting and patient positioning), experienced assessors independently determine the matching shade.

Agreement between their own assessments and between the other assessors' assessments, as well as the extent of their discrepancies, is quantified using kappa test.

Studietyp

Interventionell

Inskrivning (Beräknad)

52

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

  • Namn: Esraa Esmeail Hussien EEH lecturer, phd holder
  • Telefonnummer: +201111103836
  • E-post: dr.esraaism@gmail.com

Studera Kontakt Backup

  • Namn: Ahmed Saleh Ali ASA Resident doctor, Bachelor degree
  • Telefonnummer: +201147965014
  • E-post: ahmed.msaleh@must.edu.eg

Studieorter

    • Giza Governorate
      • Sixth of October, Giza Governorate, Egypten, 12566
        • Rekrytering
        • Misr University for Science and Technology

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen

Tar emot friska volontärer

Nej

Beskrivning

Inclusion Criteria:

  • Age: 18-45 years.
  • Sex: Male or female.
  • General: Cooperative individuals who agree to participate and comply with study visits (written informed consent to be obtained as applicable).
  • Dentition: Presence of sound maxillary incisors that will meet the tooth-level criteria.

Exclusion Criteria:

  • Poor oral hygiene.
  • Severe systemic/medical complications that may contraindicate elective dental care.
  • Pregnancy.
  • Heavy smokers.
  • Xerostomia.
  • Temporomandibular joint disorders.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Diagnostisk
  • Tilldelning: Randomiserad
  • Interventionsmodell: Crossover tilldelning
  • Maskning: Dubbel

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Aktiv komparator: Digital Spectrophotometer
A pre-calibrated spectrophotometer (per manufacturer guidelines) independently measures tooth and shade-tab color. Measurements are reported as CIE L*, a*, b* values. For each tooth-tab combination, the CIEDE2000 color difference (ΔE00) is calculated; the tab yielding the minimal ΔE00 is accepted as the selected shade.

A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth.

The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized.

The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third.

Aktiv komparator: Visual Shade Matching
Under the same conditions (lighting and patient positioning), experienced assessors independently determine the matching shade.

A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth.

The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized.

The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Accuracy of computer software, digital Spectrophotometer and visual method in shade matching using resin composite tabs.
Tidsram: Baseline
• The outcome evaluates agreement of the computer software in comparison to spectrophotometer and traditional visual method.
Baseline

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

1 maj 2026

Primärt slutförande (Beräknad)

1 september 2026

Avslutad studie (Beräknad)

1 oktober 2026

Studieregistreringsdatum

Först inskickad

10 juli 2026

Först inskickad som uppfyllde QC-kriterierna

15 juli 2026

Första postat (Faktisk)

16 juli 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

16 juli 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

15 juli 2026

Senast verifierad

1 juli 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

JA

IPD-planbeskrivning

will be shared with supervisors

IPD-delning som stöder informationstyp

  • STUDY_PROTOCOL
  • SAV
  • ICF
  • ANALYTIC_CODE
  • CSR

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera