- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07707323
Diagnostic Accuracy of Innovative Photo-Analysis Software in Resin Composite Shade Matching
In Vivo Diagnostic Accuracy of Innovative Photo-Analysis Software and Digital Spectrophotometer Compared With Visual Technique in Resin Composite Shade Matching
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
- Custom composite resin shade tabs are fabricated and catalogued to serve as reference standards during shade matching.
- Teeth are professionally cleaned on dental chair using a nylon prophylaxis brush with polishing paste to ensure complete removal of extrinsic stains and to reveal the native tooth color.
- Participants will be seated on an adjustable chair in an upright posture, with the head oriented perpendicular to the floor and be stabilized by a headrest. The chair will be positioned against a matte white wall adjacent to a clear window to standardize a neutral background and exploit consistent daylight illumination.
Patients will be instructed to maintain an upright head posture with the interpupillary line parallel to the floor. All measurements will be performed under daylight, while extraneous light sources and environmental interferences to be minimized.
- Computer-Assisted Software A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth.
The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized.
The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third of the labial crown of either the tooth or shade tabs.
Candidate shades are then quantitatively compared to the region of interest by computing CIEDE2000 color-difference values (ΔE₀₀), which incorporate corrections for lightness, chroma, and hue; the final selected shade is the one yielding the smallest ΔE₀₀.
Where: ΔL', ΔC', ΔH' are the lightness, chroma, and hue differences in the CIEDE2000 framework; SL, SC, SH are weighting functions; kL, kC, kH are parametric factors (set to 1 unless otherwise justified); and RT is the rotation term accounting for interaction between chroma and hue differences.
- Spectrophotometer assessment A pre-calibrated spectrophotometer (per manufacturer guidelines) independently measures tooth and shade-tab color. Measurements are reported as CIE L*, a*, b* values. For each tooth-tab combination, the CIEDE2000 color difference (ΔE00) is calculated; the tab yielding the minimal ΔE00 is accepted as the selected shade. 9
- Visual Shade Matching Under the same conditions (lighting and patient positioning), experienced assessors independently determine the matching shade.
Agreement between their own assessments and between the other assessors' assessments, as well as the extent of their discrepancies, is quantified using kappa test.
Typ studiów
Zapisy (Szacowany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: Esraa Esmeail Hussien EEH lecturer, phd holder
- Numer telefonu: +201111103836
- E-mail: dr.esraaism@gmail.com
Kopia zapasowa kontaktu do badania
- Nazwa: Ahmed Saleh Ali ASA Resident doctor, Bachelor degree
- Numer telefonu: +201147965014
- E-mail: ahmed.msaleh@must.edu.eg
Lokalizacje studiów
-
-
Giza Governorate
-
Sixth of October, Giza Governorate, Egipt, 12566
- Rekrutacyjny
- Misr University for Science and Technology
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Age: 18-45 years.
- Sex: Male or female.
- General: Cooperative individuals who agree to participate and comply with study visits (written informed consent to be obtained as applicable).
- Dentition: Presence of sound maxillary incisors that will meet the tooth-level criteria.
Exclusion Criteria:
- Poor oral hygiene.
- Severe systemic/medical complications that may contraindicate elective dental care.
- Pregnancy.
- Heavy smokers.
- Xerostomia.
- Temporomandibular joint disorders.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Diagnostyczny
- Przydział: Randomizowane
- Model interwencyjny: Zadanie krzyżowe
- Maskowanie: Podwójnie
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: Digital Spectrophotometer
A pre-calibrated spectrophotometer (per manufacturer guidelines) independently measures tooth and shade-tab color.
Measurements are reported as CIE L*, a*, b* values.
For each tooth-tab combination, the CIEDE2000 color difference (ΔE00) is calculated; the tab yielding the minimal ΔE00 is accepted as the selected shade.
|
A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth. The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized. The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third. |
|
Aktywny komparator: Visual Shade Matching
Under the same conditions (lighting and patient positioning), experienced assessors independently determine the matching shade.
|
A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth. The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized. The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third. |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Accuracy of computer software, digital Spectrophotometer and visual method in shade matching using resin composite tabs.
Ramy czasowe: Baseline
|
• The outcome evaluates agreement of the computer software in comparison to spectrophotometer and traditional visual method.
|
Baseline
|
Współpracownicy i badacze
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Inne numery identyfikacyjne badania
- 2026/0037
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Opis planu IPD
Typ informacji pomocniczych dotyczących udostępniania IPD
- PROTOKÓŁ BADANIA
- SOK ROŚLINNY
- ICF
- ANALITYCZNY_KOD
- CSR
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .