- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT07707323
Diagnostic Accuracy of Innovative Photo-Analysis Software in Resin Composite Shade Matching
In Vivo Diagnostic Accuracy of Innovative Photo-Analysis Software and Digital Spectrophotometer Compared With Visual Technique in Resin Composite Shade Matching
Обзор исследования
Статус
Условия
Вмешательство/лечение
Подробное описание
- Custom composite resin shade tabs are fabricated and catalogued to serve as reference standards during shade matching.
- Teeth are professionally cleaned on dental chair using a nylon prophylaxis brush with polishing paste to ensure complete removal of extrinsic stains and to reveal the native tooth color.
- Participants will be seated on an adjustable chair in an upright posture, with the head oriented perpendicular to the floor and be stabilized by a headrest. The chair will be positioned against a matte white wall adjacent to a clear window to standardize a neutral background and exploit consistent daylight illumination.
Patients will be instructed to maintain an upright head posture with the interpupillary line parallel to the floor. All measurements will be performed under daylight, while extraneous light sources and environmental interferences to be minimized.
- Computer-Assisted Software A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth.
The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized.
The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third of the labial crown of either the tooth or shade tabs.
Candidate shades are then quantitatively compared to the region of interest by computing CIEDE2000 color-difference values (ΔE₀₀), which incorporate corrections for lightness, chroma, and hue; the final selected shade is the one yielding the smallest ΔE₀₀.
Where: ΔL', ΔC', ΔH' are the lightness, chroma, and hue differences in the CIEDE2000 framework; SL, SC, SH are weighting functions; kL, kC, kH are parametric factors (set to 1 unless otherwise justified); and RT is the rotation term accounting for interaction between chroma and hue differences.
- Spectrophotometer assessment A pre-calibrated spectrophotometer (per manufacturer guidelines) independently measures tooth and shade-tab color. Measurements are reported as CIE L*, a*, b* values. For each tooth-tab combination, the CIEDE2000 color difference (ΔE00) is calculated; the tab yielding the minimal ΔE00 is accepted as the selected shade. 9
- Visual Shade Matching Under the same conditions (lighting and patient positioning), experienced assessors independently determine the matching shade.
Agreement between their own assessments and between the other assessors' assessments, as well as the extent of their discrepancies, is quantified using kappa test.
Тип исследования
Регистрация (Оцененный)
Фаза
- Непригодный
Контакты и местонахождение
Контакты исследования
- Имя: Esraa Esmeail Hussien EEH lecturer, phd holder
- Номер телефона: +201111103836
- Электронная почта: dr.esraaism@gmail.com
Учебное резервное копирование контактов
- Имя: Ahmed Saleh Ali ASA Resident doctor, Bachelor degree
- Номер телефона: +201147965014
- Электронная почта: ahmed.msaleh@must.edu.eg
Места учебы
-
-
Giza Governorate
-
Sixth of October, Giza Governorate, Египет, 12566
- Рекрутинг
- Misr University for Science and Technology
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
- Взрослый
Принимает здоровых добровольцев
Описание
Inclusion Criteria:
- Age: 18-45 years.
- Sex: Male or female.
- General: Cooperative individuals who agree to participate and comply with study visits (written informed consent to be obtained as applicable).
- Dentition: Presence of sound maxillary incisors that will meet the tooth-level criteria.
Exclusion Criteria:
- Poor oral hygiene.
- Severe systemic/medical complications that may contraindicate elective dental care.
- Pregnancy.
- Heavy smokers.
- Xerostomia.
- Temporomandibular joint disorders.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Диагностика
- Распределение: Рандомизированный
- Интервенционная модель: Назначение кроссовера
- Маскировка: Двойной
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Активный компаратор: Digital Spectrophotometer
A pre-calibrated spectrophotometer (per manufacturer guidelines) independently measures tooth and shade-tab color.
Measurements are reported as CIE L*, a*, b* values.
For each tooth-tab combination, the CIEDE2000 color difference (ΔE00) is calculated; the tab yielding the minimal ΔE00 is accepted as the selected shade.
|
A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth. The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized. The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third. |
|
Активный компаратор: Visual Shade Matching
Under the same conditions (lighting and patient positioning), experienced assessors independently determine the matching shade.
|
A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth. The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized. The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third. |
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Accuracy of computer software, digital Spectrophotometer and visual method in shade matching using resin composite tabs.
Временное ограничение: Baseline
|
• The outcome evaluates agreement of the computer software in comparison to spectrophotometer and traditional visual method.
|
Baseline
|
Соавторы и исследователи
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Оцененный)
Завершение исследования (Оцененный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Другие идентификационные номера исследования
- 2026/0037
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Описание плана IPD
Совместное использование IPD Поддерживающий тип информации
- STUDY_PROTOCOL
- САП
- МКФ
- АНАЛИТИЧЕСКИЙ_КОД
- КСО
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .