Choroidal Thickness During Changes in Intraocular Pressure and Arterial Blood Pressure
Age-related macular degeneration (AMD) and glaucoma are among the leading causes of blindness in the western world. Elevated intraocular pressure (IOP) is a well known major risk factor for glaucoma. In addition, there is growing evidence that vascular factors, including arterial hypertension and hypotension, may play a role in the pathogenesis of AMD and glaucoma. To gain more insight into these mechanisms in humans is the primary goal of the present study.
Optical coherence tomography (OCT) delivers three dimensional, volumetric reflectivity information through transparent media in vivo. Moreover, the images show a high choroidal penetration and a resolution comparable to an histologic examination when infrared light sources are used. Because of its non-invasive character, OCT provides an ideal method for diagnosis and monitoring of retinal and choroidal abnormalities.
The present study aims to investigate whether choroidal thickness is temporarily altered by changes in IOP or systemic hemodynamic parameters. IOP will be increased by the use of a suction cup technique, mean arterial blood pressure will be altered by intravenously administered Phenylephrine or Sodium-Nitroprusside.
研究概览
地位
条件
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Vienna、奥地利、1090
- Department of Clinical Pharmacology, Medical University of Vienna
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Men and women aged between 18 and 35 years, nonsmokers
- Men and women will be included in equal parts
- Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant
- Normal findings in the laboratory testings unless the investigator considers an abnormality to be clinically irrelevant
- Normal ophthalmic findings, ametropia less than 1 diopter
Exclusion Criteria:
- Regular use of medication, abuse of alcoholic beverages, participation in a clinical trial in the 3 weeks preceding the study
- Treatment in the previous 3 weeks with any drug (except oral contraceptives)
- Symptoms of a clinically relevant illness in the 3 weeks before the first study day
- Blood donation during the previous 3 weeks History of hypersensitivity to the trial drugs or to drugs with a similar chemical structure
- History or presence of gastrointestinal, liver or kidney disease, or other conditions known to interfere with distribution, metabolism or excretion of study drugs
- History of migraine
- Pregnancy
学习计划
研究是如何设计的?
设计细节
- 主要用途:基础科学
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:三倍
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:Sodium-Nitroprusside
Nipruss®, Sanol-Schwarz, Monheim, Germany 0, 0.5, 1 and 2 µg/kg/min, each infusion step for 5 minutes, total infusion period of 20 minutes
|
Neosynephrine®, Winthrop Breon Laboratories New York, NY, USA 0, 0.5, 1 and 2 μg/kg/min, each infusion step for 5 minutes, total infusion period of 20 minutes
Nipruss®, Sanol-Schwarz, Monheim, Germany 0, 0.5, 1 and 2 µg/kg/min, each infusion step for 5 minutes, total infusion period of 20 minutes
experimental stepwise increase of intraocular pressure while measurement of choroidal thickness suction force of 25, 50, 75, and 100 mmH
眼压测量
Optical coherence tomography is a widely used non-invasive method to image the retina and choroid.
Using a 1060nm light source coupled to a commercially available OCT system (Heidelberg Engineering, Heidelberg, Germany) allows for the measurement of choroidal thickness
|
|
有源比较器:Phenylephrine
Neosynephrine®, Winthrop Breon Laboratories New York, NY, USA 0, 0.5, 1 and 2 μg/kg/min, each infusion step for 5 minutes, total infusion period of 20 minutes
|
Neosynephrine®, Winthrop Breon Laboratories New York, NY, USA 0, 0.5, 1 and 2 μg/kg/min, each infusion step for 5 minutes, total infusion period of 20 minutes
Nipruss®, Sanol-Schwarz, Monheim, Germany 0, 0.5, 1 and 2 µg/kg/min, each infusion step for 5 minutes, total infusion period of 20 minutes
experimental stepwise increase of intraocular pressure while measurement of choroidal thickness suction force of 25, 50, 75, and 100 mmH
眼压测量
Optical coherence tomography is a widely used non-invasive method to image the retina and choroid.
Using a 1060nm light source coupled to a commercially available OCT system (Heidelberg Engineering, Heidelberg, Germany) allows for the measurement of choroidal thickness
|
|
有源比较器:Suction Cup
suction force of 25, 50, 75, and 100 mmHg
|
Neosynephrine®, Winthrop Breon Laboratories New York, NY, USA 0, 0.5, 1 and 2 μg/kg/min, each infusion step for 5 minutes, total infusion period of 20 minutes
Nipruss®, Sanol-Schwarz, Monheim, Germany 0, 0.5, 1 and 2 µg/kg/min, each infusion step for 5 minutes, total infusion period of 20 minutes
experimental stepwise increase of intraocular pressure while measurement of choroidal thickness suction force of 25, 50, 75, and 100 mmH
眼压测量
Optical coherence tomography is a widely used non-invasive method to image the retina and choroid.
Using a 1060nm light source coupled to a commercially available OCT system (Heidelberg Engineering, Heidelberg, Germany) allows for the measurement of choroidal thickness
|
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
Choroidal thickness
大体时间:18 months
|
18 months
|
次要结果测量
结果测量 |
大体时间 |
|---|---|
|
Systolic/diastolic blood pressure (non-invasive)
大体时间:18 months
|
18 months
|
|
Intraocular pressure (IOP)
大体时间:18 months
|
18 months
|
合作者和调查者
调查人员
- 首席研究员:Gerhard Garhöfer, MD, PD、Department of Clinical Pharmacology, Medical University of Vienna
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.