Closed-Loop Fluid Administration System Using Hemodynamic Monitors
2016年4月20日 更新者:Maxime Cannesson、University of California, Irvine
The purpose of this study is to evaluate the feasibility of a closed-loop (automated) fluid administration system to deliver fluids using feedback from standard operating room hemodynamic monitors.
In standard anesthesia care the rate of IV fluid administration to the patient is determined by the anesthesiologist caring for the patient.
In this study protocol, the rate of fluid administration will be determined instead by the closed-loop (automated) control system under the supervision of the anesthesiologist.
The system will independently decide when to give fluid and at what rate; the supervising anesthesiologist will monitor the system to ensure appropriate volumes are being delivered and to intervene if necessary.
研究概览
详细说明
In our protocol we will test the hypothesis that closed-loop fluid administration can maintain higher cardiac stroke volume (shown to improve patient outcomes after surgery) than anesthesiologist management.
We have shown this to be the case in multiple simulation studies and in-vivo animal studies, but not yet experimentally in a clinical setting.
Investigators will recruit their patients from the surgical record that that require cardiac output monitoring undergoing surgery and require mechanical ventilation and consent to participate in the study will be included in the study.
They will receive standard patient care in that in no way will their anesthetic or surgical procedure will be altered as part of the study, with the exception of fluid administration.
Fluids are usually given to a patient based on the physician's discretion.
As part of the study patients will receive fluid management via a closed loop (automated) system that will use an infusion pump (Q-Core) and a controller (a computer run index and algorithm developed by Sironis) to make frequent, regular and accurate adjustments to the amount of fluid the patient receives using feedback from standard operating room monitors at UCI).
Data from this study will be retrospectively compared to subjects case matched to evaluate differences in cardiac output, total fluid given, and patient outcomes.
研究类型
介入性
注册 (实际的)
40
阶段
- 不适用
联系人和位置
本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。
学习地点
-
-
California
-
Orange、California、美国、92858
- University of California, Irvine Medical Center
-
-
参与标准
研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。
资格标准
适合学习的年龄
18年 及以上 (成人、年长者)
接受健康志愿者
不
有资格学习的性别
全部
描述
Inclusion Criteria:
- Adult subjects (over the age of 18)
- Subjects undergoing elective major, abdominal surgery
- Subjects requiring general anesthesia and mechanical ventilation
- Subjects requiring cardiac output monitoring and an arterial line
Exclusion Criteria:
- Subjects under 18 years of age
- Subjects not undergoing surgery
- Subjects not requiring general anesthesia or mechanical ventilation
- Subjects not requiring cardiac output monitoring or an arterial line
- Subjects who are pregnant
- Subjects without the capacity to give informed consent
学习计划
本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Closed Loop
Study patients will receive a baseline crystalloid infusion of 3 cc/kg/hr and all additional fluid management will be performed via a closed loop (automated) system that will determine rate, amount, and timing of fluid administration.
|
Fluid management in the closed loop group will be performed via a closed loop (automated) system that will use an infusion pump (Q-Core) and a controller (a computer run index and algorithm developed by Sironis) to make frequent, regular and accurate adjustments to the amount of fluid the patient receives using feedback from standard operating room monitors.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Fluid Status During Surgery
大体时间:Duration of Surgery, up to 8 hours
|
The primary outcome between groups is preload independence, defined as % case time where Stroke Volume Variation (SVV) is ≤12%.
|
Duration of Surgery, up to 8 hours
|
合作者和调查者
在这里您可以找到参与这项研究的人员和组织。
调查人员
- 首席研究员:Maxime Cannesson, MD, PhD、University of California, Irvine
出版物和有用的链接
负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。
一般刊物
- Pearse R, Dawson D, Fawcett J, Rhodes A, Grounds RM, Bennett ED. Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care. 2005;9(6):R687-93. doi: 10.1186/cc3887. Epub 2005 Nov 8.
- Rinehart J, Liu N, Alexander B, Cannesson M. Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization? Anesth Analg. 2012 Jan;114(1):130-43. doi: 10.1213/ANE.0b013e318230e9e0. Epub 2011 Sep 29.
- Bednarski P, Siclari F, Voigt A, Demertzis S, Lau G. Use of a computerized closed-loop sodium nitroprusside titration system for antihypertensive treatment after open heart surgery. Crit Care Med. 1990 Oct;18(10):1061-5. doi: 10.1097/00003246-199010000-00002.
- Colvin JR, Kenny GN. Development and evaluation of a dual-pump microcomputer-based closed-loop arterial pressure control system. Int J Clin Monit Comput. 1989 Jan;6(1):31-5. doi: 10.1007/BF01723370.
- Blankenship HB, Wallace FD, Pacifico AD. Clinical application of closed-loop postoperative autotransfusion. Med Prog Technol. 1990 May;16(1-2):89-93.
- Bowman RJ, Westenskow DR. A microcomputer-based fluid infusion system for the resuscitation of burn patients. IEEE Trans Biomed Eng. 1981 Jun;28(6):475-9. doi: 10.1109/TBME.1981.324822. No abstract available.
- Chaisson NF, Kirschner RA, Deyo DJ, Lopez JA, Prough DS, Kramer GC. Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage. J Trauma. 2003 May;54(5 Suppl):S183-92. doi: 10.1097/01.TA.0000064508.11512.28.
- DeBey RK, Westenskow DR, Jordan WS, McJames SW. A urine based control system for fluid infusion. Biomed Sci Instrum. 1987;23:195-8. No abstract available.
- Rinehart J, Alexander B, Le Manach Y, Hofer C, Tavernier B, Kain ZN, Cannesson M. Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: an in silico simulation study. Crit Care. 2011;15(6):R278. doi: 10.1186/cc10562. Epub 2011 Nov 23.
- Rinehart J, Lee C, Cannesson M, Dumont G. Closed-loop fluid resuscitation: robustness against weight and cardiac contractility variations. Anesth Analg. 2013 Nov;117(5):1110-8. doi: 10.1213/ANE.0b013e3182930050.
- Rinehart J, Lee C, Canales C, Kong A, Kain Z, Cannesson M. Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study. Anesth Analg. 2013 Nov;117(5):1119-29. doi: 10.1213/ANE.0b013e3182937d61.
- Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010 Oct;111(4):910-4. doi: 10.1213/ANE.0b013e3181eb624f. Epub 2010 Aug 12.
- Rinehart J, Chung E, Canales C, Cannesson M. Intraoperative stroke volume optimization using stroke volume, arterial pressure, and heart rate: closed-loop (learning intravenous resuscitator) versus anesthesiologists. J Cardiothorac Vasc Anesth. 2012 Oct;26(5):933-9. doi: 10.1053/j.jvca.2012.05.015. Epub 2012 Jul 12.
- Rinehart J, Lilot M, Lee C, Joosten A, Huynh T, Canales C, Imagawa D, Demirjian A, Cannesson M. Closed-loop assisted versus manual goal-directed fluid therapy during high-risk abdominal surgery: a case-control study with propensity matching. Crit Care. 2015 Mar 19;19(1):94. doi: 10.1186/s13054-015-0827-7.
- Joosten A, Huynh T, Suehiro K, Canales C, Cannesson M, Rinehart J. Goal-Directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: A pilot study. Br J Anaesth. 2015 Jun;114(6):886-92. doi: 10.1093/bja/aev002. Epub 2015 Feb 17.
有用的网址
研究记录日期
这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。
研究主要日期
学习开始
2012年11月1日
初级完成 (实际的)
2014年5月1日
研究完成 (实际的)
2014年5月1日
研究注册日期
首次提交
2013年12月19日
首先提交符合 QC 标准的
2013年12月19日
首次发布 (估计)
2013年12月25日
研究记录更新
最后更新发布 (估计)
2016年5月27日
上次提交的符合 QC 标准的更新
2016年4月20日
最后验证
2016年4月1日
更多信息