A Pilot Study for the Evaluation of the Safety and Performance of a Combined OCT System (Hydra01)
A Prospective,Open Label,Non-randomized,Single-centre,Exploratory,Stratified Pilot Study for the Evaluation of the Safety and Performance of a Combined Coaxial Optical Coherence Tomography (OCT) System,to Image Diseases of the Posterior and Anterior Segment of the Eye
The novel Coaxial Optical Coherence Tomography (OCT) System is designed to visualize both structures of the retina and choroid.
The purpose of this research is the safety and evaluation of a combined coaxial optical coherence tomography (OCT) system, to image diseases of the posterior and anterior segment of the eye.
研究概览
详细说明
Background and Rationale:
Many posterior segment ocular diseases involve the retinal and choroidal vasculature. A new technology to noninvasively and simultaneously visualize vascular pathology is of utmost importance to reduce patient exposure to different diagnosis methods like e.g. fluorescence angiography. The novel Coaxial Optical Coherence Tomography (OCT) System is designed to visualize both structures of the retina and choroid.
Furthermore, it may be used to image other structures of the eye.
Objective(s):
The purpose of this research is the safety and evaluation of a combined coaxial optical coherence tomography (OCT) system, to image diseases of the posterior and anterior segment of the eye. This device may be useful for the early diagnosis and monitoring of a variety of diseases involving the eye, such as Glaucoma, Diabetic Retinopathy or Age-Related Macular Degeneration. Measurements are compared to normal controls.
Measurements and procedures:
After screening, all participants will undergo a scanning procedure on the same day.
Only one eye of each participant will be scanned with the investigational device. For patients, the eye showing the disease will be chosen, for healthy volunteers, the left or right eye will be scanned according to a randomisation list.
The image quality is rated by the investigator and an independent assessor on a VAS (visual analogue scale). A subgroup of each stratum will have a comparative measurement of the choroid thickness against a SS-OCT (swept-source-OCT) device (Topcon) and a retina thickness against the Spectralis data. The subgroup will consist of half planned sample size. The measurement is taken from one eye, ie. every second participant per stratum will be attributed to the thickness measurement subgroup. The endpoint is a true/false criterion on whether the measurement of the retina and choroid thickness was successful. The thickness is measured in μm. The measurement is considered a "success" if the value is no more than +/- 10% off the reference measurement.
研究类型
注册 (实际的)
阶段
- 不适用
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Subjects with healthy eye, or has been diagnosed already with eye disease
- Patients > 18 years of age
- Informed Consent as documented by date and signature
Exclusion Criteria:
- Clinically significant concomitant disease that impair measurement
- Inability to follow the procedures of the study, e.g. due to language problems, psychological disorders, late stage Alzheimer disease, etc. of the participant,
- Subjects using implanted electronic medical devices (e.g. cochlear implant, pacemaker, defibrillator, infusion pump).
- Participation in another study with investigational drug within the 30 days preceding and during the present study
学习计划
研究是如何设计的?
设计细节
- 主要用途:诊断
- 分配:非随机化
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
其他:Healthy subjects
One eye of each participant will be scanned with the investigational device (= combined Coaxial Optical Coherence Tomography (OCT) System)
|
The investigational device is an OCT scanner prototype with two different wavelengths developed based on a CE marked OCT device (Spectralis® Heidelberg) at the Berner Fachhochschule, Biel
|
|
其他:Diseased groups
lf one eye is affected, this will be chosen.
lf both eyes are be affected, the eye with the severest symptoms will be chosen.
Scanning with the investigational device (= combined Coaxial Optical Coherence Tomography (OCT) System)
|
The investigational device is an OCT scanner prototype with two different wavelengths developed based on a CE marked OCT device (Spectralis® Heidelberg) at the Berner Fachhochschule, Biel
|
|
其他:Diseased subgroups
Every second subject will be allocated to the subgroup.
|
The investigational device is an OCT scanner prototype with two different wavelengths developed based on a CE marked OCT device (Spectralis® Heidelberg) at the Berner Fachhochschule, Biel
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Visual acuity (VA) after investigation
大体时间:Within 1 hour after investigation
|
Safety of the imaging investigation expressed as visual acuity before (baseline) and after imaging, and tolerability assessment questionnaire.
|
Within 1 hour after investigation
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Scan quality
大体时间:After completion of all measurement, an average of 2 years.
|
Comparing scan quality of investigational device to scan quality of a reference device, expressed as thickness of the retina and the thickness of the choroid
|
After completion of all measurement, an average of 2 years.
|
|
Procedural success
大体时间:After completion of all measurement, an average of 2 years.
|
Procedural success that is defined as: Image Quality of anterior and posterior eye structures
|
After completion of all measurement, an average of 2 years.
|
|
Procedural safety and comfort assessed by questionnaire
大体时间:Within 1 hour after investigation
|
Procedural comfort in the opinion of the patients assessed with a questionnaire
|
Within 1 hour after investigation
|
合作者和调查者
调查人员
- 研究主任:Hendrik PN Scholl, MD、University Hospital Basel, Dept. of Ophthalmology
- 首席研究员:Pascal Hasler, MD、University Hospital Basel, Dept. of Ophthalmology
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.