Hemodynamic Assessment in Acute Decompensated Heart Failure
Hemodynamic Assessment Throughout Diuretic Treatment in Acute Decompensated Heart Failure
研究概览
详细说明
This study will assess the ability of a novel optical measurement system to determine changes in the hemodynamic status of heart failure patients admitted to the hospital with a primary diagnosis of acute decompensated heart failure. Patients will be measured with both the novel measurement system and reference devices that are FDA-cleared for hemodynamic measurements. The measurements from the novel system will be compared to reference variables describing hemodynamic and congestive status, including stroke volume, central venous pressure, and serum levels of NT-proBNP.
All patients enrolled in the study will first provide written informed consent to participate and then the research coordinator will check that the subject meets all study inclusion criteria and does not meet any of the study exclusion criteria. Enrolled subjects will undergo up to six (6) hemodynamic assessment sessions lasting less than 90 minutes each over the course of their hospitalization. There will be at least eight (8) hours between assessment sessions.
Each assessment session includes recording of the subject's weight, measurements with the reference devices, and measurements with the novel optical system. During the session, the subject will be assessed in the supine, sitting, and standing positions. NT-proBNP measurements will be done at the start of study participation and the end. A market research questionnaire will be administered to the subject following the first measurement session.
研究类型
注册 (实际的)
联系人和位置
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
描述
Inclusion Criteria:
- Age ≥ 18 years
- Admission to the hospital with a primary diagnosis of acute decompensated heart failure
- Treated with or planned treatment with intravenous diuretics
Volume overload, as indicated by at least one of the following clinical signs:
- Peripheral edema
- Pulmonary edema on physical examination
- Pleural effusions on chest x-ray
- Jugular venous distension on physical examination
- CVP > 10 cmH2O
- Presence of third heart sound
- Able to understand study procedures, agree to participate in the study program and voluntarily provide written informed consent
Exclusion Criteria:
- Inability or refusal to sign the Subject Informed Consent
- Age > 80 years
- Body mass index (BMI) > 40
- Planned mechanical ventilation during hospitalization
- Presence of left ventricular assist device (LVAD)
- Dialysis
- Pregnancy. All women of childbearing potential must have a negative pregnancy test before enrollment.
- Parenteral diuretic or other medical treatment for ADHF already administered for more than 12 hours prior to enrollment
- Skin damage to the optical sampling sites (fingers and dorsal hand), to include tattoos, scars, cuts, or burns extending over more than 30% of the visible tissue
- Compromised superficial hand veins or proximal venous stenosis
- Intravenous lines connected to both arms
- Inability to stand with support, if needed, for 4 minutes
- Inability to place hand in the venous imaging enclosure due to forearm, elbow, or shoulder injuries, or other physical constraints
- Inability to wear fingertip or ring sensors on three fingers (of either hand) due to missing fingers, injured fingers, or other physical constraints
- Persons in police custody or prisoners
- Major medical or psychiatric condition that would interfere with the ability to complete the study
学习计划
研究是如何设计的?
设计细节
- 观测模型:队列
- 时间观点:横截面
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Accuracy of Estimated Changes in Stroke Volume
大体时间:Retrospective up to 6 months after study completion
|
Comparison of Stroke Volume Measurement (units of ml) from the optical measurement system with paired Stroke Volume Measurement (ml) from the reference device.
Accuracy will be measured in percentage error and Bland-Altman limits of agreement.
|
Retrospective up to 6 months after study completion
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Accuracy of Central Venous Pressure Measurement
大体时间:Retrospective up to 6 months after study completion
|
Comparison of Central Venous Pressure Measurement (units of cmH2O) from the optical measurement system with paired Central Venous Pressure Measurement (cmH2O) from the reference device.
Accuracy will be measured in percentage error and Bland-Altman limits of agreement.
|
Retrospective up to 6 months after study completion
|
合作者和调查者
调查人员
- 首席研究员:Elena Allen, PhD、Rodin Scientific
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.