Evaluation of the Relationship Between Airway Measurements and Laryngoscopic View in Newborn and Infants
Evaluation of the Relationship Between Airway Measurements With Ultrasonography and Laryngoscopic View in Newborn and Infants
Background and Aim: The overall incidence of difficult laryngoscopy in pediatric anesthesia is lower than in adults, but this risk is higher in patients younger than one year of age. In the last decade, different measurements have been used to obtain difficult laryngoscopy markers in children. In this study, we aimed to evaluate the relationship between the airway measurements (some performed by using ultrasonography (USG)) and the difficult laryngoscopic view in neonates and infants.
Design: This is a prospective, single blinded, observational study. The number of patients was calculated as follows: A sample of 12 from the positive group (difficult laryngoscopy group) and 96 from the negative group (easy laryngoscopy group) achieve 80% power to detect a difference of 0.25 between the area under the ROC curve (AUC) under the null hypothesis of 0.50 and an AUC under the alternative hypothesis of 0,75 using a two-sided z-test at a significance level of 0.05.
Methods: All patients which is newborn and infant age group undergoing elective surgery requiring intubation under general anesthesia are assessed. Patients' age, body mass index (BMI), thyromental distance, mandibula length, the distance between the lip corner and ipsilateral ear tragus, and the transverse length (measured by hand sign-middle-ring fingers adjacent side by side) measurements are recorded. In thyromental distance measurement, "thyroid notch" are determined by USG.
The laryngoscopic view is graded by a different experienced anaesthetist who is blinded to the airway measurements.
Statistical analysis:
Receiver operating characteristic (ROC) curves are used to determine the best cut-off point for distance variables in the separation of difficult and easy laryngoscopy groups. Sensitivity, selectivity, positive predictive value and negative predictive values of lengths are calculated according to determined cut point.The difference between the two groups in terms of qualitative variables are evaluated by chi-square or Fisher's exact test. The normal distribution of the numerical variables are examined with the Shapiro-Wilk test. The difference between the two groups in terms of numerical variables are investigated by Mann Whitney U test. Values of p <0.05 are considered as statistically significant.
研究概览
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
-
Ankara、火鸡、06110
- Ankara Childrens' Health and Diseases Hematology Oncology Training and Research Hospital
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
描述
Inclusion Criteria:
- Newborn and infant age group
- Undergoing elective surgery requiring intubation under general anesthesia
Exclusion Criteria:
- History of congenital maxillofacial defect,
- History of upper airway pathology (tumor, cleft palate-lips, etc.)
- History of head and neck trauma (fracture, swelling, scar )
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
Difficult laryngoscopy (Group D)
Glottic structures appearing during laryngoscopy are graded according to Cormack-Lehane (CL) Classification.
According to this classification, patients are divided into two groups, patients with grade 3-4 are classified as difficult laryngoscopy ( Group D).
|
According to Cormack-Lehane (CL) Classification; laryngoscopic view grade 3-4 is defined as Group D
|
|
Easy laryngoscopy (Group E)
Glottic structures appearing during laryngoscopy are graded according to Cormack-Lehane (CL) Classification.
According to this classification, patients are divided into two groups, patients with grade 1-2 are classified as easy laryngoscopy ( Group E).
|
According to Cormack-Lehane (CL) Classification; laryngoscopic view grade 1-2 is defined as Group E
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Thyromental distance (TMD)
大体时间:1 hour
|
The thyromental distance, unit of measure cm, is detected using a US linear probe with the transducer placed in the transverse plane.
Thyromental distance is measured in cm as straight line from thyroid notch to lower border of mentum with head extended in all patients.
|
1 hour
|
|
Other airway measurements
大体时间:1 hour
|
The other primary objective of this study is to identify if any preanesthetic airway assessment maneuvers (such as mandibula length, the distance between the lip corner and ipsilateral ear tragus, and the transverse length (measured by hand sign-middle-ring fingers adjacent side by side) measurements) would be associated with difficult laryngoscopy in newborn and infants.
|
1 hour
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Demographic data
大体时间:1 hour
|
The secondary objective of this study is to identify if factors such as age, sex, bady mass index (BMI) and physical status grade would be associated with grade III and IV laryngoscope views in newborn and infants.
|
1 hour
|
合作者和调查者
调查人员
- 首席研究员:Feyza Sever、Ankara Children's Health and Diseases Hematology and Oncology Training and Research Hospital
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- 2018105
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.