- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT03920748
Evaluation of the Relationship Between Airway Measurements and Laryngoscopic View in Newborn and Infants
Evaluation of the Relationship Between Airway Measurements With Ultrasonography and Laryngoscopic View in Newborn and Infants
Background and Aim: The overall incidence of difficult laryngoscopy in pediatric anesthesia is lower than in adults, but this risk is higher in patients younger than one year of age. In the last decade, different measurements have been used to obtain difficult laryngoscopy markers in children. In this study, we aimed to evaluate the relationship between the airway measurements (some performed by using ultrasonography (USG)) and the difficult laryngoscopic view in neonates and infants.
Design: This is a prospective, single blinded, observational study. The number of patients was calculated as follows: A sample of 12 from the positive group (difficult laryngoscopy group) and 96 from the negative group (easy laryngoscopy group) achieve 80% power to detect a difference of 0.25 between the area under the ROC curve (AUC) under the null hypothesis of 0.50 and an AUC under the alternative hypothesis of 0,75 using a two-sided z-test at a significance level of 0.05.
Methods: All patients which is newborn and infant age group undergoing elective surgery requiring intubation under general anesthesia are assessed. Patients' age, body mass index (BMI), thyromental distance, mandibula length, the distance between the lip corner and ipsilateral ear tragus, and the transverse length (measured by hand sign-middle-ring fingers adjacent side by side) measurements are recorded. In thyromental distance measurement, "thyroid notch" are determined by USG.
The laryngoscopic view is graded by a different experienced anaesthetist who is blinded to the airway measurements.
Statistical analysis:
Receiver operating characteristic (ROC) curves are used to determine the best cut-off point for distance variables in the separation of difficult and easy laryngoscopy groups. Sensitivity, selectivity, positive predictive value and negative predictive values of lengths are calculated according to determined cut point.The difference between the two groups in terms of qualitative variables are evaluated by chi-square or Fisher's exact test. The normal distribution of the numerical variables are examined with the Shapiro-Wilk test. The difference between the two groups in terms of numerical variables are investigated by Mann Whitney U test. Values of p <0.05 are considered as statistically significant.
Studie Overzicht
Toestand
Interventie / Behandeling
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
-
Ankara, Kalkoen, 06110
- Ankara Childrens' Health and Diseases Hematology Oncology Training and Research Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Newborn and infant age group
- Undergoing elective surgery requiring intubation under general anesthesia
Exclusion Criteria:
- History of congenital maxillofacial defect,
- History of upper airway pathology (tumor, cleft palate-lips, etc.)
- History of head and neck trauma (fracture, swelling, scar )
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Difficult laryngoscopy (Group D)
Glottic structures appearing during laryngoscopy are graded according to Cormack-Lehane (CL) Classification.
According to this classification, patients are divided into two groups, patients with grade 3-4 are classified as difficult laryngoscopy ( Group D).
|
According to Cormack-Lehane (CL) Classification; laryngoscopic view grade 3-4 is defined as Group D
|
|
Easy laryngoscopy (Group E)
Glottic structures appearing during laryngoscopy are graded according to Cormack-Lehane (CL) Classification.
According to this classification, patients are divided into two groups, patients with grade 1-2 are classified as easy laryngoscopy ( Group E).
|
According to Cormack-Lehane (CL) Classification; laryngoscopic view grade 1-2 is defined as Group E
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Thyromental distance (TMD)
Tijdsspanne: 1 hour
|
The thyromental distance, unit of measure cm, is detected using a US linear probe with the transducer placed in the transverse plane.
Thyromental distance is measured in cm as straight line from thyroid notch to lower border of mentum with head extended in all patients.
|
1 hour
|
|
Other airway measurements
Tijdsspanne: 1 hour
|
The other primary objective of this study is to identify if any preanesthetic airway assessment maneuvers (such as mandibula length, the distance between the lip corner and ipsilateral ear tragus, and the transverse length (measured by hand sign-middle-ring fingers adjacent side by side) measurements) would be associated with difficult laryngoscopy in newborn and infants.
|
1 hour
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Demographic data
Tijdsspanne: 1 hour
|
The secondary objective of this study is to identify if factors such as age, sex, bady mass index (BMI) and physical status grade would be associated with grade III and IV laryngoscope views in newborn and infants.
|
1 hour
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Feyza Sever, Ankara Children's Health and Diseases Hematology and Oncology Training and Research Hospital
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- 2018105
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .