Evaluation of the Relationship Between Airway Measurements and Laryngoscopic View in Newborn and Infants
Evaluation of the Relationship Between Airway Measurements With Ultrasonography and Laryngoscopic View in Newborn and Infants
Background and Aim: The overall incidence of difficult laryngoscopy in pediatric anesthesia is lower than in adults, but this risk is higher in patients younger than one year of age. In the last decade, different measurements have been used to obtain difficult laryngoscopy markers in children. In this study, we aimed to evaluate the relationship between the airway measurements (some performed by using ultrasonography (USG)) and the difficult laryngoscopic view in neonates and infants.
Design: This is a prospective, single blinded, observational study. The number of patients was calculated as follows: A sample of 12 from the positive group (difficult laryngoscopy group) and 96 from the negative group (easy laryngoscopy group) achieve 80% power to detect a difference of 0.25 between the area under the ROC curve (AUC) under the null hypothesis of 0.50 and an AUC under the alternative hypothesis of 0,75 using a two-sided z-test at a significance level of 0.05.
Methods: All patients which is newborn and infant age group undergoing elective surgery requiring intubation under general anesthesia are assessed. Patients' age, body mass index (BMI), thyromental distance, mandibula length, the distance between the lip corner and ipsilateral ear tragus, and the transverse length (measured by hand sign-middle-ring fingers adjacent side by side) measurements are recorded. In thyromental distance measurement, "thyroid notch" are determined by USG.
The laryngoscopic view is graded by a different experienced anaesthetist who is blinded to the airway measurements.
Statistical analysis:
Receiver operating characteristic (ROC) curves are used to determine the best cut-off point for distance variables in the separation of difficult and easy laryngoscopy groups. Sensitivity, selectivity, positive predictive value and negative predictive values of lengths are calculated according to determined cut point.The difference between the two groups in terms of qualitative variables are evaluated by chi-square or Fisher's exact test. The normal distribution of the numerical variables are examined with the Shapiro-Wilk test. The difference between the two groups in terms of numerical variables are investigated by Mann Whitney U test. Values of p <0.05 are considered as statistically significant.
Przegląd badań
Status
Interwencja / Leczenie
Typ studiów
Zapisy (Rzeczywisty)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Ankara, Indyk, 06110
- Ankara Childrens' Health and Diseases Hematology Oncology Training and Research Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Newborn and infant age group
- Undergoing elective surgery requiring intubation under general anesthesia
Exclusion Criteria:
- History of congenital maxillofacial defect,
- History of upper airway pathology (tumor, cleft palate-lips, etc.)
- History of head and neck trauma (fracture, swelling, scar )
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Kohorty i interwencje
Grupa / Kohorta |
Interwencja / Leczenie |
|---|---|
|
Difficult laryngoscopy (Group D)
Glottic structures appearing during laryngoscopy are graded according to Cormack-Lehane (CL) Classification.
According to this classification, patients are divided into two groups, patients with grade 3-4 are classified as difficult laryngoscopy ( Group D).
|
According to Cormack-Lehane (CL) Classification; laryngoscopic view grade 3-4 is defined as Group D
|
|
Easy laryngoscopy (Group E)
Glottic structures appearing during laryngoscopy are graded according to Cormack-Lehane (CL) Classification.
According to this classification, patients are divided into two groups, patients with grade 1-2 are classified as easy laryngoscopy ( Group E).
|
According to Cormack-Lehane (CL) Classification; laryngoscopic view grade 1-2 is defined as Group E
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Thyromental distance (TMD)
Ramy czasowe: 1 hour
|
The thyromental distance, unit of measure cm, is detected using a US linear probe with the transducer placed in the transverse plane.
Thyromental distance is measured in cm as straight line from thyroid notch to lower border of mentum with head extended in all patients.
|
1 hour
|
|
Other airway measurements
Ramy czasowe: 1 hour
|
The other primary objective of this study is to identify if any preanesthetic airway assessment maneuvers (such as mandibula length, the distance between the lip corner and ipsilateral ear tragus, and the transverse length (measured by hand sign-middle-ring fingers adjacent side by side) measurements) would be associated with difficult laryngoscopy in newborn and infants.
|
1 hour
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Demographic data
Ramy czasowe: 1 hour
|
The secondary objective of this study is to identify if factors such as age, sex, bady mass index (BMI) and physical status grade would be associated with grade III and IV laryngoscope views in newborn and infants.
|
1 hour
|
Współpracownicy i badacze
Sponsor
Śledczy
- Główny śledczy: Feyza Sever, Ankara Children's Health and Diseases Hematology and Oncology Training and Research Hospital
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Inne numery identyfikacyjne badania
- 2018105
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .