Influence of Contrast Injection Force on the Accuracy of Vessel Measurements in Cerebral Angiography
研究概览
详细说明
Research for this study is to determine how the injection of contrast material influences vessel measurements, as these measurements guide device selection when interventions are warranted.
The data will be used to determine if there is a significant change in vessel diameter with intra-arterial injection of contrast material in cerebral angiography, how changes in force of contrast injection augments the significance of the changes in vessel geometry, and the extent of propagation downstream from the catheter tip that such changes in vessel diameter are detected and found to be significant, as these changes could potentially lead to less optimal device selection by providing an overestimation of true vessel diameter.
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
North Carolina
-
Winston-Salem、North Carolina、美国、27157
- Wake Forest University Health Sciences
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
Patients receiving care at WFBMC that will be undergoing a standard of care cerebral angiogram that are anticipated to have multiple images per standard view (a minimum of 2 images for an individual view required for the necessary data collection).
Patients that are anticipated to have less than 2 images for each standard view collected from their cerebral angiogram.
描述
Inclusion Criteria:
- Patients receiving care at WFBMC that will be undergoing a standard of care cerebral angiogram who are anticipated to have a minimum of 2 images for an individual view required for the necessary data collection
Exclusion Criteria:
- Patients who are anticipated to have less than 2 images for each standard view collected from their cerebral angiogram.
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
Standard of Care Cerebral Angiogram Group
Participants undergoing a standard of care cerebral angiogram.
|
Subjects will undergo the standard of care cerebral angiogram and any intervention(s) (when applicable) that were discussed with their provider, following the standard procedural protocol for the procedure at WFBMC. There are no additional interventions or changes to the planned intervention(s) that will take place by agreeing to participate in the study. The data collected from this procedure, following the standard of care protocol, will include the following: force of injection of contrast material for each angiographic run (peak pressure associated with injection, duration of peak, and area under pressure curve), volume of contrast utilized, images from the procedure, measurements of vessel diameter at defined distances from the catheter tip utilizing the images, catheter type, any additional device(s) (when applicable) utilized during the procedure, and if spasmolytic agents are utilized (including dose and time of administration). |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Peak pressure associated with injection
大体时间:During procedure, up to 10 minutes
|
The effort force of injection will be measured and recorded for each run using a standard arterial line pressure transducer setup that attaches to the guide catheter, with data acquired via Mediocollector (a program that allows for quantitative recording of data.
The duration of peak pressure will be collected.
|
During procedure, up to 10 minutes
|
|
The duration of peak pressure
大体时间:During procedure, up to 10 minutes
|
The duration of peak pressure will be collected.
|
During procedure, up to 10 minutes
|
其他结果措施
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Vessel Diameter
大体时间:During the procedure, up to 10 minutes
|
Measurement of vessel diameter
|
During the procedure, up to 10 minutes
|
合作者和调查者
调查人员
- 首席研究员:Kyle M Fargen, MD, Ph.D、Wake Forest University Health Sciences
出版物和有用的链接
一般刊物
- S P Sutera a, Skalak R. The History of Poiseuille's Law. Annual Review of Fluid Mechanics. 1993;25(1):1-20
- Yousem DM, Trinh BC. Injection rates for neuroangiography: results of a survey. AJNR Am J Neuroradiol. 2001 Nov-Dec;22(10):1838-40.
- Hao Q, Lieber BB. Dispersive Transport of Angiographic Contrast During Antegrade Arterial Injection. Cardiovasc Eng Technol. 2012 Jun 1;3(2):171-178. doi: 10.1007/s13239-012-0090-x. Epub 2012 Apr 13.
- Alexander MD, Nicholson AD, Darflinger RJ, Settecase F, Cooke DL, Dowd CF, Amans MR, Higashida RT, Hetts SW, Halbach VV. Effects on vessel measurement accuracy and subsequent occlusion after calcium channel blocker infusion during treatment of cerebral aneurysms with the Pipeline embolization device. Interv Neuroradiol. 2017 Feb;23(1):47-51. doi: 10.1177/1591019916674916. Epub 2016 Oct 27.
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- IRB00049517
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.