Evaluation of The Effects of Personal Protective Equipment During Airway Management

2021年4月26日 更新者:Kezban Aydan Okuyucu

Evaluation of The Effects of Personal Protective Equipment During Airway Management; A Prospective, Non-randomized, Controlled, Simulation Study

Covid-19 disease has caused a worldwide pandemic. However, it was necessary to reduce the transmission of the disease as much as possible. The highest risk of transmission is airway management. Medical personnel responsible for airway management are at the greatest risk. One of the most important ways to protect anesthetists from contamination is to use PPE. But, it should be considered that there is some disadvantage about using PPE. The investigators aimed to evaluate the effects of the use of personal protective equipment and standard uniform during airway management.

研究概览

详细说明

Objective: The investigators aimed to compare the effects of the use of personal protective equipment and standard uniform during airway management using direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope, I-gel laryngeal mask airway , ProSeal laryngeal mask airway and Frova intubation catheter on the manikin that created both difficult airway and normal airway conditions in the Department of Anesthesiology and Reanimation at the Derince Training and Research Hospital, University of Health Sciences.

Materials and Methods: The study will carry out with 24 participants in Health Sciences University Kocaeli Derince Health Education and Research Center. In the study, a simulation manikin will use to evaluate the effect of personal protective equipment use on airway management. Anesthesia technicians, anesthesia residents and specialists will include as participants. As demographic data, the clinical positions of the participants, their experiences with each airway method and the use of personal protective equipment, age, gender, height and weight information will be recorded. Each procedure will be explained to the participants by an anesthesiology specialist and a resident. Then the participants perform their procedure first with standard uniform and then by wearing personal protective equipment. Endotracheal intubation with direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter followed by I-gel and ProSeal laryngeal mask airway will be used, respectively. Each procedure will be carried out by creating normal and difficult airway conditions, respectively. Time, number of attempts and presence of optimization maneuver will be recorded for each procedure. Modified CLS (Cormack Lehane Score) and POGO (Percentage Of Glottic Opening) scores will be also recorded during intubation procedures. Each participant will be asked to give a score between 1 and 100 using the Visual Analogue Scale (VAS) in order to evaluate the difficulty of intervention after each procedure subjectively and it will be recorded. Finally, the other subjective effects of personal protective equipment using on participants (such as sweating, feeling of warmth) will be asked.

研究类型

观察性的

注册 (实际的)

3

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Kocaeli̇
      • Kocaeli、Kocaeli̇、火鸡、41900
        • Aydan Okuyucu

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人
  • 年长者

接受健康志愿者

是的

有资格学习的性别

全部

取样方法

非概率样本

研究人群

Anesthesiology residents, anesthesiology specialists or anesthesia nurses will be participants in this study.

描述

Inclusion Criteria:

  • Being an anesthesiology resident, specialist or nurse

Exclusion Criteria:

  • Anxiety Disorder
  • Severe heart or lung disease
  • Claustrophobia

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
normal airway manikin with standard uniform
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices
normal airway manikin with personal protective equipment
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices
difficult airway manikin with standard uniform
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices
difficult airway manikin with personal protective equipment
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Evaluation of times
大体时间:2 minutes
For intubations from holding the laryngoscope to ventilation, for laryngeal mask airway insertion from holding the laryngeal mask airway to ventilation For intubation time from holding the laryngoscope to observing glottic opening for standard uniform.
2 minutes
Evaluation of times
大体时间:4 minutes
For intubations from holding the laryngoscope to ventilation, for laryngeal mask airway insertion from holding the laryngeal mask airway to ventilation For intubation time from holding the laryngoscope to observing the glottic opening for personal protective equipment.
4 minutes
Evaluation of number of attempts
大体时间:2 minutes
For both intubation and laryngeal mask airway insertion, number of attempts until ventilation
2 minutes
Evaluation of presence of optimisation maneuver
大体时间:30 seconds
Whether there is optimisation maneuver for each attempt whether there is maneuver for each attempt
30 seconds
Evaluation of Modified Cormack/Lehane classification
大体时间:30 seconds
The classification includes 5 grades; grade 1, 2a, 2b, 3 and 4. Grade 1 defines the best image of glottis.
30 seconds
Evaluation of Percentage of Glottic Opening Scores
大体时间:30 seconds
Percentage of Glottic Opening describes the percentage of the glottic opening as percentages (0-100). Number 100 describes that the participants see all glottic openings. Number 0 describes that nothing is seen.
30 seconds

次要结果测量

结果测量
措施说明
大体时间
Visual Analog Scale of using personal protective equipment
大体时间:15 minutes
The visual analog scale is a scale that converts a subjective property to digital data. It has values between 0-100. Generally it is used for describing pain level. But it is used for describing the difficulty of attempts in this study. Number 0 explains that the attempt is very easy and number 100 is very difficult.
15 minutes

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 研究主任:Mehmet Yilmaz, 2、University of Healt Sciences, Kocaeli Derince Education and Research Hospital

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2021年2月5日

初级完成 (实际的)

2021年2月5日

研究完成 (实际的)

2021年2月7日

研究注册日期

首次提交

2021年1月6日

首先提交符合 QC 标准的

2021年4月26日

首次发布 (实际的)

2021年4月29日

研究记录更新

最后更新发布 (实际的)

2021年4月29日

上次提交的符合 QC 标准的更新

2021年4月26日

最后验证

2021年4月1日

更多信息

与本研究相关的术语

其他研究编号

  • derinceanesteziaydan-1

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.