Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Evaluation of The Effects of Personal Protective Equipment During Airway Management

26 april 2021 uppdaterad av: Kezban Aydan Okuyucu

Evaluation of The Effects of Personal Protective Equipment During Airway Management; A Prospective, Non-randomized, Controlled, Simulation Study

Covid-19 disease has caused a worldwide pandemic. However, it was necessary to reduce the transmission of the disease as much as possible. The highest risk of transmission is airway management. Medical personnel responsible for airway management are at the greatest risk. One of the most important ways to protect anesthetists from contamination is to use PPE. But, it should be considered that there is some disadvantage about using PPE. The investigators aimed to evaluate the effects of the use of personal protective equipment and standard uniform during airway management.

Studieöversikt

Detaljerad beskrivning

Objective: The investigators aimed to compare the effects of the use of personal protective equipment and standard uniform during airway management using direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope, I-gel laryngeal mask airway , ProSeal laryngeal mask airway and Frova intubation catheter on the manikin that created both difficult airway and normal airway conditions in the Department of Anesthesiology and Reanimation at the Derince Training and Research Hospital, University of Health Sciences.

Materials and Methods: The study will carry out with 24 participants in Health Sciences University Kocaeli Derince Health Education and Research Center. In the study, a simulation manikin will use to evaluate the effect of personal protective equipment use on airway management. Anesthesia technicians, anesthesia residents and specialists will include as participants. As demographic data, the clinical positions of the participants, their experiences with each airway method and the use of personal protective equipment, age, gender, height and weight information will be recorded. Each procedure will be explained to the participants by an anesthesiology specialist and a resident. Then the participants perform their procedure first with standard uniform and then by wearing personal protective equipment. Endotracheal intubation with direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter followed by I-gel and ProSeal laryngeal mask airway will be used, respectively. Each procedure will be carried out by creating normal and difficult airway conditions, respectively. Time, number of attempts and presence of optimization maneuver will be recorded for each procedure. Modified CLS (Cormack Lehane Score) and POGO (Percentage Of Glottic Opening) scores will be also recorded during intubation procedures. Each participant will be asked to give a score between 1 and 100 using the Visual Analogue Scale (VAS) in order to evaluate the difficulty of intervention after each procedure subjectively and it will be recorded. Finally, the other subjective effects of personal protective equipment using on participants (such as sweating, feeling of warmth) will be asked.

Studietyp

Observationell

Inskrivning (Faktisk)

3

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • Kocaeli̇
      • Kocaeli, Kocaeli̇, Kalkon, 41900
        • Aydan Okuyucu

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Barn
  • Vuxen
  • Äldre vuxen

Tar emot friska volontärer

Ja

Kön som är behöriga för studier

Allt

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Anesthesiology residents, anesthesiology specialists or anesthesia nurses will be participants in this study.

Beskrivning

Inclusion Criteria:

  • Being an anesthesiology resident, specialist or nurse

Exclusion Criteria:

  • Anxiety Disorder
  • Severe heart or lung disease
  • Claustrophobia

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

Kohorter och interventioner

Grupp / Kohort
Intervention / Behandling
normal airway manikin with standard uniform
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices
normal airway manikin with personal protective equipment
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices
difficult airway manikin with standard uniform
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices
difficult airway manikin with personal protective equipment
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Evaluation of times
Tidsram: 2 minutes
For intubations from holding the laryngoscope to ventilation, for laryngeal mask airway insertion from holding the laryngeal mask airway to ventilation For intubation time from holding the laryngoscope to observing glottic opening for standard uniform.
2 minutes
Evaluation of times
Tidsram: 4 minutes
For intubations from holding the laryngoscope to ventilation, for laryngeal mask airway insertion from holding the laryngeal mask airway to ventilation For intubation time from holding the laryngoscope to observing the glottic opening for personal protective equipment.
4 minutes
Evaluation of number of attempts
Tidsram: 2 minutes
For both intubation and laryngeal mask airway insertion, number of attempts until ventilation
2 minutes
Evaluation of presence of optimisation maneuver
Tidsram: 30 seconds
Whether there is optimisation maneuver for each attempt whether there is maneuver for each attempt
30 seconds
Evaluation of Modified Cormack/Lehane classification
Tidsram: 30 seconds
The classification includes 5 grades; grade 1, 2a, 2b, 3 and 4. Grade 1 defines the best image of glottis.
30 seconds
Evaluation of Percentage of Glottic Opening Scores
Tidsram: 30 seconds
Percentage of Glottic Opening describes the percentage of the glottic opening as percentages (0-100). Number 100 describes that the participants see all glottic openings. Number 0 describes that nothing is seen.
30 seconds

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Visual Analog Scale of using personal protective equipment
Tidsram: 15 minutes
The visual analog scale is a scale that converts a subjective property to digital data. It has values between 0-100. Generally it is used for describing pain level. But it is used for describing the difficulty of attempts in this study. Number 0 explains that the attempt is very easy and number 100 is very difficult.
15 minutes

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Studierektor: Mehmet Yilmaz, 2, University of Healt Sciences, Kocaeli Derince Education and Research Hospital

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

5 februari 2021

Primärt slutförande (Faktisk)

5 februari 2021

Avslutad studie (Faktisk)

7 februari 2021

Studieregistreringsdatum

Först inskickad

6 januari 2021

Först inskickad som uppfyllde QC-kriterierna

26 april 2021

Första postat (Faktisk)

29 april 2021

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

29 april 2021

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

26 april 2021

Senast verifierad

1 april 2021

Mer information

Termer relaterade till denna studie

Andra studie-ID-nummer

  • derinceanesteziaydan-1

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .