Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Evaluation of The Effects of Personal Protective Equipment During Airway Management

26 апреля 2021 г. обновлено: Kezban Aydan Okuyucu

Evaluation of The Effects of Personal Protective Equipment During Airway Management; A Prospective, Non-randomized, Controlled, Simulation Study

Covid-19 disease has caused a worldwide pandemic. However, it was necessary to reduce the transmission of the disease as much as possible. The highest risk of transmission is airway management. Medical personnel responsible for airway management are at the greatest risk. One of the most important ways to protect anesthetists from contamination is to use PPE. But, it should be considered that there is some disadvantage about using PPE. The investigators aimed to evaluate the effects of the use of personal protective equipment and standard uniform during airway management.

Обзор исследования

Подробное описание

Objective: The investigators aimed to compare the effects of the use of personal protective equipment and standard uniform during airway management using direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope, I-gel laryngeal mask airway , ProSeal laryngeal mask airway and Frova intubation catheter on the manikin that created both difficult airway and normal airway conditions in the Department of Anesthesiology and Reanimation at the Derince Training and Research Hospital, University of Health Sciences.

Materials and Methods: The study will carry out with 24 participants in Health Sciences University Kocaeli Derince Health Education and Research Center. In the study, a simulation manikin will use to evaluate the effect of personal protective equipment use on airway management. Anesthesia technicians, anesthesia residents and specialists will include as participants. As demographic data, the clinical positions of the participants, their experiences with each airway method and the use of personal protective equipment, age, gender, height and weight information will be recorded. Each procedure will be explained to the participants by an anesthesiology specialist and a resident. Then the participants perform their procedure first with standard uniform and then by wearing personal protective equipment. Endotracheal intubation with direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter followed by I-gel and ProSeal laryngeal mask airway will be used, respectively. Each procedure will be carried out by creating normal and difficult airway conditions, respectively. Time, number of attempts and presence of optimization maneuver will be recorded for each procedure. Modified CLS (Cormack Lehane Score) and POGO (Percentage Of Glottic Opening) scores will be also recorded during intubation procedures. Each participant will be asked to give a score between 1 and 100 using the Visual Analogue Scale (VAS) in order to evaluate the difficulty of intervention after each procedure subjectively and it will be recorded. Finally, the other subjective effects of personal protective equipment using on participants (such as sweating, feeling of warmth) will be asked.

Тип исследования

Наблюдательный

Регистрация (Действительный)

3

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

    • Kocaeli̇
      • Kocaeli, Kocaeli̇, Турция, 41900
        • Aydan Okuyucu

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Ребенок
  • Взрослый
  • Пожилой взрослый

Принимает здоровых добровольцев

Да

Полы, имеющие право на обучение

Все

Метод выборки

Невероятностная выборка

Исследуемая популяция

Anesthesiology residents, anesthesiology specialists or anesthesia nurses will be participants in this study.

Описание

Inclusion Criteria:

  • Being an anesthesiology resident, specialist or nurse

Exclusion Criteria:

  • Anxiety Disorder
  • Severe heart or lung disease
  • Claustrophobia

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

Когорты и вмешательства

Группа / когорта
Вмешательство/лечение
normal airway manikin with standard uniform
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices
normal airway manikin with personal protective equipment
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices
difficult airway manikin with standard uniform
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices
difficult airway manikin with personal protective equipment
The participants will carry out intubation procedure using macintosh direct laryngoscope, GlideScope video laryngoscope, C-Mac video laryngoscope and Frova intubation catheter and laryngeal mask insertion using ProSeal LMA and I-gel LMA, respectively.
endotracheal intubation and laringeal mask airway insertion on the airway manikin with different devices

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Evaluation of times
Временное ограничение: 2 minutes
For intubations from holding the laryngoscope to ventilation, for laryngeal mask airway insertion from holding the laryngeal mask airway to ventilation For intubation time from holding the laryngoscope to observing glottic opening for standard uniform.
2 minutes
Evaluation of times
Временное ограничение: 4 minutes
For intubations from holding the laryngoscope to ventilation, for laryngeal mask airway insertion from holding the laryngeal mask airway to ventilation For intubation time from holding the laryngoscope to observing the glottic opening for personal protective equipment.
4 minutes
Evaluation of number of attempts
Временное ограничение: 2 minutes
For both intubation and laryngeal mask airway insertion, number of attempts until ventilation
2 minutes
Evaluation of presence of optimisation maneuver
Временное ограничение: 30 seconds
Whether there is optimisation maneuver for each attempt whether there is maneuver for each attempt
30 seconds
Evaluation of Modified Cormack/Lehane classification
Временное ограничение: 30 seconds
The classification includes 5 grades; grade 1, 2a, 2b, 3 and 4. Grade 1 defines the best image of glottis.
30 seconds
Evaluation of Percentage of Glottic Opening Scores
Временное ограничение: 30 seconds
Percentage of Glottic Opening describes the percentage of the glottic opening as percentages (0-100). Number 100 describes that the participants see all glottic openings. Number 0 describes that nothing is seen.
30 seconds

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Visual Analog Scale of using personal protective equipment
Временное ограничение: 15 minutes
The visual analog scale is a scale that converts a subjective property to digital data. It has values between 0-100. Generally it is used for describing pain level. But it is used for describing the difficulty of attempts in this study. Number 0 explains that the attempt is very easy and number 100 is very difficult.
15 minutes

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Следователи

  • Директор по исследованиям: Mehmet Yilmaz, 2, University of Healt Sciences, Kocaeli Derince Education and Research Hospital

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

5 февраля 2021 г.

Первичное завершение (Действительный)

5 февраля 2021 г.

Завершение исследования (Действительный)

7 февраля 2021 г.

Даты регистрации исследования

Первый отправленный

6 января 2021 г.

Впервые представлено, что соответствует критериям контроля качества

26 апреля 2021 г.

Первый опубликованный (Действительный)

29 апреля 2021 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

29 апреля 2021 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

26 апреля 2021 г.

Последняя проверка

1 апреля 2021 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • derinceanesteziaydan-1

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕТ

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться