此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Blood Flow Quantification Near Stented SFA Lesions Using Ultrasound Velocimetry (EchoPIV in SFA)

2021年6月21日 更新者:Rijnstate Hospital

Feasibility of Ultrasound Particle Image Velocimetry to Quantify Flow Near Stented SFA Lesions

Peripheral arterial disease (PAD) in the lower extremity is the third leading cause of atherosclerotic cardiovascular morbidity. Endovascular treatment has become the principal surgical strategy in femoro-popliteal lesions. Stent placement induces significant changes in the arterial geometry and thereby in the hemodynamic environment. Visualization of local blood flow patterns (around stents) is challenging, but clinically relevant. Blood flow has a significant influence on the development of atherosclerosis and therefore stent patency. In vivo blood flow characterization might enable the recognition, prediction and explanation of (in-stent) restenosis. This study will therefore aim to investigate the feasibility of a novel ultrasound technique (echoPIV) to quantify spatiotemporal blood flow near stented femoral artery lesions. Furthermore, the blood flow information obtained during the echoPIV measurements will be used as patient-specific boundary conditions in a computational fluid dynamics (CFD) simulation. The tested hypothesis is that blood flow quantification using echoPIV is feasible in and around stents in the femoral artery and that it will improve CFD simulations.

研究概览

研究类型

观察性的

注册 (实际的)

20

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Gelderland
      • Arnhem、Gelderland、荷兰
        • Rijnstate Hospital

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

非概率样本

研究人群

Patients with peripheral arterial disease who have been treated with a stent placement in the superficial femoral artery.

描述

Inclusion Criteria:

  • Scheduled endovascular treatment of a lesion in the SFA through placement of a bare metal or a covered stent
  • A recently (<6 weeks) treated lesion in the SFA through placement of a bare metal or a covered stent

Exclusion Criteria:

  • Hypersensitivity to the active substance(s) or any of the excipients in SonoVue
  • Right-to-left cardiac shunt
  • Severe pulmonary hypertension (pulmonary artery pressure > 90mmHg)
  • Uncontrolled systemic hypertension
  • Adult respiratory distress syndrome
  • Severe pulmonary disease (e.g. COPD GOLD 3/4, adult respiratory distress syndrome)
  • Clinically unstable cardiac disease (recent or ongoing myocardial infarction, unstable angina at rest, recent percutaneous coronary intervention, clinically worsening cardiac symptoms, severe cardiac arrythmia's, endocarditis, etc.)
  • Prosthetic valves
  • Loss of renal function (GFR < 31 ml/min), end-stage renal disease
  • End-stage liver disease Sepsis
  • Hypercoagulable status, recent thrombosis
  • Congestive heart failure (class III or IV)
  • Hypersensitivity to iodinated contrast media
  • Pregnancy

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
PAD patients
The entire cohort exists of patients recently treated with an endovascular stent placement in the superficial femoral artery (SFA).
Patients will undergo high-frame-rate contrast-enhanced ultrasound measurements, within 6 to 8 weeks after the endovascular procedure, at the vascular center of Rijnstate hospital. Prior to these measurements a venous cannula will be placed to ensure venous access for the contrast administration.
Patients will undergo a CTA scan of the lower extremities at the Radiology dept. of Rijnstate hospital the same day as the echoPIV measurements. This CTA scan serves as a reference for the vessel geometry and stent location.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Qualitative assessment vector velocity fields
大体时间:6 to 8 weeks after the procedure (stent placement of SFA)
Vector velocity fields derived from the echoPIV data will be used to calculate and visualize the velocity profile. In order to answer the question regarding feasibility of echoPIV the quality of the vector velocity fields will be assessed using three different metrics of which the first one is a qualitative assessment by different observers. Recordings of the contrast-enhanced ultrasound with an overlay of the vector velocity profiles will be reviewed on different topics following a scoring rubrics.
6 to 8 weeks after the procedure (stent placement of SFA)
Contrast-to-background ratio
大体时间:6 to 8 weeks after the procedure (stent placement of SFA)
The contrast-to-background ratio (CBR) is the second metric to assess the outcomes of the echoPIV measurements. The CBR is a quantitative measure for the contrast levels and therefore for the quality of the contrast-enhanced US image. The higher the CBR level (in dB) the higher the intensity of the contrast which is needed for sufficient PIV analysis.
6 to 8 weeks after the procedure (stent placement of SFA)
Vector correlation
大体时间:6 to 8 weeks after the procedure (stent placement of SFA)
The vector correlation is the third metric to assess the outcomes of the echoPIV measurements. The vector correlation demonstrates the tracking performance of the PIV algorithm. The vector correlation provides a unitless value between 0 and 1 in which 0 indicates poor tracking of the microbubble contrast and 1 indicates perfect tracking of the microbubble contrast.
6 to 8 weeks after the procedure (stent placement of SFA)

次要结果测量

结果测量
措施说明
大体时间
Vorticity
大体时间:6 to 8 weeks after the procedure (stent placement of SFA)
Multiple blood flow parameters will be derived from the echoPIV data. The first one is the vorticity, or the curl of the velocity. The vorticity represents the rotation of particles inside the flow field. This measure can potentially be used to define regions with disturbed blood flow, as a high value (in rad/s) indicates the occurence of a recirculation.
6 to 8 weeks after the procedure (stent placement of SFA)
Vector complexity
大体时间:6 to 8 weeks after the procedure (stent placement of SFA)
The second blood flow parameters derived from the echoPIV data is the vector complexity. Vector complexity is a measure of multi-directional flow, ranging from 0 till 1. a value of 1 means complex flow with all velocity vectors pointing in all directions, whereas a value of 0 means laminar flow with all velocity vectors pointing in the same direction. This measure can potentially be used to indicate regions with disturbed blood flow.
6 to 8 weeks after the procedure (stent placement of SFA)
Correlation echoPIV and CFD
大体时间:6 to 8 weeks after the procedure (stent placement of SFA)
Velocity profiles obtained with echoPIV will be compared to outcomes of a computational fluid dynamics (CFD) simulation model of the femoral artery. Multiple points along the imaged vessel will be selected in both the echoPIV and the CFD data to extract the temporal velocity profile. This profile will be compared point-by-point after which the correlation between both outcomes/techniques will be obtained.
6 to 8 weeks after the procedure (stent placement of SFA)

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Michel MPJ Reijnen, PhD、Dept. of Surgery, Rijnstate Hospital Arnhem

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2018年8月8日

初级完成 (实际的)

2019年8月30日

研究完成 (实际的)

2019年8月30日

研究注册日期

首次提交

2021年6月10日

首先提交符合 QC 标准的

2021年6月21日

首次发布 (实际的)

2021年6月22日

研究记录更新

最后更新发布 (实际的)

2021年6月22日

上次提交的符合 QC 标准的更新

2021年6月21日

最后验证

2021年6月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅