Comparison of Age-Based Formula and Ultrasound-Guided Subglottic Diameter Measurement for Endotracheal Tube Sizing
Comparison of Age-Based Formula and Ultrasound-Guided Subglottic Diameter Measurement for Endotracheal Tube Sizing in Single Ventricle Patients
研究概览
详细说明
To compare the accuracy of ultrasound-guided subglottic diameter measurement versus age-based formulas in determining optimal ETT size in pediatric patients with single ventricle physiology to avoid post-extubation complications. All legal guardians will provide written informed consent after a full explanation of the study. During the pre-anesthetic evaluation, demographic data, ASA physical status, relevant comorbidities, and a recent echocardiogram confirming single ventricle physiology will be documented. In the operating room, patients will be monitored using standard ASA monitors including ECG, non-invasive blood pressure, pulse oximetry, and capnography, followed by preoxygenation with 100% oxygen. If intravenous access is available, anesthesia will be induced with ketamine, fentanyl, and rocuronium. If IV access is not available, inhalational induction with sevoflurane will be used until IV access is secured, after which fentanyl and rocuronium will be administered. Following induction, ventilation will continue with FiO₂ 100% and sevoflurane 1.5% for 3 minutes.
Patients will be divided into two groups:
Group A (Age-Based Formula):
In neonates and infants under 1 year, a weight-based sizing is used:
- Infants <1 kg (Preterm): 2.5 mm ETT
- Infants 1-2 kg: 3 mm ETT
- Infants 2-3 kg (Full Term): 3-3.5 mm ETT
- Infants >3 kg (3 months to 1 year): 3.5-4 mm ETT
In Infants > 1 year, ETT size will be selected based on the standard formula: Cole's Formula for uncuffed ETT.
ETT ID (mm) = (Age/4) + 4.
Group B (Ultrasound Group):
During mask ventilation, a trained anesthesiologist will perform transverse subglottic diameter measurement using a high-frequency linear ultrasound probe (7-15 MHz). The patient will be positioned supine with mild neck extension. The probe will be placed transversely just below the thyroid cartilage to identify the subglottic airway at the level of the cricoid cartilage. The measured diameter (in mm) will be recorded and used to determine ETT size from the equation:
ETT ID (mm) = Subglottic diameter (mm) × 0.8 To confirm appropriate ETT sizing, all patients will be placed on pressure-controlled mechanical ventilation and a leak test will be performed in both groups. Start with pressure 20-25 cm H₂O, if there is resistance to ETT passage into the trachea or no audible leak or ventilator-detected leak when the lungs are inflated, the tube will be exchanged for one that is 0.5 mm smaller. If a leak is detected, decrease the pressure to 10 cm H₂O. If there's still a detected leak at 10 cm H₂O, the ETT will be exchanged for one that is 0.5 mm larger. If there's no leak at 10 cm H₂O then the ETT is optimal. Tube size will be considered optimal when a tracheal leak is not detected at an inflation pressure between 10-20 cm H₂O with uncuffed tubes.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Nouran Nemr, M.B.B.Ch, M.Sc.
- 电话号码:01008558583
- 邮箱:Nourannemr@med.asu.edu.eg
研究联系人备份
- 姓名:Mohamed Tolba, MD
- 电话号码:01156622298
学习地点
-
-
Abbasseya
-
Cairo、Abbasseya、埃及、00202
- 招聘中
- Ain Shams University
-
接触:
- Nouran Nemr, M.B.B.Ch, M.Sc.
- 电话号码:01008558583
- 邮箱:Nourannemr@med.asu.edu.eg
-
-
参与标准
资格标准
适合学习的年龄
- 孩子
接受健康志愿者
描述
Inclusion Criteria:
- Pediatric patients (3 months to 8 years)
- Patients with single ventricle physiology
- Scheduled for Glenn or Fontan surgery or cardiac catheterization
- Patients with Glenn or Fontan shunt scheduled for surgery
Exclusion Criteria:
- Refusal of legal guardians
- Emergency surgery
- Patients with tracheostomy tubes
- Recent or active upper respiratory tract infection
- Airway anomalies (e.g. Pierre Robin, Treacher Collins)
- ICU stay due to complications other than that of airway
学习计划
研究是如何设计的?
设计细节
- 主要用途:其他
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:Age-Based Formula Group
In neonates and infants under 1 year, a weight-based sizing is used:
ETT ID (mm) = (Age/4) + 4. |
Subglottic diameter in mm x 0.8
|
|
有源比较器:Ultrasound Group
During mask ventilation, a trained anesthesiologist will perform transverse subglottic diameter measurement using a high-frequency linear ultrasound probe (7-15 MHz). The patient will be positioned supine with mild neck extension. The probe will be placed transversely just below the thyroid cartilage to identify the subglottic airway at the level of the cricoid cartilage. The measured diameter (in mm) will be recorded and used to determine ETT size from the equation: ETT ID (mm) = Subglottic diameter (mm) × 0.8 |
Using Ultrasound for accuracy of ETT sizing
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Accuracy of ETT size selection
大体时间:During endotracheal intubation, immediately after induction of anesthesia and neuromuscular blockade (within 10 minutes after induction)
|
Accuracy of endotracheal tube size selection measured by the number of ETT attempts required to achieve an appropriate leak test and successful airway placement.
|
During endotracheal intubation, immediately after induction of anesthesia and neuromuscular blockade (within 10 minutes after induction)
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Incidence of post-extubation stridor/croup
大体时间:From extubation until 24 hours post-extubation
|
Occurrence of post-extubation stridor or croup assessed using the Westley croup score.
|
From extubation until 24 hours post-extubation
|
|
Severity of post-extubation croup
大体时间:At 30 minutes, 2 hours, and 24 hours after extubation
|
Severity of post-extubation croup assessed using the Westley croup score
|
At 30 minutes, 2 hours, and 24 hours after extubation
|
|
Duration of ICU stay related to airway complications
大体时间:From ICU admission until ICU discharge, up to 30 days
|
Length of ICU stay due to airway complications such as post-extubation stridor
|
From ICU admission until ICU discharge, up to 30 days
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.