Volumetric Visual Fields at Intermediate and Near Distances in Presbyopic Patients Using Occupational and General-Purpose Progressive Addition Lenses (CIVIUS2025PAL)
Ensayo clínico, unicéntrico, Transversal, Randomizado, Cruzado, Doble Ciego Para Evaluar Las Diferencias de Los Campos volumétricos de visión en Distancia Intermedia (4m) y Cerca (25cm) de Tres Tipos de Lentes oftálmicas de adición Progresiva (PAL), Dos de visión Intermedia y Cerca (PC-PAL) y Otra Generalista de Vision Lejos, Intermedia y Cerca (GPPAL), Neutros en Vision de Lejos y de 2.00 D en Vision de Cerca en Pacientes présbitas.
This single-center, randomized, double-blind, crossover clinical trial aims to compare the volumetric visual fields provided by two occupational progressive addition lenses (OPLs) optimized for intermediate and near vision in presbyopic patients. The study evaluates Vimax Zoom 1.5 FWD 4 m and Vimax PC 1.5 FWD 4 m lenses and Vimax Fit FRM, all of them with plano distance power and a +2.00 D near addition, in order to determine differences in the extent of clear vision at multiple working distances.
Participants will undergo a comprehensive optometric examination including medical and ocular history, visual acuity assessment, accommodative amplitude measurement, autorefraction, interpupillary distance measurement, ocular motility evaluation, confrontation visual fields, Amsler grid testing, and binocular vision assessment. Visual field measurements will then be performed using both study lenses under standardized conditions. Subjects will be instructed to maintain a fixed head position while identifying optotypes located at distances of 4 m, 2 m, 1.33 m, 80 cm, 40 cm, and 25 cm. Both lenses will be tested in random order under masked conditions so that neither participants nor investigators know which lens design is being evaluated during each phase.
At least 23 presbyopic participants are expected to be enrolled. The study procedures are non-invasive and are anticipated to be completed in a single one-hour visit, although additional sessions may be scheduled if necessary. No significant risks are expected beyond possible transient visual fatigue associated with the duration of testing.
The primary objective is to determine which occupational progressive lens design provides a greater spatial volume of clear vision and wider horizontal and vertical visual fields at different intermediate and near distances. The findings may contribute to improving personalized recommendations of occupational lenses according to patients' visual demands and working distances.
研究概览
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Sevilla
-
Seville、Sevilla、西班牙、41012
- Pharmacy school, University of Seville
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Spherical ametropia for distance vision ≤ ±4.00 D and astigmatic ametropia ≤ 1.00 D.
- Decimal VA ≥ 0.8, either uncorrected (UCVA) or corrected (BCVA) with monofocal contact lenses.
- Patients with a nasopupillary distance (NPD) of 31 mm, with a tolerance of ±2 mm in each eye
Exclusion Criteria:
- Astigmatism greater than ±1.00 D.
- Patients wearing progressive contact lenses.
- Patients who have undergone cataract surgery or have monofocal or multifocal intraocular lenses.
- Anisometropia greater than 2.50 D.
- Decimal distance visual acuity < 0.8 (UCVA or BCVA) with monofocal contact lenses.
- Patients without normal ocular motility or with partial dysfunction of one or more ex-traocular muscles, or with restricted visual fields or scotomas.
- Visual suppression in one eye between 4 m and 25 cm.
- Strabismus or nystagmus.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:双倍的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:OPL designed for PC use
VIMAX PC: Occupational progressive lenses designed to provide clear vision from 400 cm to 40 cm, with a wider visual field optimized for monitor-based environments with a depth of field between 60 and 80 cm.
These lenses, designated L1, were custom ordered with neutral distance power and a near addition of +2.00 D, a vertex distance of 13 mm, pantoscopic tilt of 8°, wrap angle of 6°, working distance of 40 cm, inset of 2.5 mm in both eyes, and NPD of 31 mm in each eye.
|
Fitting and positioning of the spectacles : participants were instructed to move only their eyes and to verbally identify the letters indicated by the optometrist. Measurement of clear vision limits: the horizontal and vertical boundaries of clear vision were recorded on a scaled results sheet, as defined by the participant using the optotype, at distances of 400, 200, 133, 80, 40, and 25 cm, in that order |
|
实验性的:OPL designed for office use
VIMAX ZOOM: Occupational progressive lenses also designed to provide clear vision from 400 cm to 40 cm, but with a more homogeneous distribution of the visual field across office and home environments, with a depth of field between 40 and 400 cm.
These lenses, designated L2, were also custom ordered with neutral distance power and a near addition of +2.00 D, vertex distance of 13 mm, pantoscopic tilt of 8°, wrap angle of 6°, working distance of 40 cm, inset of 2.5 mm in both eyes, and NPD of 31 mm in both eyes.
|
Fitting and positioning of the spectacles : participants were instructed to move only their eyes and to verbally identify the letters indicated by the optometrist. Measurement of clear vision limits: the horizontal and vertical boundaries of clear vision were recorded on a scaled results sheet, as defined by the participant using the optotype, at distances of 400, 200, 133, 80, 40, and 25 cm, in that order |
|
有源比较器:PAL
VIMAX FIT: Progressive additional lenses custom ordered with neutral distance power and a near addition of +2.00 D, vertex dis-tance of 13 mm, pantoscopic tilt of 8°, wrap angle of 6°, working distance of 40 cm, inset of 2.5 mm in both eyes, and NPD of 31 mm in both eyes.
|
Fitting and positioning of the spectacles : participants were instructed to move only their eyes and to verbally identify the letters indicated by the optometrist. Measurement of clear vision limits: the horizontal and vertical boundaries of clear vision were recorded on a scaled results sheet, as defined by the participant using the optotype, at distances of 400, 200, 133, 80, 40, and 25 cm, in that order |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Visual field volume
大体时间:Immediately after the adjustment of the frame where the lenses were placed, an average of 30 minutes per patient.
|
It will consist of the volume defined by two parallel surfaces bounded by the visual fields perceived with clear horizontal and vertical vision by the patient between the distances of 4 m and 25 cm while wearing each pair of spectacles.
The volume will be calculated using the Heronian formula for the volume of a quadrangular pyramidal frustum.
|
Immediately after the adjustment of the frame where the lenses were placed, an average of 30 minutes per patient.
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Visual fields surface
大体时间:Immediately after the adjustment of the frame where the lenses were placed, an average of 30 minutes per patient.
|
Calculation of the visual field surface areas defined by the patient with each lens type at distances of 4 m, 2 m, 1.33 m, 80 cm, 40 cm, and 25 cm.
For this purpose, the areas corresponding to the visual field regions of the lens located between the fitting cross and the intermediate and near viewing zones were summed in a 1:2 proportion, respectively, for each measured distance.
|
Immediately after the adjustment of the frame where the lenses were placed, an average of 30 minutes per patient.
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- CIVIUS2025PAL
- SICEIA-2025-001629 (其他标识符:SICEIA: Ethics Committee for Biomedics Research of the Junta de Andalucia)
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
在美国制造并从美国出口的产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.