Volumetric Visual Fields at Intermediate and Near Distances in Presbyopic Patients Using Occupational and General-Purpose Progressive Addition Lenses (CIVIUS2025PAL)

23 mei 2026 bijgewerkt door: José Manuel Serrano Morales, University of Seville

Ensayo clínico, unicéntrico, Transversal, Randomizado, Cruzado, Doble Ciego Para Evaluar Las Diferencias de Los Campos volumétricos de visión en Distancia Intermedia (4m) y Cerca (25cm) de Tres Tipos de Lentes oftálmicas de adición Progresiva (PAL), Dos de visión Intermedia y Cerca (PC-PAL) y Otra Generalista de Vision Lejos, Intermedia y Cerca (GPPAL), Neutros en Vision de Lejos y de 2.00 D en Vision de Cerca en Pacientes présbitas.

This single-center, randomized, double-blind, crossover clinical trial aims to compare the volumetric visual fields provided by two occupational progressive addition lenses (OPLs) optimized for intermediate and near vision in presbyopic patients. The study evaluates Vimax Zoom 1.5 FWD 4 m and Vimax PC 1.5 FWD 4 m lenses and Vimax Fit FRM, all of them with plano distance power and a +2.00 D near addition, in order to determine differences in the extent of clear vision at multiple working distances.

Participants will undergo a comprehensive optometric examination including medical and ocular history, visual acuity assessment, accommodative amplitude measurement, autorefraction, interpupillary distance measurement, ocular motility evaluation, confrontation visual fields, Amsler grid testing, and binocular vision assessment. Visual field measurements will then be performed using both study lenses under standardized conditions. Subjects will be instructed to maintain a fixed head position while identifying optotypes located at distances of 4 m, 2 m, 1.33 m, 80 cm, 40 cm, and 25 cm. Both lenses will be tested in random order under masked conditions so that neither participants nor investigators know which lens design is being evaluated during each phase.

At least 23 presbyopic participants are expected to be enrolled. The study procedures are non-invasive and are anticipated to be completed in a single one-hour visit, although additional sessions may be scheduled if necessary. No significant risks are expected beyond possible transient visual fatigue associated with the duration of testing.

The primary objective is to determine which occupational progressive lens design provides a greater spatial volume of clear vision and wider horizontal and vertical visual fields at different intermediate and near distances. The findings may contribute to improving personalized recommendations of occupational lenses according to patients' visual demands and working distances.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Werkelijk)

26

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Sevilla
      • Seville, Sevilla, Spanje, 41012
        • Pharmacy school, University of Seville

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Ja

Beschrijving

Inclusion Criteria:

  • Spherical ametropia for distance vision ≤ ±4.00 D and astigmatic ametropia ≤ 1.00 D.
  • Decimal VA ≥ 0.8, either uncorrected (UCVA) or corrected (BCVA) with monofocal contact lenses.
  • Patients with a nasopupillary distance (NPD) of 31 mm, with a tolerance of ±2 mm in each eye

Exclusion Criteria:

  • Astigmatism greater than ±1.00 D.
  • Patients wearing progressive contact lenses.
  • Patients who have undergone cataract surgery or have monofocal or multifocal intraocular lenses.
  • Anisometropia greater than 2.50 D.
  • Decimal distance visual acuity < 0.8 (UCVA or BCVA) with monofocal contact lenses.
  • Patients without normal ocular motility or with partial dysfunction of one or more ex-traocular muscles, or with restricted visual fields or scotomas.
  • Visual suppression in one eye between 4 m and 25 cm.
  • Strabismus or nystagmus.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Crossover-opdracht
  • Masker: Dubbele

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: OPL designed for PC use
VIMAX PC: Occupational progressive lenses designed to provide clear vision from 400 cm to 40 cm, with a wider visual field optimized for monitor-based environments with a depth of field between 60 and 80 cm. These lenses, designated L1, were custom ordered with neutral distance power and a near addition of +2.00 D, a vertex distance of 13 mm, pantoscopic tilt of 8°, wrap angle of 6°, working distance of 40 cm, inset of 2.5 mm in both eyes, and NPD of 31 mm in each eye.

Fitting and positioning of the spectacles : participants were instructed to move only their eyes and to verbally identify the letters indicated by the optometrist.

Measurement of clear vision limits: the horizontal and vertical boundaries of clear vision were recorded on a scaled results sheet, as defined by the participant using the optotype, at distances of 400, 200, 133, 80, 40, and 25 cm, in that order

Experimenteel: OPL designed for office use
VIMAX ZOOM: Occupational progressive lenses also designed to provide clear vision from 400 cm to 40 cm, but with a more homogeneous distribution of the visual field across office and home environments, with a depth of field between 40 and 400 cm. These lenses, designated L2, were also custom ordered with neutral distance power and a near addition of +2.00 D, vertex distance of 13 mm, pantoscopic tilt of 8°, wrap angle of 6°, working distance of 40 cm, inset of 2.5 mm in both eyes, and NPD of 31 mm in both eyes.

Fitting and positioning of the spectacles : participants were instructed to move only their eyes and to verbally identify the letters indicated by the optometrist.

Measurement of clear vision limits: the horizontal and vertical boundaries of clear vision were recorded on a scaled results sheet, as defined by the participant using the optotype, at distances of 400, 200, 133, 80, 40, and 25 cm, in that order

Actieve vergelijker: PAL
VIMAX FIT: Progressive additional lenses custom ordered with neutral distance power and a near addition of +2.00 D, vertex dis-tance of 13 mm, pantoscopic tilt of 8°, wrap angle of 6°, working distance of 40 cm, inset of 2.5 mm in both eyes, and NPD of 31 mm in both eyes.

Fitting and positioning of the spectacles : participants were instructed to move only their eyes and to verbally identify the letters indicated by the optometrist.

Measurement of clear vision limits: the horizontal and vertical boundaries of clear vision were recorded on a scaled results sheet, as defined by the participant using the optotype, at distances of 400, 200, 133, 80, 40, and 25 cm, in that order

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Visual field volume
Tijdsspanne: Immediately after the adjustment of the frame where the lenses were placed, an average of 30 minutes per patient.
It will consist of the volume defined by two parallel surfaces bounded by the visual fields perceived with clear horizontal and vertical vision by the patient between the distances of 4 m and 25 cm while wearing each pair of spectacles. The volume will be calculated using the Heronian formula for the volume of a quadrangular pyramidal frustum.
Immediately after the adjustment of the frame where the lenses were placed, an average of 30 minutes per patient.

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Visual fields surface
Tijdsspanne: Immediately after the adjustment of the frame where the lenses were placed, an average of 30 minutes per patient.
Calculation of the visual field surface areas defined by the patient with each lens type at distances of 4 m, 2 m, 1.33 m, 80 cm, 40 cm, and 25 cm. For this purpose, the areas corresponding to the visual field regions of the lens located between the fitting cross and the intermediate and near viewing zones were summed in a 1:2 proportion, respectively, for each measured distance.
Immediately after the adjustment of the frame where the lenses were placed, an average of 30 minutes per patient.

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

29 september 2025

Primaire voltooiing (Werkelijk)

28 november 2025

Studie voltooiing (Geschat)

1 september 2026

Studieregistratiedata

Eerst ingediend

14 mei 2026

Eerst ingediend dat voldeed aan de QC-criteria

23 mei 2026

Eerst geplaatst (Werkelijk)

1 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

1 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

23 mei 2026

Laatst geverifieerd

1 mei 2026

Meer informatie

Termen gerelateerd aan deze studie

Aanvullende relevante MeSH-voorwaarden

Andere studie-ID-nummers

  • CIVIUS2025PAL
  • SICEIA-2025-001629 (Andere identificatie: SICEIA: Ethics Committee for Biomedics Research of the Junta de Andalucia)

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

product vervaardigd in en geëxporteerd uit de V.S.

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .