此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Effect of Different Resin Composite Packing Techniques on Pulp Condition (Randomized Clinical Trial)

2026年7月4日 更新者:Esraa Mohamed Zaki、October 6 University

The goal of this clinical trial is to evalute the effect of different resin composite packing techniques on pulpal condition in patient with deep carious occlusal cavities in their molar teeth. The main questions it aims to answer are:

  • Do composite packing technquies cause pulpal inflammatory response ?
  • Do composite packing technquies cause post operative pain ? Researchers will compare elastic cavity liner packing techniques to sonic activated and flowable bulk packing techniques to see their effect on pulp condition.

Participants will :

  • Provide an honest medial and dental history to undergo the restorative procedures .
  • Report subjective symptons.
  • Attend all scheduled follow-ups visit for pulp assessment.

研究概览

详细说明

This clinical study evaluates the impact of various resin composite packing techniques on pulp inflammation and post-operative condition, specifically comparing the biological and mechanical outcomes of incremental layering of packable composite with flowable liner versus modern bulk-fill strategies as SoniFill bulk fill resin composite and SDR bulk fill composite. The research involves preparing standardized cavities in clinical participants and restoring them using specialized resin materials to determine how different application methods influence polymerization shrinkage stress, marginal adaptation, and dentinal tubule fluid movement. To quantify the subclinical inflammatory response of the pulp, Gingival Crevicular Fluid (GCF) samples are collected from the gingival sulcus of the restored teeth at baseline and specific post-operative intervals (immediately and after one week ) to analyze changes in inflammatory mediators or biomarkers. Simultaneously, the patient's subjective experience of post-operative pain and thermal sensitivity is recorded using the Visual Analog Scale (VAS), where participants mark their level of discomfort on a 10-cm line to provide measurable data on clinical symptoms. By correlating these objective biochemical markers from the GCF with the subjective VAS scores and clinical sensibility testing, the study aims to identify the most effective packing protocol for minimizing C-factor-related stress and protecting the dentin-pulp complex from inflammatory responses.

研究类型

介入性

注册 (实际的)

30

阶段

  • 第四阶段

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Giza、埃及、3235142
        • Ain Shams University

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人

接受健康志愿者

不

描述

Inclusion Criteria:

  • Both genders.
  • Systemically healthy patients.
  • Good oral hygiene.
  • Available for follow-up appointments.
  • Asymptomatic permanent molars with deep occlusal caries ICDAS 5 or 6 carious lesions and healthy periodontium, in normal occlusion with no previous restorations related to the teeth and vital with a positive response to cold testing.

Exclusion Criteria:

  • Vulnerable populations.
  • Tobacco users.
  • Medically compromised patients, such as those with diabetes or medications affecting salivary flow were excluded.
  • Teeth with prior endodontic treatment, periodontal pockets over 3 mm, or any dental/periodontal therapy within the past 12 months.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:双倍的

武器和干预

参与者组/臂
干预/治疗
无干预:Flowable liner and packable composite
Following proper administration of local anesthesia , cavity preparation is completed according to the study's standardized dimensions. Isolation is achieved using a rubber dam to ensure a moisture-free operating field. Selective-etch is performed using 37% phosphoric acid, followed by thorough rinsing and gentle air-drying to leave the dentin moist. The bonding agent is applied according to the manufacturer's instructions, gently air-thinned to form a uniform layer, and light-cured for the specified duration. A low-viscosity flowable composite liner is applied to the pulpal floor generally not exceeding 1-2 mm in thickness. he remaining cavity depth is restored using a packable resin composite using an incremental layering technique to minimize polymerization shrinkage stress. Each increment is meticulously adapted to the cavity walls using a hand plugger, anatomically contoured, and light-cured individually from the occlusal surface.
实验性的:Sonic Fill bulk fill resin composite

The SonicFill bulk-fill resin composite is delivered directly into the cavity preparation using its specialized, ultrasonically activated handpiece.

The material is placed in a single bulk increment of up to 5 mm, completely filling the cavity to the occlusal margin. Once the sonic activation stops, the material reverts to a sculptable, non-slumping consistency, allowing immediate anatomical contouring. The entire bulk increment is then light-cured from the occlusal surface according to the manufacturer's recommended exposure time and intensity.

The SonicFill bulk-fill resin composite is delivered directly into the cavity preparation using its specialized, ultrasonically activated handpiece. The material is placed in a single bulk increment of up to 5 mm, completely filling the cavity to the occlusal margin. Once the sonic activation stops, the material reverts to a sculptable, non-slumping consistency, allowing immediate anatomical contouring. The entire bulk increment is then light-cured from the occlusal surface according to the manufacturer's recommended exposure time and intensity
实验性的:SDR flowable bulk fill resin composite

SDR bulk-fill flowable composite is dispensed directly into the cavity using the manufacturer's syringe tip, starting from the deepest part of the preparation to avoid air entrapment. Due to its self-leveling properties and low polymerization stress, it is placed in a single bulk increment of up to 4 mm, leaving approximately 1.5-2 mm of occlusal space for the capping layer. The material is then light-cured.

The remaining occlusal volume is restored using a conventional packable resin composite to act as the wear-resistant enamel replacement. Then the capping layer is adapted to the cavosurface margins, anatomically contoured to replicate correct tooth morphology, and light-cured.

SDR bulk-fill flowable composite is dispensed directly into the cavity using the manufacturer's syringe tip, starting from the deepest part of the preparation to avoid air entrapment. Due to its self-leveling properties and low polymerization stress, it is placed in a single bulk increment of up to 4 mm, leaving approximately 1.5-2 mm of occlusal space for the capping layer. The material is then light-cured. The remaining occlusal volume is restored using a conventional packable resin composite to act as the wear-resistant enamel replacement. Then the capping layer is adapted to the cavosurface margins, anatomically contoured to replicate correct tooth morphology, and light-cured.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Pulpal inflammatory responses.
大体时间:From enrollment to the end of treatment at one year.
Immuno-histological analysis of the crevicular fluid to evalute pulpal inflammatory response by quantifying the volume of the pro-inflammatory cytokine TNF-α in GCF that reflect pulpal inflmmation in response to different resin composite packing techniques.
From enrollment to the end of treatment at one year.

次要结果测量

结果测量
措施说明
大体时间
Post-operative pain.
大体时间:From enrollment to the end of treatment at one year.
This evaluation is conducted using the Visual Analog Scale (VAS), a validated 10-cm horizontal line where "0" represents "no pain" and "10" represents "the worst imaginable pain." Participants are instructed to record their subjective perception of discomfort at specific post-operative intervals (before treatment and one week following restorative procedures ). To ensure a comprehensive assessment, pain is categorized into spontaneous pain and provoked pain (sensitivity to thermal stimuli or masticatory pressure). This subjective data is then correlated with the biochemical findings from the Gingival Crevicular Fluid (GCF) samples.
From enrollment to the end of treatment at one year.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2025年2月1日

初级完成 (实际的)

2026年1月1日

研究完成 (实际的)

2026年1月1日

研究注册日期

首次提交

2026年7月4日

首先提交符合 QC 标准的

2026年7月4日

首次发布 (实际的)

2026年7月10日

研究记录更新

最后更新发布 (实际的)

2026年7月10日

上次提交的符合 QC 标准的更新

2026年7月4日

最后验证

2026年7月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.