Intraocular Lens Power Calculation After Laser Refractive Surgery Based on Optical Coherence Tomography (OCT IOL)

February 8, 2024 updated by: David Huang, Oregon Health and Science University

Guiding the Treatment of Anterior Eye Diseases With Optical Coherence Tomography

The long-term goal of this project is to utilize very high-speed optical coherence tomography (OCT) technology to guide surgical treatments of corneal diseases. OCT is well known for its exquisite resolution, but until recently it has not had sufficient speed to capture the shape of the cornea because of eye motion during OCT scanning. The development of Fourier-domain (FD) OCT technology has made the requisite speed possible.

The objective of this project is to develop methods for imaging the cornea with an FD-OCT system that will precisely measure corneal shape and use this information to guide surgery. Cataract surgery in patients with previous laser vision correction often leads to significant near- or far-sightedness, a problem that could be resolved by using a more accurate intraocular lens power selection formula based on the measurement of corneal refractive power with OCT.

Study Overview

Status

Recruiting

Conditions

Intervention / Treatment

Detailed Description

This study is about an imaging method called Optical Coherence Tomography (OCT) which provides detailed cross-sectional (layered) views of structures in the eye. The OCT system scans a beam of light across the eye to take a picture. OCT provides a more detailed image than other imaging methods of the eye such as ultrasound, CT scan (computed tomography) and MRI (magnetic resonance imaging). In addition, OCT imaging does not touch the eye. OCT is routinely used in imaging structures in the back of the eye (retina) and cornea. This study uses high-speed FDA approved OCT systems. The proposed research plan is a combination of clinical studies and software development to be performed synergistically. Clinical studies will provide OCT images for image processing software development and testing. The image processing software will provide automated measurement of anatomic parameters essential for clinical use.

Cataract extraction and IOL implantation is the most common eye surgery. The power of the IOL implant is calculated from 2 measurements: the axial eye length (AL) and keratometric power (K). The Holladay II formula also uses the external corneal diameter ("white-to-white" or WTW) and anterior chamber depth (ACD). These formulae work well (±0.5D) in normal eyes. However, these formulae can leads to biased and unpredictable refractive results in eyes that had refractive surgery procedures such as LASIK, PRK, and RK. With a large number of patients undergoing refractive surgery every year, the problem is becoming more severe.

The conventional IOL formulae fail because several inherent assumptions are no longer true in the eye that had refractive surgery. These assumptions are: 1) The corneal refractive power is uniform. 2) The anterior and posterior corneal power has a fixed relationship such that the overall corneal refractive power can be calculated from the anterior keratometry (or topography) using the keratometric index. 3) The position of IOL can be predicted by K with or without additional information such as WTW and ACD.

Relative to the posterior curvature, the anterior curvature becomes flatter after myopic correction and steeper after hyperopic correction with LASIK or PRK. To adapt the conventional IOL formulae to this situation, most surgeons use rigid contact lens over-refraction to calculate an "effective K." However, the accuracy of refraction in cataract patients is poor due to poor vision. Alternatively, one could use a historical method to calculate the effective K from pre-refractive surgery values. However, those measurements are often no longer available. If many years have lapsed, the historical value may no longer accurately reflect the current shape of the cornea.

The axial position of the IOL is determined by the positions of lens zonules and capsule which is in turn related to the corneal curvature (K) in the normal eye. A flatter cornea (lower K) is usually associated with a larger anterior segment, where the lens apparatus is located further back. A more complex model that also uses a separately measured white-to-white corneal diameter may be even more accurate. In post-refractive surgery eyes, however, K is altered and no longer has the normal relationship with the size of the eye. One way to get around this is to enter the pre-refractive surgery K. However, this historical information is not always available. We believe that a better solution would be use an entirely different approach that does not depend on the 3 above assumptions at all. Since OCT can separately measure the corneal anterior and posterior surfaces and AC and lens dimensions, we believe it has the potential of being the basis of a much better IOL calculation formula.

Previously we developed a method to measure both anterior and posterior corneal surface curvatures and obtain more accurate corneal power measurements than conventional keratometry, which only measures the anterior surface. This was the basis of an OCT-based intraocular lens (IOL) formula that showed better results than other formulas for post-myopic LASIK cataract surgery. However, this formula was only on par with the best regression-based formulas in eyes with previous hyperopic LASIK or radial keratectomy (RK), because IOL position prediction error and higher-order corneal aberration limited the accuracy of optical calculations in in these cases. We propose to improve IOL position prediction by using the long-range OCT that can image the entire anterior eye and accurately measure the lens equatorial position. We propose to more accurately determine corneal power in the presence of high aberration by developing ray tracing techniques based on ultrahigh-speed OCT mapping of corneal surfaces. Together, these new methods should improve IOL selection and refractive outcome for all types of eyes. In addition, we will develop a new OCT-based toric IOL formula that takes into account posterior corneal astigmatism, which is ignored in conventional keratometry.

Study Type

Observational

Enrollment (Estimated)

690

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Study Locations

    • Oregon
      • Portland, Oregon, United States, 97239
        • Recruiting
        • Casey Eye Institute, Oregon Health & Science University
        • Contact:
        • Contact:
        • Principal Investigator:
          • David Huang, MD, PhD
        • Sub-Investigator:
          • Winston Chamberlain, MD, PhD
        • Sub-Investigator:
          • Afshan Nanji, MD
        • Sub-Investigator:
          • Richard Stutzman, MD
        • Sub-Investigator:
          • Yan Li, PhD
        • Sub-Investigator:
          • Ellen Davis, MD
        • Sub-Investigator:
          • Seema Gupta, MD

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Sampling Method

Probability Sample

Study Population

patients seeking cataract surgery with implantation of monofocal IOLs (including toric IOLs) but not multifocal or accommodative IOLs.

Description

Inclusion Criteria:

  • The subjects will be patients seeking cataract surgery with implantation of monofocal IOLs (including toric IOLs) but not multifocal or accommodative IOLs.
  • Subjects will have had post-laser vision correction (LVC) such as previous LASIK, PRK, laser sub-epithelial keratectomy (LASEK), epi-LASIK (surface laser ablation under a microkeratome-created epithelial flap) or RK. The post-LVC group will be subdivided into those who have previous hyperopic LVC and those who have previous myopic LVC.

Exclusion Criteria:

  • Inability to give informed consent.
  • Inability to maintain stable fixation for OCT imaging.
  • Inability to commit to required visits to complete the study.
  • Eyes with concurrent cataract, retinal diseases, glaucoma, or other eye conditions that may limit the visual outcome after surgery.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
IOL power prediction (baseline visit)
Time Frame: Study enrollment
Subjects will be assessed at study enrollment, and a prediction of the most suitable IOL power will be made. Predicted IOL power will be measured in Diopters.
Study enrollment
IOL power prediction error (post-operative visit)
Time Frame: No later than 6-months following cataract surgery.
Subjects will be assessed no later than 6-months following cataract surgery to assess accuracy of IOL power prediction at baseline visit. IOL power error will be measured in Diopters.
No later than 6-months following cataract surgery.

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: David Huang, MD, PhD, Casey Eye Institute, Oregon Health & Science University

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

April 1, 2011

Primary Completion (Estimated)

July 1, 2026

Study Completion (Estimated)

July 1, 2026

Study Registration Dates

First Submitted

September 18, 2007

First Submitted That Met QC Criteria

September 18, 2007

First Posted (Estimated)

September 19, 2007

Study Record Updates

Last Update Posted (Actual)

February 12, 2024

Last Update Submitted That Met QC Criteria

February 8, 2024

Last Verified

February 1, 2024

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • OHSU IRB #00006612-IOL
  • 7R01EY018184-04 (U.S. NIH Grant/Contract)

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe