Near Infrared Spectroscopy for Blood Glucose Measurement in Critical Care Settings

July 21, 2010 updated by: InLight Solutions
Luminous Medical, the Sponsor is developing a glucose monitor for the critical care setting. The Sponsor's ultimate goal is to provide a near-continuous blood glucose monitor that automatically measures glucose. In this study, Luminous will evaluate the performance of the near-infrared measurement in blood samples collected from patients in the intensive care unit setting.

Study Overview

Status

Completed

Conditions

Detailed Description

Maintenance of tight glycemic control in critically ill patients has been demonstrated to significantly reduce morbidity and mortality in critical care patients in the OR and ICU settings. Numerous (>20) peer-reviewed publications have demonstrated the benefits of tight glycemic control. For example, tight glycemic control has been shown to reduce surgical site infections by 60% in cardiothoracic surgery patients (Furnary et al., 1999), and has been shown to reduce overall ICU mortality by 40% with significant reductions in ICU morbidity and length of stay (Van den Berghe, 2001).

Historically, caregivers treated hyperglycemia (high blood glucose) only when glucose levels exceeded 220 mg/dL. However, based upon these recent clinical findings, experts now recommend controlling blood glucose to within the normoglycemic range (80-110 mg/dL). Adherence to such strict glucose control regimens requires near-continuous monitoring of blood glucose and frequent adjustment of insulin infusion to achieve normoglycemia while avoiding risk of hypoglycemia (low blood glucose). Surveys indicate that, in response to this demonstrated clinical need, more than 50% of US hospitals have now adopted tight glycemic control protocols for some critical care patients, with an additional 23% expected to adopt such protocols within the next 12 months.

Currently, these TGC protocols require intravenous administration of insulin to achieve and manage glucose control to within the normoglycemic range. The protocols also mandate frequent monitoring of patient blood glucose levels by nursing staff. With existing technology, each test involves removal of a blood sample and testing on handheld meters or blood gas analyzers. This process is cumbersome, labor intensive, and often disruptive to the patient. Although hospitals are responding to the identified clinical need, current technology has limited adoption due to two principal reasons:

  1. Fear of hypoglycemia: administering insulin to maintain the patient in the target glucose range of 80-110 mg/dL exposes the patient to increased risk clinical hypoglycemia (blood glucose less than 50 mg/dL). Critical care patients are often sedated and do not exhibit typical signs of hypoglycemia, exacerbating the risk of hypoglycemia. The need for frequent monitoring and concern about risk of hypoglycemia increase caregiver stress and can limit adherence to tight glycemic control protocols.
  2. Glucose monitoring by conventional methods represents a burdensome procedure: most tight glycemic control protocols require frequent glucose monitoring and insulin adjustment at 30 minute to 2 hour intervals (typically hourly) to avoid hypoglycemia while maintaining normoglycemia. Glucose determination with current technology (including instrument preparation, blood sample acquisition and instrument analysis) typically takes 5 minutes per measurement.

The Sponsor is developing an automated patient-attached blood glucose monitor that will automatically make frequent blood glucose measurements. Frequent measurements will allow better tracking of patient glucose status and will provide blood glucose trend information. The system will alert caregivers to impending or actual hypoglycemia conditions. Automation will reduce the labor burden associated with existing technology. The device is intended to help caregivers to better manage tight glycemic control in their patients.

The device measures glucose in whole blood by flowing a patient blood sample through an optical flow cell while transmitting near infrared light through the sample. The blood constituents, including glucose, absorb a portion of the near-infrared energy in characteristic fashion. The instrument measures the resulting transmission spectrum and analyzes the spectrum to determine the concentration of glucose in the blood sample.

Though the proposed study will represent the initial measurements made by the device in ICU patients, the Sponsor has collected data in volunteer studies conducted at InLight's facility. In one study, we collected blood from volunteer donors and created individual blood samples with variable glucose (glucose range 50-550 mg/dL) by spiking the samples with concentrated glucose solution. We also induced hematocrit variation between 30-50% in these samples by controlling the red cell to plasma ratio. Spectral measurements collected with the prototype device were mathematically correlated with simultaneous blood glucose measurements of the same samples obtained with a Yellow Springs Instruments YSI 2700 Select glucose analyzer (an industry-standard laboratory glucose analyzer) to generate a spectral glucose model and to provide baseline near-infrared glucose measurement results. This evaluation demonstrated that the device's glucose measurements tracked the YSI 2700 glucose measurements with an accuracy of 8.9 mg/dL (1 s.d.). See Figure 1.

In another study, we collected serial blood samples from 5 volunteer subjects with diabetes undergoing dynamic glucose changes induced by carbohydrate ingestion and insulin administration. We obtained spectral glucose measurements of the blood samples using the prototype near-infrared device and compared them with simultaneous blood glucose measurements of the same samples obtained with the YSI 2700 Select glucose analyzer. The Sponsor's results compared favorably with the YSI 2700 results, demonstrating a root-mean-squared error (1 standard deviation) of 5.9 mg/dL (Figure 2). This accuracy level is comparable to current handheld meter technology.

We anticipate that the OR and ICU environments will present new physiological and pharmacological challenges for our instrument. The proposed study is essentially a screening study that will give the Sponsor insight into these challenges. Access to the de-identified ICU charts will allow the Sponsor to correlate the glucose measurements and measurement errors with specific pharmacologic therapies and physiological events. In this manner, the proposed study is in effect a screening study.

Study Type

Observational

Enrollment (Anticipated)

50

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • New Mexico
      • Albuquerque, New Mexico, United States, 87106
        • InLight Solutions

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

i. Sample size is to include up to 50 subjects ii. Group will include nondiabetics as well as people with Type I and Type II diabetes.

iii. Group will nominally be half male, half female. iv. Subjects must be 18 years or older to participate.

Description

Inclusion Criteria:

i. 18 years of age or older ii. Bodyweight greater than 100 lbs iii. Hematocrit > 28% iv. Must not be pregnant v. Must have a pre-existing blood access line

Exclusion Criteria:

i. Rare blood type or antibodies identified ii. Minor status (less than 18 yrs of age) iii. Bodyweight < 100 lbs (45.45 kg) iv. Hematocrit < 28%

1. Blood samples will not be collected for study purposes if a patient's hematocrit drops below 28%.

v. Limited autonomy vi. Enrollment in other studies requiring large volume blood sampling vii. Pregnancy viii. Jehovah's witness ix. Unavailability of an existing arterial or venous access line was placed for the scheduled procedure in the volunteer. An access line will not be placed for the sole purpose of this study.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Collaborators

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

April 1, 2008

Primary Completion (ACTUAL)

April 1, 2008

Study Completion (ACTUAL)

April 1, 2008

Study Registration Dates

First Submitted

July 21, 2010

First Submitted That Met QC Criteria

July 21, 2010

First Posted (ESTIMATE)

July 22, 2010

Study Record Updates

Last Update Posted (ESTIMATE)

July 22, 2010

Last Update Submitted That Met QC Criteria

July 21, 2010

Last Verified

February 1, 2008

More Information

Terms related to this study

Other Study ID Numbers

  • ILS-06-078

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Critical Care

3
Subscribe