Reliability And Validity Of The Usage Of The Camry Dynamometer In Healthy Adults
Comparing the Outcome Measures of the Camry and Jamar Dynamometers in Healthy Adult Individuals and Investigating the Realiability and Validity of the Camry Usage.
Jamar hydraulic hand dynamometer, is a high cost and manual device that is commonly used for the evaluation of the hand grip strength (HGS) with validity and reliability. Nowadays it is thought that usage of the digital and automatic calibration dynamometers, such as Camry, would be more appropriate in the evaluation of the HGS.
This research is a cross-sectional study using the random crossover method. Purpose of the study is comparing the outcome measures of the Camry and Jamar dynamometers in healthy adult individuals and investigating the realiability and validity of the Camry usage.
Healthy adult male and female individuals aged 18 and over will be included in the study on a voluntary basis. Power analysis was performed to determine the number of people to be included in the study. The power of the test was calculated with the G*Power 3.1 program and was determined as 60 participants. Inclusion criteria of the study; Healthy adults aged 18 and over, individuals who do not have any restrictions in upper extremity functions and do not have cognitive and/or psychological problems will be included. Individuals under 18 years of age, using an assistive device, having an autoimmune disorder, pregnant individuals, and individuals with a history of hospitalization for more than three days in the last six months will not be included in the study.
Study Overview
Detailed Description
Evaluation and Measurements Evaluations and measurements will be made by the same researchers as stated below. The aim of the measurements to be made is to compare the Camry and Jamar dynamometers in evaluating grip strength.
1. Patient Information and Evaluation Form 2. Camry Electronic Hand Grip Dynamometer - Measurement of Grip Force 3. Jamar Hydraulic Hand Grip Dynamometer - Measurement of Grip Force The evaluations to be applied to the participants included in the study will be recorded instantly. Each individual's grip strength will be measured with two different dynamometers (Camry Electronic and Jamar Hydraulic Hand Grip Dynamometer). Evaluations will be made bilaterally (right and left) in the upper extremity, and there will be a one-minute rest period between each repeat measurement.
- Participant Information and Evaluation Form: This is an evaluation form that includes the patient's demographic information such as name, surname, age, gender, weight, height, body mass index and dominant upper extremity side information.
- Camry Electronic Hand Grip Dynamometer - Measurement of Grip Strength: In the evaluation to be made with the Camry Electronic Hand Grip Dynamometer; Three different measurements will be made on bilateral upper extremities (right and left). The average of three different evaluated measurements will be taken and recorded. There will be a one-minute rest period between each repeat measurement. In the evaluations to be made, the individual's posture; feet in a comfortable position at shoulder-width distance, shoulders in neutral rotation-vertical adduction, elbow joint in 90° flexion and forearm in neutral position, wrist in 0°-30° extension and 0° to 15° ulnar deviation. After the individual's posture is established, individuals will be asked to make maximum grasping movements.
Jamar Hydraulic Hand Grip Dynamometer - Measurement of Grip Strength: In the evaluation to be made with the Jamar Hydraulic Hand Grip Dynamometer; Three different measurements will be made on bilateral upper extremities (right and left). The average of three different evaluated measurements will be taken and recorded. There will be a one-minute rest period between each repeat measurement. In the evaluations to be made, the individual's posture; feet in a comfortable position at shoulder-width distance, shoulders in neutral rotation-vertical adduction, elbow joint in 90° flexion and forearm in neutral position, wrist in 0°-30° extension and 0° to 15° ulnar deviation. After the individual's posture is established, individuals will be asked to make maximum grasping movements.
Study Type
Enrollment (Actual)
Contacts and Locations
Study Locations
-
-
Beykoz
-
Istanbul, Beykoz, Turkey, 34810
- Istanbul Medipol University
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Healthy participants older than 18, without an upper extremity surgery, fracture history or any limitation of the upper extremity functions as appropriate for the inclusion criterias.
Exclusion Criteria:
- Participants who has any cognitive, psychologic or autoimmune disorder, using an assistive device, hospital stay history for more than three days within the last six months and/or pregnant were not included in the study.
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of hand grip strength with Camry dynamometer
Time Frame: 10 minute
|
In the literature, although it is stated that the hand grip strength (HGS)is related with the general muscle strength and physical activity level, also thought to be an indicator of the general health.
The HGS evaluation in all healthy and/or sick individuals is important for the clinical follow up or evaluation purposes.
In our study, the Camry dynamometer, which has automatic calibration, automatic grip strength data recording and continuous data collection, will be used to evaluate HGS.
|
10 minute
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of hand grip strength with Jamar dynamometer
Time Frame: 10 minute
|
Hand grip strength (HCP) is among the commonly preferred methods in evaluating the general health of the body and muscle strength.
Jamar hydraulic hand dynamometer is recommended by the American Association of Hand Therapists (ASHT) to evaluate grip strength.
The Jamar dynamometer, used in clinics and research, is a gold standard tool with reliability and validity used in the evaluation of hand grip strength.
For this reason, Jamar hydraulic hand dynamometer will be used to evaluate the participants' secondary hand grip strength.
The results of the Camry dynamometer, which we use to evaluate general health and hand grip strength, will be compared with the measurement results of the Jamar hydraulic hand dynamometer.
|
10 minute
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: SENA Ö GÖRGÜ, Istanbul Medipol Universty
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Estimated)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- Istanbul Medipol Universty
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Hand Grasp
-
Ahi Evran University Education and Research HospitalAtılım UniversityUnknown
-
Riphah International UniversityNot yet recruiting
-
Universidad Autonoma de MadridCentro Universitario La SalleUnknown
-
Cairo UniversityNot yet recruiting
-
October 6 UniversityActive, not recruitingBurns | Hand Injuries | Hand Burn | Hand GraspEgypt
-
Loma Linda UniversityCompleted
-
Central Park Medical CollegeShalamar Teaching HospitalCompletedPregnancy Related | Hand GraspPakistan
-
Fondazione Don Carlo Gnocchi OnlusUnknown
-
National Cheng-Kung University HospitalCompletedStroke | Rehabilitation | Hand Grasp
Clinical Trials on Assessment
-
Istanbul University - CerrahpasaCompletedHealthy | Physical InactivityTurkey
-
Gazi UniversityUnknownPhysical Functional Performance | Postural Balance | Complete Tear, Ankle, Lateral LigamentTurkey
-
Saglik Bilimleri UniversitesiNot yet recruitingPain Management | Anxiety Depression | Patient Satisfaction | Voice Quality | Laryngeal Carcinoma | Swallowing Function | Quality of Life (QOL)
-
Çankırı Karatekin UniversityHacettepe UniversityCompleted
-
Assistance Publique - Hôpitaux de ParisURC Necker Cochin, FranceCompletedShock | Cerebral Lesion | Arterial HypotensionFrance
-
McGill UniversityCompletedCommunication | Gait | Emotions | MusicCanada
-
Hacettepe UniversityNot yet recruitingAnxiety | Pain, Chronic | Grip | Muscle Disorder
-
Çankırı Karatekin UniversityCompletedCognitive Dysfunction | Aging | Motor Skills DisordersTurkey
-
University Hospital, ToursRecruitingNeurophysiological Study of Sensory and Cognitive Processes in Healthy Children and Adults (PROSCEA)Healthy VolunteerFrance
-
Centre Hospitalier Universitaire de la RéunionCompletedChikungunya Virus InfectionRéunion