Reliability And Validity Of The Usage Of The Camry Dynamometer In Healthy Adults

February 20, 2024 updated by: sena ozdemir

Comparing the Outcome Measures of the Camry and Jamar Dynamometers in Healthy Adult Individuals and Investigating the Realiability and Validity of the Camry Usage.

Jamar hydraulic hand dynamometer, is a high cost and manual device that is commonly used for the evaluation of the hand grip strength (HGS) with validity and reliability. Nowadays it is thought that usage of the digital and automatic calibration dynamometers, such as Camry, would be more appropriate in the evaluation of the HGS.

This research is a cross-sectional study using the random crossover method. Purpose of the study is comparing the outcome measures of the Camry and Jamar dynamometers in healthy adult individuals and investigating the realiability and validity of the Camry usage.

Healthy adult male and female individuals aged 18 and over will be included in the study on a voluntary basis. Power analysis was performed to determine the number of people to be included in the study. The power of the test was calculated with the G*Power 3.1 program and was determined as 60 participants. Inclusion criteria of the study; Healthy adults aged 18 and over, individuals who do not have any restrictions in upper extremity functions and do not have cognitive and/or psychological problems will be included. Individuals under 18 years of age, using an assistive device, having an autoimmune disorder, pregnant individuals, and individuals with a history of hospitalization for more than three days in the last six months will not be included in the study.

Study Overview

Status

Completed

Conditions

Intervention / Treatment

Detailed Description

Evaluation and Measurements Evaluations and measurements will be made by the same researchers as stated below. The aim of the measurements to be made is to compare the Camry and Jamar dynamometers in evaluating grip strength.

1. Patient Information and Evaluation Form 2. Camry Electronic Hand Grip Dynamometer - Measurement of Grip Force 3. Jamar Hydraulic Hand Grip Dynamometer - Measurement of Grip Force The evaluations to be applied to the participants included in the study will be recorded instantly. Each individual's grip strength will be measured with two different dynamometers (Camry Electronic and Jamar Hydraulic Hand Grip Dynamometer). Evaluations will be made bilaterally (right and left) in the upper extremity, and there will be a one-minute rest period between each repeat measurement.

  1. Participant Information and Evaluation Form: This is an evaluation form that includes the patient's demographic information such as name, surname, age, gender, weight, height, body mass index and dominant upper extremity side information.
  2. Camry Electronic Hand Grip Dynamometer - Measurement of Grip Strength: In the evaluation to be made with the Camry Electronic Hand Grip Dynamometer; Three different measurements will be made on bilateral upper extremities (right and left). The average of three different evaluated measurements will be taken and recorded. There will be a one-minute rest period between each repeat measurement. In the evaluations to be made, the individual's posture; feet in a comfortable position at shoulder-width distance, shoulders in neutral rotation-vertical adduction, elbow joint in 90° flexion and forearm in neutral position, wrist in 0°-30° extension and 0° to 15° ulnar deviation. After the individual's posture is established, individuals will be asked to make maximum grasping movements.

Jamar Hydraulic Hand Grip Dynamometer - Measurement of Grip Strength: In the evaluation to be made with the Jamar Hydraulic Hand Grip Dynamometer; Three different measurements will be made on bilateral upper extremities (right and left). The average of three different evaluated measurements will be taken and recorded. There will be a one-minute rest period between each repeat measurement. In the evaluations to be made, the individual's posture; feet in a comfortable position at shoulder-width distance, shoulders in neutral rotation-vertical adduction, elbow joint in 90° flexion and forearm in neutral position, wrist in 0°-30° extension and 0° to 15° ulnar deviation. After the individual's posture is established, individuals will be asked to make maximum grasping movements.

Study Type

Observational

Enrollment (Actual)

78

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Beykoz
      • Istanbul, Beykoz, Turkey, 34810
        • Istanbul Medipol University

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

Yes

Sampling Method

Non-Probability Sample

Study Population

The participants of this study will be healthy male and female individuals aged 18 and over who agree to participate voluntarily.

Description

Inclusion Criteria:

  • Healthy participants older than 18, without an upper extremity surgery, fracture history or any limitation of the upper extremity functions as appropriate for the inclusion criterias.

Exclusion Criteria:

  • Participants who has any cognitive, psychologic or autoimmune disorder, using an assistive device, hospital stay history for more than three days within the last six months and/or pregnant were not included in the study.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Evaluation of hand grip strength with Camry dynamometer
Time Frame: 10 minute
In the literature, although it is stated that the hand grip strength (HGS)is related with the general muscle strength and physical activity level, also thought to be an indicator of the general health. The HGS evaluation in all healthy and/or sick individuals is important for the clinical follow up or evaluation purposes. In our study, the Camry dynamometer, which has automatic calibration, automatic grip strength data recording and continuous data collection, will be used to evaluate HGS.
10 minute

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Evaluation of hand grip strength with Jamar dynamometer
Time Frame: 10 minute
Hand grip strength (HCP) is among the commonly preferred methods in evaluating the general health of the body and muscle strength. Jamar hydraulic hand dynamometer is recommended by the American Association of Hand Therapists (ASHT) to evaluate grip strength. The Jamar dynamometer, used in clinics and research, is a gold standard tool with reliability and validity used in the evaluation of hand grip strength. For this reason, Jamar hydraulic hand dynamometer will be used to evaluate the participants' secondary hand grip strength. The results of the Camry dynamometer, which we use to evaluate general health and hand grip strength, will be compared with the measurement results of the Jamar hydraulic hand dynamometer.
10 minute

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Principal Investigator: SENA Ö GÖRGÜ, Istanbul Medipol Universty

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

November 20, 2023

Primary Completion (Actual)

December 4, 2023

Study Completion (Actual)

December 13, 2023

Study Registration Dates

First Submitted

October 24, 2023

First Submitted That Met QC Criteria

November 8, 2023

First Posted (Actual)

November 13, 2023

Study Record Updates

Last Update Posted (Estimated)

February 21, 2024

Last Update Submitted That Met QC Criteria

February 20, 2024

Last Verified

February 1, 2024

More Information

Terms related to this study

Other Study ID Numbers

  • Istanbul Medipol Universty

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Hand Grasp

Clinical Trials on Assessment

Subscribe