Can Wearable Technology be Used to Predict Exercise Intensity ((CWTPEI))

June 9, 2026 updated by: Keele University

Developing a Rationale for the Use of Breathing Frequency and Wearable Foot-pods to Measure Intensity in Cardiac Populations

There is a knowledge gap in the literature around using watts to measure exercise intensity in walking and running, this is largely due to new technological developments. Whereas the relationship is widely recognised and used for cycling in elite to clinical populations.

While the relationship breathing rate and exercise intensity is well established, this are no guidelines using breathing rate as a physiological measure of intensity. New technology may aid to bridge these gaps.

The main aims of the study are: -

Can the relationship between oxygen uptake and watts during incremental exercise Can breathing frequency be used to determine aerobic exercise intensity

The participants will complete two 9 minute incremental accredited exercise tests on the flat around cones and on treadmill at the given speed of walking around the cones. The test will stop at 6.8kph or at participant volition.

Study Overview

Status

Not yet recruiting

Detailed Description

The experimental feasibility study involves testing if the wearable technology (Stryd accelerometer) can translate work rate into an accurate measurement of watts (energy produced) within cardiac populations, when compared to V̇o2 consumed. While also testing to see the measured relationship between breathing rate and exercise induced exertion levels. The testing will involve participants working to a sub maximal incremental shuttle walk test pace on treadmill (unto 6.8kph) and following standard procedure on the flat around cones. They will be wearing a Stryd accelerometer attached to their training shoes and Respa breathing monitor attached to their lapel or t-shirt. V̇o2 will be measured using a Cortex Metalyzer 3B. All participants will perform the testing twice in a counter balanced order (i.e participant one will perform the treadmill first, while the next will perform the testing on the flat around cones).

Participants will be recruited from the cardiac rehabilitation team at the University Hospital of the North Midlands.

The pace of the treadmill will be in line with the constant walking pace required to achieve a steady state at each level of the incremental shuttle walk test protocol. The treadmill will not be an incline as normal testing is on flat surface. The Stryd and Respa will be linked to a mobile device where watts and breathing frequency readings will be gathered, progression to the next stage will be at one minute.

Each test lasts for 9 minutes, with a 15-minute recovery period between tests and pre and post exercise tests, participation will take approximately 1 hour. Post testing the participant can remove the device and face mask; while being encouraged to cool down until heart rate is within 20 beats of resting levels but they can leave at any time.

Power will be measured in watts from the Stryd accelerometer, V̇O2 will be measured in ml.kg.min, while respiratory rate will be breaths per minute To remove anomalies from the excel sheet, the watts and breathing frequency readings will be taken from smoothing the data within the last 30 seconds of the level. This will allow the participant to adjust to the change in pace and achieve a steady state of walking. The V̇o2 reading will also be taken in the last 30 seconds with the average of the smoothed data used.

It is anticipated that all participants will not finish the testing up to stage 9, due to volitional fatigue. All data will be reported and recorded, with a n value for each stage, denoting the power and the perceived drop out at each point.

Study Type

Observational

Enrollment (Estimated)

24

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Sampling Method

Probability Sample

Study Population

Participants must have suffered an myocardial infraction in the last 6 months and be actively participating in the cardiac rehabilitation programme at the University Hospital of North Midlands in the United Kingdom

Description

Inclusion Criteria:

  • Myocardial Infraction in the past 6 months
  • Able to walk on a treadmill
  • Aged ≥ 18

Exclusion Criteria:

• Injury or condition that impedes normal gait

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Myocardial Infraction
Participants who have suffered a myocardial infraction in the past 6 months and are actively enrolled onto a cardiac rehabilitation programme
The participants will walk on the flat around cones placed 9 meters apart inline with the procedure for the incremental shuttle walk test. They will also walk at a matched speed to the incremental shuttle walk test on a treadmill. This will be performed in a counter balanced procedure to reduce any benefit of a learning effect.
Other Names:
  • ISWT

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Can a Stryd accelerometer be used to predict V̇o2max and therefore be used to gather a baseline for exercise prescription in cardiac populations post myocardial infraction.
Time Frame: 1 day of testing, enrolment may be within 1 month prior to the test
Develop a regression equation for the use of watts derived from a foot pod to predict vo2. Assessing watts per kg of body mass against vo2 per kg of body mass, offering insight as to how this population group can use watts to prescribe exercise.
1 day of testing, enrolment may be within 1 month prior to the test

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Can a breathing frequency monitor be used to predict aerobic exercise intensity in cardiac populations post myocardial infraction.
Time Frame: 1 day of testing, enrolment may be within 1 month prior to the test
Develop a regression equation for the use of breathing frequency to predict vo2. Assessing breathing frequency against vo2 per kg of body mass, offering insight as to how this population group can use watts to prescribe exercise.
1 day of testing, enrolment may be within 1 month prior to the test

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Study Chair: John Buckley, PhD, Keele University

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

October 1, 2026

Primary Completion (Estimated)

January 31, 2027

Study Completion (Estimated)

June 30, 2027

Study Registration Dates

First Submitted

March 6, 2025

First Submitted That Met QC Criteria

March 6, 2025

First Posted (Actual)

March 12, 2025

Study Record Updates

Last Update Posted (Actual)

June 10, 2026

Last Update Submitted That Met QC Criteria

June 9, 2026

Last Verified

June 1, 2026

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

IPD Plan Description

Further studies may be shared but this stage of the research process is too earlier.

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.