The overall objective of this proposal is to develop a non-invasive, inexpensive and accurate device that detects VOCs in exhaled breath for lung cancer screening. Toward this goal, the team will design and fabricate a biophotonic platform consists of arrays of silicon micro-ring resonator sensors coated with polymers with different organic functionalities, in which each sensor is widely responsive to a variety of VOCs for the detection of lung cancer by means of breath testing. The team will identify signature VOCs as lung cancer biomarkers by comparison VOC contents between alveolar gas that directly sampled from the nodule or mass and exhaled breath using gas chromatography/ mass spectrometry.
The specific aims of this proposal are as followings:
Aim 1: To develop a biophotonic platform for the detection of VOCs
Aim 2: To achieve multiplex detection of VOCs with high sensitivity and specificity using a novel biophotonic device.
Aim 3: To evaluate the device as a lung cancer screening tool by testing both healthy and lung cancer breath samples
Přehled studie
Postavení
Podmínky
Intervence / Léčba
Detailní popis
Lung cancer is the leading cause of cancer deaths throughout the world and accounts for more than 1.2M new cases worldwide annually, making lung cancer one of the most serious public health problems in industrialized countries. Up to date there is no valid screening method for lung cancer. Thus it is often diagnosed at an advance stage when treatment is less effective, which consequantly leads to high mortality rate. However, with early diagnosis and treatment, the 5-year survival rate improves dramatically from 1% in stage 4, 20% in stage 3 to 70% in stage 1 disease. Therefore early diagnosis plays a pivotal role in improving survival for this otherwise uniformly fatal disease. In recently studies, it was found that some of the products of metabolism, called volatile organic comounds (VOCs), are carried in the breath and can serve as biomarkers. Cancer cells produce different types of VOCs than normal cells do. More importantly, these VOC markers can be found in exhaled breath for cancer stages 1 through 4.
Combining the strength of IME's in the biophotonics, the research groups at NUS in basic science and the NUH clinician's knowledge and expertise in lung cancer, this proposal is aiming to tackle the challenge of lung cancer screening by developing a non-invasive, inexpensive, and accurate sensor platform to detect VOCs in exhaled breath. The device will consists of arrays of silicon micro-ring resonator sensors coated with polymers with different organic functionalities, in which each sensor is widely responsive to a variety of VOCs. In this proposal, we plan to build a prototype device and test for the detection of VOCs in exhaled breath from healthy controls and lung cancer patients. The successful outcome of this proposal would have an immense impact on lung cancer management by enabling an early stage cancer screening.
Typ studie
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
-
Singapore, Singapur, 117685
- Institute of Microelectronics
-
Singapore, Singapur, 119074
- National University Hospital/ National University of Singapore
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- All patients aged above 21 years, capable of giving consent and suspected of lung cancer with radiological lung nodules and masses.
Exclusion Criteria:
- Patients with contra-indications to bronchoscopy and CT-TTNA that include active myocardial ischemia, uncorrected coagulopathy, severe respiratory distress, uncontrollable cough, and pregnancy will be excluded. Before females in the reproductive age are recruited, urine pregnancy test will be performed and confirmed negative.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Diagnostický
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
|---|
|
Identification of signature VOCs as ling cancer biomarkers by comparing VOC contents between alveolar gas from lung nodules and exhaled gas.
|
Spolupracovníci a vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Pyng Lee, MD, National University Hospital, Singapore
- Vrchní vyšetřovatel: Mi Kyoung Park, Ph.D, Institute of Microelectronics
Publikace a užitečné odkazy
Obecné publikace
- Peng G, Tisch U, Adams O, Hakim M, Shehada N, Broza YY, Billan S, Abdah-Bortnyak R, Kuten A, Haick H. Diagnosing lung cancer in exhaled breath using gold nanoparticles. Nat Nanotechnol. 2009 Oct;4(10):669-73. doi: 10.1038/nnano.2009.235. Epub 2009 Aug 30.
- Jemal A, Siegel R, Xu J, Ward E. Cancer statistics, 2010. CA Cancer J Clin. 2010 Sep-Oct;60(5):277-300. doi: 10.3322/caac.20073. Epub 2010 Jul 7. Erratum In: CA Cancer J Clin. 2011 Mar-Apr;61(2):133-4.
- Phillips M, Gleeson K, Hughes JM, Greenberg J, Cataneo RN, Baker L, McVay WP. Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study. Lancet. 1999 Jun 5;353(9168):1930-3. doi: 10.1016/S0140-6736(98)07552-7.
- International Early Lung Cancer Action Program Investigators; Henschke CI, Yankelevitz DF, Libby DM, Pasmantier MW, Smith JP, Miettinen OS. Survival of patients with stage I lung cancer detected on CT screening. N Engl J Med. 2006 Oct 26;355(17):1763-71. doi: 10.1056/NEJMoa060476. Erratum In: N Engl J Med. 2008 Apr 24;358(17):1875. N Engl J Med. 2008 Aug 21;359(8):877. N Engl J Med. 2008 Apr 24;358(17):1862.
- Phillips M, Altorki N, Austin JH, Cameron RB, Cataneo RN, Greenberg J, Kloss R, Maxfield RA, Munawar MI, Pass HI, Rashid A, Rom WN, Schmitt P. Prediction of lung cancer using volatile biomarkers in breath. Cancer Biomark. 2007;3(2):95-109. doi: 10.3233/cbm-2007-3204.
- Phillips M, Cataneo RN, Cummin AR, Gagliardi AJ, Gleeson K, Greenberg J, Maxfield RA, Rom WN. Detection of lung cancer with volatile markers in the breath. Chest. 2003 Jun;123(6):2115-23. doi: 10.1378/chest.123.6.2115.
- Sit AK, Sihoe AD, Suen WS, Cheng LC. Positron-emission tomography for lung cancer in a tuberculosis-endemic region. Asian Cardiovasc Thorac Ann. 2010 Feb;18(1):33-8. doi: 10.1177/0218492309352119.
- Mahadevia PJ, Fleisher LA, Frick KD, Eng J, Goodman SN, Powe NR. Lung cancer screening with helical computed tomography in older adult smokers: a decision and cost-effectiveness analysis. JAMA. 2003 Jan 15;289(3):313-22. doi: 10.1001/jama.289.3.313.
- Mazzone PJ. Analysis of volatile organic compounds in the exhaled breath for the diagnosis of lung cancer. J Thorac Oncol. 2008 Jul;3(7):774-80. doi: 10.1097/JTO.0b013e31817c7439.
- Filipiak W, Sponring A, Mikoviny T, Ager C, Schubert J, Miekisch W, Amann A, Troppmair J. Release of volatile organic compounds (VOCs) from the lung cancer cell line CALU-1 in vitro. Cancer Cell Int. 2008 Nov 24;8:17. doi: 10.1186/1475-2867-8-17.
- Di Natale C, Macagnano A, Martinelli E, Paolesse R, D'Arcangelo G, Roscioni C, Finazzi-Agro A, D'Amico A. Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors. Biosens Bioelectron. 2003 Sep;18(10):1209-18. doi: 10.1016/s0956-5663(03)00086-1.
- Mazzone PJ, Hammel J, Dweik R, Na J, Czich C, Laskowski D, Mekhail T. Diagnosis of lung cancer by the analysis of exhaled breath with a colorimetric sensor array. Thorax. 2007 Jul;62(7):565-8. doi: 10.1136/thx.2006.072892. Epub 2007 Feb 27.
- Peng G, Trock E, Haick H. Detecting simulated patterns of lung cancer biomarkers by random network of single-walled carbon nanotubes coated with nonpolymeric organic materials. Nano Lett. 2008 Nov;8(11):3631-5. doi: 10.1021/nl801577u. Epub 2008 Oct 8.
- Machado RF, Laskowski D, Deffenderfer O, Burch T, Zheng S, Mazzone PJ, Mekhail T, Jennings C, Stoller JK, Pyle J, Duncan J, Dweik RA, Erzurum SC. Detection of lung cancer by sensor array analyses of exhaled breath. Am J Respir Crit Care Med. 2005 Jun 1;171(11):1286-91. doi: 10.1164/rccm.200409-1184OC. Epub 2005 Mar 4.
- Carlborg CF, Gylfason KB, Kazmierczak A, Dortu F, Banuls Polo MJ, Maquieira Catala A, Kresbach GM, Sohlstrom H, Moh T, Vivien L, Popplewell J, Ronan G, Barrios CA, Stemme G, van der Wijngaart W. A packaged optical slot-waveguide ring resonator sensor array for multiplex label-free assays in labs-on-chips. Lab Chip. 2010 Feb 7;10(3):281-90. doi: 10.1039/b914183a. Epub 2009 Nov 12.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- SERC/1121480001
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Rakovina plic
-
Xiangya Hospital of Central South UniversityZatím nenabírámeNon Small Cell Lung | Metastázy v mozkuČína
-
Argentinian Intensive Care SocietyDokončenoDechová frekvence | End-exspiratory Lung Impedance | Zlomek tloušťky membrány | Exkurze brániceArgentina
-
Indiana UniversityRichard L. Roudebush VA Medical CenterDokončeno
-
Novartis PharmaceuticalsDokončenoNeuroendokrinní nádory | Advanced NET of GI Origin | Advanced NET of Lung OriginSpojené státy, Kolumbie, Itálie, Tchaj-wan, Spojené království, Belgie, Česko, Německo, Japonsko, Saudská arábie, Kanada, Holandsko, Španělsko, Korejská republika, Libanon, Rakousko, Čína, Řecko, Jižní Afrika, Thajsko, Maďarsko, Krocan a více
-
University Hospital, Clermont-FerrandCentral Hospital, Nancy, FranceDokončenoDítě, Pouze | Spontánní pneumotorax | Idiopatický pneumotorax | Bleb LungFrancie
-
University of LorraineDokončenoDítě, Pouze | Spontánní pneumotorax | Idiopatický pneumotorax | Bleb LungFrancie
-
Assiut UniversityZatím nenabírámeRakovina plic | Poranění plic | Bleb Lung
-
Jiangsu HengRui Medicine Co., Ltd.DokončenoNon Small Cell LungČína
-
SanofiRegeneron PharmaceuticalsDokončenoKarcinom | Non Small Cell LungSpojené státy, Francie, Kanada, Německo, Holandsko, Portugalsko, Španělsko, Švédsko, Čína, Bulharsko, Estonsko, Indie, Malajsie, Singapur, Tchaj-wan, Argentina, Rakousko, Finsko, Maďarsko, Itálie, Austrálie, Chile, Hongkong, Polsko, Řecko, ... a více
-
Taichung Veterans General HospitalDokončenoKardiotoxicita | Nádor plic bez malých buněk (MeSH termín: Carcinoma, Non-Small-Cell Lung) | Lékové nežádoucí účinky a nežádoucí reakce (MeSH termín) | Inhibitor tyrozinkinázy EGFRTchaj-wan
Klinické studie na Biophotonic platform for VOC detection
-
University of RochesterCharles River AnalyticsDokončenoKognitivní potíže související s rakovinou | Kognitivní porucha související s rakovinouSpojené státy