- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT02012673
A Safety and Feasibility Study of Re-treating Patients With Severe Emphysema With the RePneu LVRC System. (RECOIL)
The Safety and Feasibility of Re-treating Patients With Severe Emphysema With the RePneu LVRC System: a Pilot Study.
Rationale:
The combined data from 3 studies outside the Unites States investigating the Lung Volume Reduction Coil system (RePneu LVRC) showed statistically significant improvements in pulmonary function, exercise capacity and quality of life at both 6-Months and 12-Months post treatment. 24 months post treatment the improved pulmonary function and exercise capacity are slightly decreasing. Retreating the patient with the LVR coil system in other parts of the lung could potentially lead to new improvements in lung function, dyspnea, exercise capacity and quality of life and may reduce the rate of decline.
Objective:
To investigate the safety and feasibility of re-treating patients with severe Chronic Obstructive Pulmonary Disease (COPD) with the RePneu LVRC system.
Přehled studie
Postavení
Intervence / Léčba
Detailní popis
Rationale:
The combined data from 3 studies outside the Unites States investigating the Lung Volume Reduction Coil system (RePneu LVRC) showed statistically significant improvements in pulmonary function, exercise capacity and quality of life at both 6-Months and 12-Months post treatment. 24 months post treatment the improved pulmonary function and exercise capacity are slightly decreasing. Retreating the patient with the LVR coil system in other parts of the lung could potentially lead to new improvements in lung function, dyspnea, exercise capacity and quality of life and may reduce the rate of decline.
Objective:
To investigate the safety and feasibility of re-treating patients with severe Chronic Obstructive Pulmonary Disease (COPD) with the RePneu LVRC system.
Study design:
This study is a non randomized uncontrolled intervention.
Study population: Patients with severe emphysema who have previously been treated with the lung volume reduction coil system and significantly improved in lung function, exercise capacity or quality of life, 6 months after the treatment.
Intervention:
Patients will receive a lung volume reduction coil treatment by bronchoscopy.
Main study parameter:
The safety objective of this study is to identify the potential number and type of device-related and procedure-related adverse effects.
Secondary study parameters:
Lung function
- Change in RV, 6 months following treatment
- Change in RV/TLC ratio, 6 months following treatment
- Changes in FEV1 and FVC, 2 and 6 months following treatment
Quality of life
- Change in the SGRQ score, 2 and 6 months following treatment
- Change in the CCQ score, 2 and 6 months following treatment
Functional measures
- Change in the mMRC score, 2 and 6 months following treatment
- Change in the 6MWD, 2 and 6 months following treatment
Typ studie
Zápis (Aktuální)
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
-
Groningen, Holandsko
- University Medical Center Groningen
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dítě
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Treated with the RePneu LVRC system > 24 months ago.
- Six months after the first bilateral treatment with the RePneu LVRC system the patient had a significant improvement above the established minimal important difference (MID) of 6-minute walk distance (6MWD: 26 meter) or of forced expiratory volume in 1 second (FEV1: 100ml) or of St. Georges Respiratory Questionnaire total score (SGRQ: 4 points).
- Subject has marked dyspnea scoring ≥2 on mMRC scale of 0-4.
- Subject has stopped smoking for at least 6 months prior to entering the study.
- Subject read, understood and signed the Informed Consent form.
- Subject has completed a pulmonary rehabilitation program within 6 months prior to treatment and/or regularly performing maintenance respiratory rehabilitation if initial supervised therapy occurred more than 6 months prior to baseline testing.
- Subject has received Influenza vaccinations consistent with local recommendations and/or policy.
Exclusion Criteria:
- Subject has co-morbidities that may significantly reduce subject's ability to improve exercise capacity (e.g., severe arthritis, planned knee surgery) or baseline limitation on 6MWT is not due to dyspnea.
Subject has severe gas exchange abnormalities as defined by:
PaCO2 >8.0 kPa; PaO2 < 6.0 kPa (room air).
- Subject has a history of recurrent clinically significant respiratory infections, defined as 3 hospitalizations for respiratory infection during the year prior to enrollment.
- Subject has severe pulmonary hypertension defined by right ventricular systolic pressure >50 mm Hg via echocardiogram.
- Subject has an inability to walk >140 meters in 6 minutes.
- Subject has evidence of other severe disease (such as, but not limited to, lung cancer or renal failure), which in the judgment of the investigator may compromise survival of the subject for the duration of the study.
- Subject is pregnant or lactating, or plans to become pregnant within the study timeframe.
- Subject has an inability to tolerate bronchoscopy under moderate sedation or general anesthesia.
- Subject has clinically significant bronchiectasis.
- Subject has giant bullae >1/3 lung volume.
- Subject has had previous LVR surgery, lung transplantation or lobectomy.
- Subject has been involved in pulmonary drug or device studies within 30 days prior to this study.
- Subject is taking >20 mg prednisone (or equivalent dose of a similar steroid) daily.
- Subject requires high level chronic immunomodulatory therapy to treat a moderate to severe chronic inflammatory autoimmune disorder.
- Subject is on an antiplatelet (such as Plavix) or anticoagulant therapy (such as heparin or Coumadin) which cannot be stopped for 7 days prior to procedure.
- Subject has a sensitivity or allergy to Nickel.
- Subject has a known sensitivity to drugs required to perform bronchoscopy.
- Subject has any other disease, condition(s) or habit(s) that would interfere with completion of study and follow up assessments, would increase risks of bronchoscopy or assessments, or in the judgment of the investigator would potentially interfere.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: Bronchoscopic lung volume reduction
Bronchoscopic lung volume reduction with the RePneu Lung Volume Reduction Coil system
|
Bronchoscopic lung volume reduction with the RePneu Lung Volume Reduction Coil system.
The RePneu LVRC is an implantable device, delivered through a fiber-optic bronchoscope, designed specifically to treat patients suffering from emphysema.
The Coil is intended to compress the most damaged parenchyma and tension the surrounding tissue, which increases elastic recoil, reduces hyperinflation and redirects air to healthier portions of the lung for more effective ventilation.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Number and type of adverse effects as a measure of safety between baseline and 6 months follow up
Časové okno: Baseline - 6 month follow up
|
The safety objective of this study is to identify the potential number and type of device-related and procedure-related adverse effects.
|
Baseline - 6 month follow up
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Change from Baseline in Lung function at 2 months
Časové okno: Baseline vs 2 month follow up
|
-Changes in FEV1 and FVC, 2 months following treatment
|
Baseline vs 2 month follow up
|
|
Change from Baseline in Quality of life at 2 months
Časové okno: Baseline vs 2 month follow up
|
|
Baseline vs 2 month follow up
|
|
Change from Baseline in functional measures at 2 months
Časové okno: Baseline vs 2 month follow up
|
|
Baseline vs 2 month follow up
|
|
Change from Baseline in Lung function at 6 months
Časové okno: Baseline vs 6 month follow up
|
|
Baseline vs 6 month follow up
|
|
Change from Baseline in quality of life at 6 months
Časové okno: Baseline vs 6 month follow up
|
|
Baseline vs 6 month follow up
|
|
Change from Baseline in functional measures at 6 months
Časové okno: Baseline vs 6 month follow up
|
|
Baseline vs 6 month follow up
|
Spolupracovníci a vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Dirk-Jan Slebos, MD PhD, University Medical Center Groningen, Department of Pulmonary Diseases
Publikace a užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- RECOIL-study
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .