Effect of Three Side Hole Infusion Catheter on CT Image Quality Compared to a Standard Infusion Catheter
3. května 2018 aktualizováno: Joseph P Hasapes, The University of Texas Health Science Center, Houston
IV Contrast Administration: Effect of Three Side Hole Infusion Catheter on CT Image Quality, Infusion Pressure, and Infusion Rates, Compared to a Standard Infusion Catheter
The purpose of this research study is to compare two types of catheters used for infusing the contrast dye necessary for viewing internal organs during computed tomography (CT) scanning.
The standard catheter, which has one hole from which contrast dye enters veins, will be compared to the Becton Dickinson Nexiva Diffusics System catheter, which has three holes for diffusing dye into veins.
The purpose of this study is to determine which catheter type gives the best image.
Přehled studie
Postavení
Dokončeno
Detailní popis
This will be a prospective, randomized, controlled trial.
The catheter is already in use at our facilities.
After informed consent, patients will be randomly given the standard or new catheter in our practice.
Envelopes with the random assignment will be available to the individuals consenting patients.
Randomization generally ensures that study groups are similar on average.
As age, sex, and weight impact image quality, we will collect data on these factors in case randomization results in an imbalance.
This will allow for control of these factors in analysis of the data.
Data will be collected from CT abdomen pelvis examinations within a 6 month-1 year period in 2016 - 2017.
Our primary outcome is image quality, measured as tissue density and distribution of contrast within the liver, spleen, aorta and IVC.
Our secondary outcomes include Peak Contrast Infusion Pressure and Injection Flow Rate.
Possible adverse events for use of any type of catheter include contrast infiltration into the subcutaneous tissues which is a minor limited event.
All infiltrations will be recorded as part of the permanent medical record, documented in the chart, and the referring physician notified.
The patient will be assessed by a physician immediately and referred to the ED if necessary for further evaluation.
Current technology utilizes Power injector equipment which alerts the technologist to the pressure being achieved.
If the injection pressure exceeds 325 psi the Power injector automatically shuts off.
Typ studie
Intervenční
Zápis (Aktuální)
61
Fáze
- Nelze použít
Kontakty a umístění
Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.
Studijní místa
-
-
Texas
-
Houston, Texas, Spojené státy, 77030
- The University of Texas Health Science Center at Houston
-
-
Kritéria účasti
Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.
Kritéria způsobilosti
Věk způsobilý ke studiu
18 let a starší (Dospělý, Starší dospělý)
Přijímá zdravé dobrovolníky
Ne
Pohlaví způsobilá ke studiu
Všechno
Popis
Inclusion Criteria:
- Patients undergoing contrast enhanced CT abdomen pelvis examinations at Lyndon B. Johnson General Hospital in Texas
- Patients whose access point is the antecubital fossa
- Patients receiving 20 or 22 gauge catheters for their CT exam
- Patients scanned on two 64 slice CT scanners at the same hospital
Exclusion Criteria:
- patients whose access point is other than antecubital fossa
Studijní plán
Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.
Jak je studie koncipována?
Detaily designu
- Primární účel: Diagnostický
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Trojnásobný
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: Becton Dickinson Nexiva Diffusics System
Intervention with the new Becton Dickinson Nexiva Diffusics System will be evaluated to see if it will improve image quality compared to the standard catheter.
|
Becton Dickinson Nexiva Diffusics System will be used to inject IV contrast and will be compared to a single hole catheter to see if it improves image quality in the main vessels in the abdomen and pelvis because of its novel design.
|
|
Aktivní komparátor: Standard intravenous catheter
Standard catheter with one hole at the tip will be compared to novel 3 hole Becton Dickinson Nexiva Diffusics System to see which catheter provides the best image quality.
|
Standard catheter with one hole at the tip will be compared to a novel 3 hole catheter to see which catheter provides the best image quality.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Image Quality as Assessed by Ratio of Tissue Density of Main Portal Vein (MPV) to the Aorta
Časové okno: at the time of CT scanning
|
The ratio of tissue density measured in the main portal vein (MPV) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality.
Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
|
at the time of CT scanning
|
|
Image Quality as Assessed by Ratio of Tissue Density of Spleen to the Aorta
Časové okno: at the time of CT scanning
|
The ratio of tissue density measured in the spleen to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality.
Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
|
at the time of CT scanning
|
|
Image Quality as Assessed by Ratio of Tissue Density of Inferior Vena Cava (IVC) to the Aorta
Časové okno: at the time of CT scanning
|
The ratio of tissue density measured in the inferior vena cava (IVC) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality.
Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
|
at the time of CT scanning
|
|
Image Quality as Assessed by Rating Scale
Časové okno: at the time of CT scanning
|
Radiologists blinded to catheter type will review images and rate them on a scale of 1 to 10. 10 indicates a better outcome.
|
at the time of CT scanning
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Peak Contrast Infusion Pressure
Časové okno: at the time of CT scanning
|
The peak contrast infusion pressure is recorded in the electronic health record (EHR) during every CT examination preformed at the hospitals taking part in this study.
|
at the time of CT scanning
|
|
Injection Flow Rate
Časové okno: at the time of CT scanning
|
The injection flow rate is recorded in the electronic health record (EHR) during every CT examination preformed at the hospitals taking part in this study.
|
at the time of CT scanning
|
Spolupracovníci a vyšetřovatelé
Zde najdete lidi a organizace zapojené do této studie.
Vyšetřovatelé
- Vrchní vyšetřovatel: Joseph Hasapes, MD, The University of Texas Health Science Center, Houston
Termíny studijních záznamů
Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.
Hlavní termíny studia
Začátek studia (Aktuální)
1. října 2016
Primární dokončení (Aktuální)
1. listopadu 2016
Dokončení studie (Aktuální)
1. listopadu 2016
Termíny zápisu do studia
První předloženo
20. října 2016
První předloženo, které splnilo kritéria kontroly kvality
20. října 2016
První zveřejněno (Odhad)
24. října 2016
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
6. června 2018
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
3. května 2018
Naposledy ověřeno
1. května 2018
Více informací
Termíny související s touto studií
Další identifikační čísla studie
- HSC-MS15-0906
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .