- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT02943226
Effect of Three Side Hole Infusion Catheter on CT Image Quality Compared to a Standard Infusion Catheter
3. mai 2018 oppdatert av: Joseph P Hasapes, The University of Texas Health Science Center, Houston
IV Contrast Administration: Effect of Three Side Hole Infusion Catheter on CT Image Quality, Infusion Pressure, and Infusion Rates, Compared to a Standard Infusion Catheter
The purpose of this research study is to compare two types of catheters used for infusing the contrast dye necessary for viewing internal organs during computed tomography (CT) scanning.
The standard catheter, which has one hole from which contrast dye enters veins, will be compared to the Becton Dickinson Nexiva Diffusics System catheter, which has three holes for diffusing dye into veins.
The purpose of this study is to determine which catheter type gives the best image.
Studieoversikt
Status
Fullført
Intervensjon / Behandling
Detaljert beskrivelse
This will be a prospective, randomized, controlled trial.
The catheter is already in use at our facilities.
After informed consent, patients will be randomly given the standard or new catheter in our practice.
Envelopes with the random assignment will be available to the individuals consenting patients.
Randomization generally ensures that study groups are similar on average.
As age, sex, and weight impact image quality, we will collect data on these factors in case randomization results in an imbalance.
This will allow for control of these factors in analysis of the data.
Data will be collected from CT abdomen pelvis examinations within a 6 month-1 year period in 2016 - 2017.
Our primary outcome is image quality, measured as tissue density and distribution of contrast within the liver, spleen, aorta and IVC.
Our secondary outcomes include Peak Contrast Infusion Pressure and Injection Flow Rate.
Possible adverse events for use of any type of catheter include contrast infiltration into the subcutaneous tissues which is a minor limited event.
All infiltrations will be recorded as part of the permanent medical record, documented in the chart, and the referring physician notified.
The patient will be assessed by a physician immediately and referred to the ED if necessary for further evaluation.
Current technology utilizes Power injector equipment which alerts the technologist to the pressure being achieved.
If the injection pressure exceeds 325 psi the Power injector automatically shuts off.
Studietype
Intervensjonell
Registrering (Faktiske)
61
Fase
- Ikke aktuelt
Kontakter og plasseringer
Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.
Studiesteder
-
-
Texas
-
Houston, Texas, Forente stater, 77030
- The University of Texas Health Science Center at Houston
-
-
Deltakelseskriterier
Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
18 år og eldre (Voksen, Eldre voksen)
Tar imot friske frivillige
Nei
Kjønn som er kvalifisert for studier
Alle
Beskrivelse
Inclusion Criteria:
- Patients undergoing contrast enhanced CT abdomen pelvis examinations at Lyndon B. Johnson General Hospital in Texas
- Patients whose access point is the antecubital fossa
- Patients receiving 20 or 22 gauge catheters for their CT exam
- Patients scanned on two 64 slice CT scanners at the same hospital
Exclusion Criteria:
- patients whose access point is other than antecubital fossa
Studieplan
Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Diagnostisk
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Trippel
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: Becton Dickinson Nexiva Diffusics System
Intervention with the new Becton Dickinson Nexiva Diffusics System will be evaluated to see if it will improve image quality compared to the standard catheter.
|
Becton Dickinson Nexiva Diffusics System will be used to inject IV contrast and will be compared to a single hole catheter to see if it improves image quality in the main vessels in the abdomen and pelvis because of its novel design.
|
|
Aktiv komparator: Standard intravenous catheter
Standard catheter with one hole at the tip will be compared to novel 3 hole Becton Dickinson Nexiva Diffusics System to see which catheter provides the best image quality.
|
Standard catheter with one hole at the tip will be compared to a novel 3 hole catheter to see which catheter provides the best image quality.
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Image Quality as Assessed by Ratio of Tissue Density of Main Portal Vein (MPV) to the Aorta
Tidsramme: at the time of CT scanning
|
The ratio of tissue density measured in the main portal vein (MPV) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality.
Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
|
at the time of CT scanning
|
|
Image Quality as Assessed by Ratio of Tissue Density of Spleen to the Aorta
Tidsramme: at the time of CT scanning
|
The ratio of tissue density measured in the spleen to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality.
Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
|
at the time of CT scanning
|
|
Image Quality as Assessed by Ratio of Tissue Density of Inferior Vena Cava (IVC) to the Aorta
Tidsramme: at the time of CT scanning
|
The ratio of tissue density measured in the inferior vena cava (IVC) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality.
Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
|
at the time of CT scanning
|
|
Image Quality as Assessed by Rating Scale
Tidsramme: at the time of CT scanning
|
Radiologists blinded to catheter type will review images and rate them on a scale of 1 to 10. 10 indicates a better outcome.
|
at the time of CT scanning
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Peak Contrast Infusion Pressure
Tidsramme: at the time of CT scanning
|
The peak contrast infusion pressure is recorded in the electronic health record (EHR) during every CT examination preformed at the hospitals taking part in this study.
|
at the time of CT scanning
|
|
Injection Flow Rate
Tidsramme: at the time of CT scanning
|
The injection flow rate is recorded in the electronic health record (EHR) during every CT examination preformed at the hospitals taking part in this study.
|
at the time of CT scanning
|
Samarbeidspartnere og etterforskere
Det er her du vil finne personer og organisasjoner som er involvert i denne studien.
Etterforskere
- Hovedetterforsker: Joseph Hasapes, MD, The University of Texas Health Science Center, Houston
Studierekorddatoer
Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.
Studer hoveddatoer
Studiestart (Faktiske)
1. oktober 2016
Primær fullføring (Faktiske)
1. november 2016
Studiet fullført (Faktiske)
1. november 2016
Datoer for studieregistrering
Først innsendt
20. oktober 2016
Først innsendt som oppfylte QC-kriteriene
20. oktober 2016
Først lagt ut (Anslag)
24. oktober 2016
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
6. juni 2018
Siste oppdatering sendt inn som oppfylte QC-kriteriene
3. mai 2018
Sist bekreftet
1. mai 2018
Mer informasjon
Begreper knyttet til denne studien
Andre studie-ID-numre
- HSC-MS15-0906
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .