Effect of Three Side Hole Infusion Catheter on CT Image Quality Compared to a Standard Infusion Catheter

3 мая 2018 г. обновлено: Joseph P Hasapes, The University of Texas Health Science Center, Houston

IV Contrast Administration: Effect of Three Side Hole Infusion Catheter on CT Image Quality, Infusion Pressure, and Infusion Rates, Compared to a Standard Infusion Catheter

The purpose of this research study is to compare two types of catheters used for infusing the contrast dye necessary for viewing internal organs during computed tomography (CT) scanning. The standard catheter, which has one hole from which contrast dye enters veins, will be compared to the Becton Dickinson Nexiva Diffusics System catheter, which has three holes for diffusing dye into veins. The purpose of this study is to determine which catheter type gives the best image.

Обзор исследования

Подробное описание

This will be a prospective, randomized, controlled trial. The catheter is already in use at our facilities. After informed consent, patients will be randomly given the standard or new catheter in our practice. Envelopes with the random assignment will be available to the individuals consenting patients. Randomization generally ensures that study groups are similar on average. As age, sex, and weight impact image quality, we will collect data on these factors in case randomization results in an imbalance. This will allow for control of these factors in analysis of the data. Data will be collected from CT abdomen pelvis examinations within a 6 month-1 year period in 2016 - 2017. Our primary outcome is image quality, measured as tissue density and distribution of contrast within the liver, spleen, aorta and IVC. Our secondary outcomes include Peak Contrast Infusion Pressure and Injection Flow Rate. Possible adverse events for use of any type of catheter include contrast infiltration into the subcutaneous tissues which is a minor limited event. All infiltrations will be recorded as part of the permanent medical record, documented in the chart, and the referring physician notified. The patient will be assessed by a physician immediately and referred to the ED if necessary for further evaluation. Current technology utilizes Power injector equipment which alerts the technologist to the pressure being achieved. If the injection pressure exceeds 325 psi the Power injector automatically shuts off.

Тип исследования

Интервенционный

Регистрация (Действительный)

61

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

18 лет и старше (Взрослый, Пожилой взрослый)

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

  • Patients undergoing contrast enhanced CT abdomen pelvis examinations at Lyndon B. Johnson General Hospital in Texas
  • Patients whose access point is the antecubital fossa
  • Patients receiving 20 or 22 gauge catheters for their CT exam
  • Patients scanned on two 64 slice CT scanners at the same hospital

Exclusion Criteria:

  • patients whose access point is other than antecubital fossa

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Диагностика
  • Распределение: Рандомизированный
  • Интервенционная модель: Параллельное назначение
  • Маскировка: Тройной

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: Becton Dickinson Nexiva Diffusics System
Intervention with the new Becton Dickinson Nexiva Diffusics System will be evaluated to see if it will improve image quality compared to the standard catheter.
Becton Dickinson Nexiva Diffusics System will be used to inject IV contrast and will be compared to a single hole catheter to see if it improves image quality in the main vessels in the abdomen and pelvis because of its novel design.
Активный компаратор: Standard intravenous catheter
Standard catheter with one hole at the tip will be compared to novel 3 hole Becton Dickinson Nexiva Diffusics System to see which catheter provides the best image quality.
Standard catheter with one hole at the tip will be compared to a novel 3 hole catheter to see which catheter provides the best image quality.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Image Quality as Assessed by Ratio of Tissue Density of Main Portal Vein (MPV) to the Aorta
Временное ограничение: at the time of CT scanning
The ratio of tissue density measured in the main portal vein (MPV) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality. Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
at the time of CT scanning
Image Quality as Assessed by Ratio of Tissue Density of Spleen to the Aorta
Временное ограничение: at the time of CT scanning
The ratio of tissue density measured in the spleen to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality. Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
at the time of CT scanning
Image Quality as Assessed by Ratio of Tissue Density of Inferior Vena Cava (IVC) to the Aorta
Временное ограничение: at the time of CT scanning
The ratio of tissue density measured in the inferior vena cava (IVC) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality. Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
at the time of CT scanning
Image Quality as Assessed by Rating Scale
Временное ограничение: at the time of CT scanning
Radiologists blinded to catheter type will review images and rate them on a scale of 1 to 10. 10 indicates a better outcome.
at the time of CT scanning

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Peak Contrast Infusion Pressure
Временное ограничение: at the time of CT scanning
The peak contrast infusion pressure is recorded in the electronic health record (EHR) during every CT examination preformed at the hospitals taking part in this study.
at the time of CT scanning
Injection Flow Rate
Временное ограничение: at the time of CT scanning
The injection flow rate is recorded in the electronic health record (EHR) during every CT examination preformed at the hospitals taking part in this study.
at the time of CT scanning

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Следователи

  • Главный следователь: Joseph Hasapes, MD, The University of Texas Health Science Center, Houston

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

1 октября 2016 г.

Первичное завершение (Действительный)

1 ноября 2016 г.

Завершение исследования (Действительный)

1 ноября 2016 г.

Даты регистрации исследования

Первый отправленный

20 октября 2016 г.

Впервые представлено, что соответствует критериям контроля качества

20 октября 2016 г.

Первый опубликованный (Оценивать)

24 октября 2016 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

6 июня 2018 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

3 мая 2018 г.

Последняя проверка

1 мая 2018 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • HSC-MS15-0906

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .