Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Wunda Chair vs Mat Pilates: Balance Effects

15. června 2026 aktualizováno: Berivan Beril Kılıç, Biruni University

Comparison of the Acute Effects of Wunda Chair Pilates and Mat-Based Pilates Exercises on Balance in Healthy Women

The goal of this study is to compare the acute effects of Wunda Chair Pilates and mat-based Pilates exercises on balance performance in healthy adult women. It will also examine which type of Pilates exercise provides a more immediate improvement in balance. The main questions it aims to answer are:

Do Wunda Chair Pilates exercises lead to greater improvements in balance compared to mat-based Pilates after a single session? Are there differences between the two exercise approaches in terms of static balance, dynamic balance, and functional mobility?

Researchers will compare Wunda Chair Pilates with mat-based Pilates to determine which method is more effective in enhancing acute balance performance.

Participants will:

Be randomly assigned to either a Wunda Chair Pilates group or a mat-based Pilates group Perform a single 45-minute exercise session according to their assigned group Complete balance assessments (Single Leg Stance Test, Timed Up and Go Test, and Y-Balance Test) before and immediately after the exercise session

Přehled studie

Typ studie

Intervenční

Zápis (Aktuální)

40

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Istanbul
      • Istanbul, Istanbul, Turecko (Türkiye), 34103
        • Biruni University

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý

Přijímá zdravé dobrovolníky

Ano

Popis

Inclusion Criteria:

  • Being a woman aged 18-45 years
  • Having regularly practiced Pilates within the last 3 months
  • Having sufficient cognitive ability to understand and follow the study protocol
  • Having adequate physical capacity to safely perform the assessments and exercises

Exclusion Criteria:

  • History of severe trauma, surgery, or fracture involving the lower extremities, spine, or pelvis within the past 6 months
  • Presence of neurological disorders (e.g., vestibular disorders affecting balance, multiple sclerosis, Parkinson's disease, etc.)
  • History of vestibular system disorders or vertigo
  • Rheumatologic or inflammatory diseases affecting the lower extremities or spine
  • Systemic diseases that may affect balance or muscle performance (e.g., uncontrolled diabetes, severe cardiovascular disease, etc.)
  • Pregnancy or having given birth within the last 6 months
  • Acute musculoskeletal injury causing pain or functional limitation during exercise
  • Inability to complete the tests on the study day due to acute pain, fatigue, or discomfort

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Prevence
  • Přidělení: Randomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Aktivní komparátor: Wunda Chair Pilates
Participants in the Chair exercise group will perform an instrument-based Pilates program designed to improve balance and core stability. The exercises will be structured as 1 set of 12 repetitions and will include controlled movements against spring resistance, as well as positions involving loading on a narrow base of support. The exercise session is expected to last approximately 35 minutes.
Aktivní komparátor: Mat Based Pilates
Mat Pilates exercises are designed to improve balance control, core stability, and lower extremity muscle coordination. The program consists of static and dynamic balance exercises performed on the mat, with emphasis on maintaining proper postural alignment and core activation throughout the exercises. A BOSU device will be used in some of the exercises.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Dynamic Balance
Časové okno: pre-invention and immediatelety after invention
The Y-Balance Test is a reliable and valid method for assessing dynamic balance and will be used in this study. The YBT requires participants to maintain single-leg stance while reaching in three directions with the other leg: anterior, posterolateral, and posteromedial. The composite score is calculated by normalizing the sum of reach distances to lower limb length. Leg length will be measured from the anterior superior iliac spine to the medial malleolus using a tape measure. The YBT is widely used in the literature as a scientifically validated and reliable protocol for assessing dynamic balance capacity. Each limb will be tested three times, and the average value will be recorded. A 1-minute rest period will be provided between trials.
pre-invention and immediatelety after invention
Static Balance
Časové okno: pre-intervention and immediately after intevention
The Single Leg Stance Test is a simple and reliable method used to assess static balance performance. During the test, participants stand on one leg with eyes open, and the time until loss of balance is recorded in seconds. Performance is evaluated based on the maximum time the position can be maintained. Measurements will be performed three times for each lower extremity, and the average value will be recorded. The literature reports that this test has high reliability in healthy individuals and is a valid measure for static balance assessment.
pre-intervention and immediately after intevention
Functional Mobility and Balance
Časové okno: pre-intervention and immediately after intervention
The Timed Up and Go Test is a widely used clinical performance test designed to assess functional mobility, balance, walking speed, and dynamic postural control. It is a quick and commonly preferred assessment tool in clinical practice. The test includes functional movements required in daily life activities, such as sitting, standing up, walking, turning, and sitting down again. The Timed Up and Go Test demonstrates high test-retest reliability (ICC = 0.87-0.99) across different age groups and in individuals with musculoskeletal conditions. It has also been reported to show strong correlations with other measures of functional balance and gait performance, and it is considered a valid and reliable assessment tool in both clinical and research settings.
pre-intervention and immediately after intervention

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Publikace a užitečné odkazy

Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.

Obecné publikace

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

4. května 2026

Primární dokončení (Aktuální)

20. května 2026

Dokončení studie (Aktuální)

5. června 2026

Termíny zápisu do studia

První předloženo

29. dubna 2026

První předloženo, které splnilo kritéria kontroly kvality

8. května 2026

První zveřejněno (Aktuální)

13. května 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

16. června 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

15. června 2026

Naposledy ověřeno

1. května 2026

Více informací

Termíny související s touto studií

Klíčová slova

Další identifikační čísla studie

  • 10

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit