- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT07839923
Prospective Evaluation of iCam-OCT
This is a prospective, non-significant-risk clinical study sponsored by Siloam Vision, Inc. to evaluate whether ophthalmologists can assess retinopathy of prematurity (ROP) using images from the iCam-OCT device as effectively as with the current standard, binocular indirect ophthalmoscopy (BIO). Results will support an FDA 510(k) submission. A separate follow-up study (undilated OCT imaging, with dilation only before the BIO exam) is planned once this study completes.
Device. The iCam-OCT is a handheld, swept-source OCT (SS-OCT) system operating at 1040nm and 400kHz, with 7-micron depth resolution and a 12mm scan depth. It captures an ultra-widefield (197°) field of view - the widest reported for OCT - in a contact-based, non-mydriatic mode, with scans under one second and a full bilateral exam averaging 1-2 minutes. It's designed for supine imaging of infants/small children who can't use conventional tabletop OCT. It's a Class 1 laser product conforming to IEC 60601-1, IEC 60601-1-2, IEC 60825-1, and ANSI Z80.36-2021. Over a dozen prior publications using earlier iCam-OCT prototypes (500+ patients, 1700+ imaging sessions) reported no adverse events and found the images clinically useful for ROP staging, zone assessment, and detection of related pathologies.
Sites and population. Two sites: Oregon Health & Science University (Doernbecher NICU) and Children's Hospital Colorado Anschutz. Both sites are new to the device and unaffiliated with the sponsor. Enrollment target is a minimum of 40 premature infants meeting AAP ROP-screening criteria (birth weight <1500g or gestational age ≤30 weeks; or birth weight 1500-2000g or gestational age >30 weeks if deemed at-risk). At least 30 infants must have ROP (stage 1 or worse in any zone) and at least 10 without ROP, with at least 20 subjects per site. Main exclusions are inability to obtain parental consent or clinical instability precluding research imaging.
Study design. After informed consent, each infant undergoes both a BIO exam (by an independent, ROP-experienced ophthalmologist unaffiliated with the sponsor) and iCam-OCT imaging, in randomized order, following pupil dilation per routine care. Imaging is performed by a trained/certified operator (ophthalmologist, nurse, technician, or coordinator) using a standardized protocol with up to six suggested scan views (posterior, temporal, nasal, temporal/nasal ora serrata, posterior HD). Anonymized OCT images are then graded independently by three masked, ROP-experienced ophthalmologists for image quality (0-3 scale) and clinical utility (usefulness for confirming normal structures or detecting pathology), and separately for ROP zone/stage/plus disease, without knowledge of the BIO findings.
Endpoints and performance goals.
Primary: percent of OCT image sets graded acceptable (score ≥2) for both quality and clinical utility - goal ≥85%.
Secondary: sensitivity/specificity of OCT-based ROP detection vs. BIO (goals >90% sensitivity, >70% specificity); documentation/visualization of full retinal vascularization to the ora serrata (same goals); and documentation of the vascular/avascular border in eyes with incomplete vascularization (same goals).
Safety: tracking of systemic AEs (nurse-initiated pauses), ocular AEs (corneal abrasion, conjunctival irritation, infection, need for topical medication), and any other AEs.
Discordant cases - infants classified "no ROP" by BIO but flagged as stage 1+ by OCT (potential false positives relative to the BIO gold standard) - get extra scrutiny: a coordinator reviews subsequent hospital records for later-diagnosed ROP, and all three graders reconvene to reach consensus on whether the OCT findings represent true early-stage ROP that BIO missed, versus immature retina with a defined vascular border. Clinical management throughout the study is driven by BIO only, not by OCT findings.
Statistics. The eye is the unit of analysis; each eye is graded independently by all three masked graders, and sensitivity/specificity are computed per grader and averaged. Sample size (n=30 for the ROP-positive group) was powered via a non-inferiority test assuming 85% BIO sensitivity (from a cited 2018 Biten et al. study), a 5% non-inferiority margin, and one-sided alpha of 0.05, yielding ~80% power. Supportive analyses include per-grader McNemar's tests for OCT/BIO discordance and non-inferiority testing of OCT sensitivity against the fixed 85% literature benchmark (not a within-study BIO comparison).
Safety monitoring. Risks are characterized as low (corneal abrasion, subconjunctival hemorrhage, infection - similar to standard contact ROP exams) plus general risks of apnea/bradycardia inherent to examining fragile premature infants. Dr. Benjamin Young serves as the independent safety monitor overseeing adverse event review; AEs/SAEs must be reported to the IRB within 5 days.
Přehled studie
Postavení
Podmínky
Intervence / Léčba
Typ studie
Zápis (Aktuální)
Kontakty a umístění
Studijní místa
-
-
Oregon
-
Portland, Oregon, Spojené státy, 97239
- OHSU
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
The study population is premature infants indicated for ROP screening - approximately 40 such infants will be enrolled in total, matching AAP screening guidelines (birth weight <1500g or gestational age ≤30 weeks; or birth weight 1500-2000g or gestational age >30 weeks if judged at-risk by the attending pediatrician or neonatologist).
Popis
Inclusion Criteria:The patient must be an infant matching American Academy of Pediatrics (AAP) screening criteria for ROP evaluation, defined as one of the following:
- A birth weight of <1500g, or a gestational age of ≤30 weeks; or
- A birth weight between 1500-2000g, or
- A gestational age of >30 weeks, in infants who are believed to be at risk by their attending pediatrician or neonatologist.
Exclusion Criteria:
- Inability to obtain informed consent from the parent or guardian or
- The infant is deemed clinically unstable for research imaging by the neonatology team.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Observační modely: COHORT
- Časové perspektivy: PROSPECTIVE
Kohorty a intervence
Skupina / kohorta |
Intervence / Léčba |
|---|---|
|
Patient cohort
The study participants are premature infants who meet the American Academy of Pediatrics (AAP) screening criteria for ROP evaluation. Specifically, eligible infants must have either a birth weight under 1500g or a gestational age of 30 weeks or less, or, alternatively, a birth weight between 1500-2000g or a gestational age over 30 weeks if their attending pediatrician or neonatologist believes they're at risk for ROP. |
enrolled infant undergoes both a BIO exam and iCam-OCT imaging (order randomized) during the same dilated eye exam |
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Clinical Quality
Časové okno: study visit - day 1
|
The primary outcome measure is the clinical quality and utility of iCam-OCT images, as judged by three independent, masked, ROP-experienced ophthalmologist graders. |
study visit - day 1
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Presence or absence of ROP
Časové okno: study visit - day 1
|
Agreement between OCT image grading and BIO exam findings on whether ROP is present, defined as stage 1 or worse in any zone, with or without pre-plus or plus disease. Measured as sensitivity (target >90%) and specificity (target >70%), with BIO as the reference standard. |
study visit - day 1
|
Další výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Full vascularization documentation
Časové okno: study visit - day 1
|
In eyes that BIO determines to be fully vascularized, whether OCT can similarly document full retinal vascularization - specifically, visualization out to zone III and within two disc diameters of the ora serrata. Measured as sensitivity (target >90%) and specificity (target >70%); this assessment requires visualization of the ora serrata on the OCT images. |
study visit - day 1
|
|
Vascular/avascular border documentation
Časové okno: study visit - day 1
|
In eyes with incomplete retinal vascularization (areas of avascular retina) per BIO, whether OCT can document the vascular/avascular border. Again measured as sensitivity (target >90%) and specificity (target >70%). Visibility of the ora serrata is not required for this particular assessment. |
study visit - day 1
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Studijní židle: John P Campbell, MD, Siloam Vision
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
- SVCT-CIP-005 V04
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
There is a plan to make IPD and related data dictionaries available.
Typ podpůrných informací pro sdílení IPD
- PROTOKOL STUDY
- MÍZA
- ICF
- CSR
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
produkt vyrobený a vyvážený z USA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .