A Simple Method to Determine the Reflex Latency During WBV
A Simple Method to Determine the Reflex Latency During Whole Body Vibration
The purpose of this study was to examine the validity of the measurement method based on observation of vibration stimulation-MUAP (motor unit action potential) (1 to 1) matching that helps to measure human WBV-induced muscular reflex latency and to compare these results with the latency determination obtained using the classical methods. The investigators' principle hypothesis is that the simple method is capable of determining the WBV induced reflex response latency as reliably as the complex methods described earlier.
To achieve this goal, the investigators have averaged the electrical responses of the soleus muscle (sEMG and multi motor unit (MMU) potential) against the vertical force data obtained during all the six vibration frequencies tested in this study. The investigators have then combined all the averaged EMG data belonging to six different vibration frequencies to generate the 'cumulative averaged' sEMG and MMU for each subject. The investigators have also obtained the standard error for the cumulative averaged records which indicated the WBV-induced muscular reflex (WBV-IMR) latency.
Studieoversigt
Status
Betingelser
Intervention / Behandling
Detaljeret beskrivelse
Subjects Five healthy volunteers will be participated in the study.
Procedures During WBV, the subjects will be asked to stand upright on a vibration platform (PowerPlate Pro5, London, United Kingdom). Their hips and knees will be in a neutral position. Subjects will be barefooted, and no sponge or foam will be placed between the vibration platform and their feet (Figure 1). The whole plate oscillates with a linear movement upward and downward. Vibration amplitude is 2.2 mm. WBV frequencies will be varied randomly to cover the following six frequencies: 25, 30, 35, 40,45 and 50 Hz. Each frequency lasts for 60 seconds and there will be a 15 seconds rest in between different frequencies.
A load sensor (FC2331-0000-2000L Compression Load Sensor, France) will be fixed on the WBV platform in order to be able to determine induced muscular response latency. Subjects will be positioned on the WBV platform such that their right heel will be placed on the load sensor.
Recordings MMUs, surface EMG (sEMG) and force recordings will be simultaneously done using the Powerlab data acquisition system (ADInstruments, Oxford, United Kingdom). A sampling frequency of 40 kiloHertz (kHz) will be used. Data will be analyzed offline using the MATLAB (R2012a 7.14.0.739).
In order to record sEMG, Ag/AgCl electrodes [KENDALL ® Arbo] with a disc radius of 10 mm will be placed 20 mm apart on the right soleus muscle belly, on shaved skin cleaned with alcohol. The ground electrode will be placed on the lateral malleolus.
To record MMU activity, a pair of Teflon® insulated silver wires (75 µm in core diameter) will be used. About 3 mm of the tips of the silver wires will be stripped of their Teflon ® coating in order to be able to record the activity of several motor units. The pair of wires will be inserted into the right soleus muscle with a 25 G needle. Needle will be immediately withdrawn leaving the fish-hooked wires in the muscle. A lip-clip electrode will be used as the ground electrode.
All cables will be carefully taped to the skin to minimize mechanical artifacts.
The subjects will be instructed to relax their muscles throughout the recordings and were trained using EMG feedback to this end. WBV may impair the sense of balance and muscles may be activated to restore balance. To overcome this issue, the subjects will be familiarized with WBV with a 15 s session of WBV, the subjects will be asked to use the handles of the WBV device to secure their balance and the base of support (distance between the heels) will be adjusted as wide. The distance between the heels usually will be about 25 cm.
Filtering and Rectification regimens All force sensor recordings will be 5 Hz high-pass filtered. All sEMG recordings will be 80 - 500 Hz band-pass filtered (Butterworth 1st order) and full-wave rectified to overcome movement artifacts. All MMU recordings will be 100-5000 Hz band-pass filtered (Butterworth 1st order) and full-wave rectified.
WBV - induced muscular reflex (WBV-IMR) latency
In a previous study, right soleus muscle sEMG measurement and force sensor measurement that is placed under right heel during WBV were taken synchronously and it was found that vibration stimulation and MUAPs would be matched 1 to 1. In this study that is based on the previous observation, it is predicted that it is possible to calculate latency by using averaging method.
All MMU and sEMG data will be analyzed by applying respectively filtering, rectification and differentiation with MATLAB (R2012a 7.14.0.739). Data analysis will be performed in two stages:
- Detection of the moment of mechanical stimulation threshold (Force Sensor Data Averaging): Force sensor data will be averaged by using Spike triggered averaging (STA) method. For this, 50 seconds of constant time intervals of preset vibration frequency in a WBV set will be used. All the positive peaks in both MMU and sEMG traces will be marked. For all the positive peaks, the force sensor trace will be segmented covering 75 ms previous positive peak. After, cumulative average of these 6 vibration sets will be averaged. The standard error on the cumulative averaged force records will be calculated. The lowest point of standard error on force sensor averaging graphic will be considered as the starting point of mechanical stimulation that triggers the muscle response.
- Determination of the MUAP onset: EMG data averaging method and manual method (vibration stimulus and MUAP coupling) will be used.
Undersøgelsestype
Tilmelding (Faktiske)
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
-
İstanbul, Kalkun
- Bağcılar Training & Research Hospital
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- Young adult (20-45 yrs)
- Healthy
- Right handed
Exclusion Criteria:
- Any health problems
- Left handed
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Grundvidenskab
- Tildeling: N/A
- Interventionel model: Enkelt gruppeopgave
- Maskning: Ingen (Åben etiket)
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: Whole-body vibration
A new method for muscle reflex latency measurement
|
High amplitude whole-body vibration
Andre navne:
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Latency measurement method
Tidsramme: 1 day
|
1 day
|
Samarbejdspartnere og efterforskere
Efterforskere
- Studiestol: ILHAN KARACAN, MD, Bagcilar Training & Research Hospital
Datoer for undersøgelser
Studer store datoer
Studiestart
Primær færdiggørelse (Faktiske)
Studieafslutning (Faktiske)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Skøn)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
- BEAH FTR-9
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
produkt fremstillet i og eksporteret fra U.S.A.
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Latency Period (Psychology)
-
University of ManitobaIkke rekrutterer endnu
-
University of ArizonaNational Heart, Lung, and Blood Institute (NHLBI)Ikke rekrutterer endnu
-
Nutrition Institute, SloveniaValens Int. d.o.o., Slovenija; Faculty of Pharmacy, University of Ljubljana... og andre samarbejdspartnereRekrutteringSøvnkvalitet | Sleep Onset LatencySlovenien
-
Pamukkale UniversityRekrutteringAmning Self-Efficacy Attitude til sundhed Postpartum Period PrimiparityKalkun
-
The First Affiliated Hospital of Shanxi Medical...Shanxi Medical UniversityAfsluttetSøvnkvalitet | Søvnvarighed | Sleep Onset LatencyKina
-
Institute of Nutrition, Slovenia (Nutris)Valens Int. d.o.o., Slovenija; Faculty of Pharmacy, University of Ljubljana... og andre samarbejdspartnereIkke rekrutterer endnuSøvnkvalitet | Sleep Onset LatencySlovenien
-
Sheba Medical CenterRekrutteringFor tidlig fødsel | Graviditetskomplikationer, smitsom | Præmaturitet | Antibiotisk profylakse | Neonatale sygdomme og abnormiteter | Latency periodeIsrael
-
Universidade Federal do Rio de JaneiroAfsluttetSmerter, postoperativ | Motorisk aktivitet | Fascikulær blok | Latency periode
Kliniske forsøg med whole-body vibration
-
University of MiamiHyperVibe Pty LtdTrukket tilbageKropssammensætning, gavnlig | Fysisk konditionForenede Stater
-
Klinikum der Universität KölnUkendtÆndringer i seks minutters gåafstand, maksimal iltoptagelse, livskvalitetTyskland
-
Trakya UniversityAfsluttetCerebral parese (CP)Tyrkiet (Türkiye)
-
Cairo UniversityRekruttering
-
Gamze BULUTAtaturk UniversityIkke rekrutterer endnuPostoperativ smerte | Angst | Thorakal drainage
-
Universitat Internacional de CatalunyaIkke rekrutterer endnuAt vurdere effektiviteten af en fokal vibrationsbehandling på squat-kraft og -hastighed hos atleter, der udfører squats
-
Burdur Mehmet Akif Ersoy UniversityAfsluttetSmertebehandling | Nyfødt | Amning | Nålestikskader | Sår, gennemtrængende | VibrationKalkun
-
King Saud UniversityAfsluttet
-
Bitlis Eren UniversityAfsluttet
-
Bitlis Eren UniversityIkke rekrutterer endnu