A Simple Method to Determine the Reflex Latency During WBV
A Simple Method to Determine the Reflex Latency During Whole Body Vibration
The purpose of this study was to examine the validity of the measurement method based on observation of vibration stimulation-MUAP (motor unit action potential) (1 to 1) matching that helps to measure human WBV-induced muscular reflex latency and to compare these results with the latency determination obtained using the classical methods. The investigators' principle hypothesis is that the simple method is capable of determining the WBV induced reflex response latency as reliably as the complex methods described earlier.
To achieve this goal, the investigators have averaged the electrical responses of the soleus muscle (sEMG and multi motor unit (MMU) potential) against the vertical force data obtained during all the six vibration frequencies tested in this study. The investigators have then combined all the averaged EMG data belonging to six different vibration frequencies to generate the 'cumulative averaged' sEMG and MMU for each subject. The investigators have also obtained the standard error for the cumulative averaged records which indicated the WBV-induced muscular reflex (WBV-IMR) latency.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Subjects Five healthy volunteers will be participated in the study.
Procedures During WBV, the subjects will be asked to stand upright on a vibration platform (PowerPlate Pro5, London, United Kingdom). Their hips and knees will be in a neutral position. Subjects will be barefooted, and no sponge or foam will be placed between the vibration platform and their feet (Figure 1). The whole plate oscillates with a linear movement upward and downward. Vibration amplitude is 2.2 mm. WBV frequencies will be varied randomly to cover the following six frequencies: 25, 30, 35, 40,45 and 50 Hz. Each frequency lasts for 60 seconds and there will be a 15 seconds rest in between different frequencies.
A load sensor (FC2331-0000-2000L Compression Load Sensor, France) will be fixed on the WBV platform in order to be able to determine induced muscular response latency. Subjects will be positioned on the WBV platform such that their right heel will be placed on the load sensor.
Recordings MMUs, surface EMG (sEMG) and force recordings will be simultaneously done using the Powerlab data acquisition system (ADInstruments, Oxford, United Kingdom). A sampling frequency of 40 kiloHertz (kHz) will be used. Data will be analyzed offline using the MATLAB (R2012a 7.14.0.739).
In order to record sEMG, Ag/AgCl electrodes [KENDALL ® Arbo] with a disc radius of 10 mm will be placed 20 mm apart on the right soleus muscle belly, on shaved skin cleaned with alcohol. The ground electrode will be placed on the lateral malleolus.
To record MMU activity, a pair of Teflon® insulated silver wires (75 µm in core diameter) will be used. About 3 mm of the tips of the silver wires will be stripped of their Teflon ® coating in order to be able to record the activity of several motor units. The pair of wires will be inserted into the right soleus muscle with a 25 G needle. Needle will be immediately withdrawn leaving the fish-hooked wires in the muscle. A lip-clip electrode will be used as the ground electrode.
All cables will be carefully taped to the skin to minimize mechanical artifacts.
The subjects will be instructed to relax their muscles throughout the recordings and were trained using EMG feedback to this end. WBV may impair the sense of balance and muscles may be activated to restore balance. To overcome this issue, the subjects will be familiarized with WBV with a 15 s session of WBV, the subjects will be asked to use the handles of the WBV device to secure their balance and the base of support (distance between the heels) will be adjusted as wide. The distance between the heels usually will be about 25 cm.
Filtering and Rectification regimens All force sensor recordings will be 5 Hz high-pass filtered. All sEMG recordings will be 80 - 500 Hz band-pass filtered (Butterworth 1st order) and full-wave rectified to overcome movement artifacts. All MMU recordings will be 100-5000 Hz band-pass filtered (Butterworth 1st order) and full-wave rectified.
WBV - induced muscular reflex (WBV-IMR) latency
In a previous study, right soleus muscle sEMG measurement and force sensor measurement that is placed under right heel during WBV were taken synchronously and it was found that vibration stimulation and MUAPs would be matched 1 to 1. In this study that is based on the previous observation, it is predicted that it is possible to calculate latency by using averaging method.
All MMU and sEMG data will be analyzed by applying respectively filtering, rectification and differentiation with MATLAB (R2012a 7.14.0.739). Data analysis will be performed in two stages:
- Detection of the moment of mechanical stimulation threshold (Force Sensor Data Averaging): Force sensor data will be averaged by using Spike triggered averaging (STA) method. For this, 50 seconds of constant time intervals of preset vibration frequency in a WBV set will be used. All the positive peaks in both MMU and sEMG traces will be marked. For all the positive peaks, the force sensor trace will be segmented covering 75 ms previous positive peak. After, cumulative average of these 6 vibration sets will be averaged. The standard error on the cumulative averaged force records will be calculated. The lowest point of standard error on force sensor averaging graphic will be considered as the starting point of mechanical stimulation that triggers the muscle response.
- Determination of the MUAP onset: EMG data averaging method and manual method (vibration stimulus and MUAP coupling) will be used.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
İstanbul, Tacchino
- Bağcılar Training & Research Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Young adult (20-45 yrs)
- Healthy
- Right handed
Exclusion Criteria:
- Any health problems
- Left handed
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Scienza basilare
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Whole-body vibration
A new method for muscle reflex latency measurement
|
High amplitude whole-body vibration
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Latency measurement method
Lasso di tempo: 1 day
|
1 day
|
Collaboratori e investigatori
Investigatori
- Cattedra di studio: ILHAN KARACAN, MD, Bagcilar Training & Research Hospital
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- BEAH FTR-9
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su whole-body vibration
-
University of MiamiHyperVibe Pty LtdRitiratoComposizione corporea, benefica | Idoneità fisicaStati Uniti
-
West Virginia UniversityCompletatoQualità del sonnoStati Uniti
-
Charles (Chuck) RaisonRitiratoFibromialgiaStati Uniti
-
Charite University, Berlin, Germanymiha bodytec GmbHSconosciuto
-
Balgrist University HospitalIndustry (Schülke & Mayr AG, Switzerland and Germany)CompletatoChirurgia elettiva | Alto rischio | Prevenzione delle infezioni del sito chirurgico | Esperimento casuale controllatoSvizzera
-
War Related Illness and Injury Study CenterCompletatoPreoccupazioni Sanitarie ComplesseStati Uniti
-
Lawson Health Research InstituteOntario Institute for Cancer ResearchCompletatoMetastasi al cervello del cancro primarioCanada
-
VA Office of Research and DevelopmentAttivo, non reclutanteAbitazione | Utilizzo del servizio di terapia intensiva | Stato di salute mentale | Stato di salute fisicaStati Uniti
-
Good Samaritan Hospital Medical Center, New YorkSconosciutoCancro al cervello metastaticoStati Uniti