A Simple Method to Determine the Reflex Latency During WBV
A Simple Method to Determine the Reflex Latency During Whole Body Vibration
The purpose of this study was to examine the validity of the measurement method based on observation of vibration stimulation-MUAP (motor unit action potential) (1 to 1) matching that helps to measure human WBV-induced muscular reflex latency and to compare these results with the latency determination obtained using the classical methods. The investigators' principle hypothesis is that the simple method is capable of determining the WBV induced reflex response latency as reliably as the complex methods described earlier.
To achieve this goal, the investigators have averaged the electrical responses of the soleus muscle (sEMG and multi motor unit (MMU) potential) against the vertical force data obtained during all the six vibration frequencies tested in this study. The investigators have then combined all the averaged EMG data belonging to six different vibration frequencies to generate the 'cumulative averaged' sEMG and MMU for each subject. The investigators have also obtained the standard error for the cumulative averaged records which indicated the WBV-induced muscular reflex (WBV-IMR) latency.
Přehled studie
Postavení
Podmínky
Intervence / Léčba
Detailní popis
Subjects Five healthy volunteers will be participated in the study.
Procedures During WBV, the subjects will be asked to stand upright on a vibration platform (PowerPlate Pro5, London, United Kingdom). Their hips and knees will be in a neutral position. Subjects will be barefooted, and no sponge or foam will be placed between the vibration platform and their feet (Figure 1). The whole plate oscillates with a linear movement upward and downward. Vibration amplitude is 2.2 mm. WBV frequencies will be varied randomly to cover the following six frequencies: 25, 30, 35, 40,45 and 50 Hz. Each frequency lasts for 60 seconds and there will be a 15 seconds rest in between different frequencies.
A load sensor (FC2331-0000-2000L Compression Load Sensor, France) will be fixed on the WBV platform in order to be able to determine induced muscular response latency. Subjects will be positioned on the WBV platform such that their right heel will be placed on the load sensor.
Recordings MMUs, surface EMG (sEMG) and force recordings will be simultaneously done using the Powerlab data acquisition system (ADInstruments, Oxford, United Kingdom). A sampling frequency of 40 kiloHertz (kHz) will be used. Data will be analyzed offline using the MATLAB (R2012a 7.14.0.739).
In order to record sEMG, Ag/AgCl electrodes [KENDALL ® Arbo] with a disc radius of 10 mm will be placed 20 mm apart on the right soleus muscle belly, on shaved skin cleaned with alcohol. The ground electrode will be placed on the lateral malleolus.
To record MMU activity, a pair of Teflon® insulated silver wires (75 µm in core diameter) will be used. About 3 mm of the tips of the silver wires will be stripped of their Teflon ® coating in order to be able to record the activity of several motor units. The pair of wires will be inserted into the right soleus muscle with a 25 G needle. Needle will be immediately withdrawn leaving the fish-hooked wires in the muscle. A lip-clip electrode will be used as the ground electrode.
All cables will be carefully taped to the skin to minimize mechanical artifacts.
The subjects will be instructed to relax their muscles throughout the recordings and were trained using EMG feedback to this end. WBV may impair the sense of balance and muscles may be activated to restore balance. To overcome this issue, the subjects will be familiarized with WBV with a 15 s session of WBV, the subjects will be asked to use the handles of the WBV device to secure their balance and the base of support (distance between the heels) will be adjusted as wide. The distance between the heels usually will be about 25 cm.
Filtering and Rectification regimens All force sensor recordings will be 5 Hz high-pass filtered. All sEMG recordings will be 80 - 500 Hz band-pass filtered (Butterworth 1st order) and full-wave rectified to overcome movement artifacts. All MMU recordings will be 100-5000 Hz band-pass filtered (Butterworth 1st order) and full-wave rectified.
WBV - induced muscular reflex (WBV-IMR) latency
In a previous study, right soleus muscle sEMG measurement and force sensor measurement that is placed under right heel during WBV were taken synchronously and it was found that vibration stimulation and MUAPs would be matched 1 to 1. In this study that is based on the previous observation, it is predicted that it is possible to calculate latency by using averaging method.
All MMU and sEMG data will be analyzed by applying respectively filtering, rectification and differentiation with MATLAB (R2012a 7.14.0.739). Data analysis will be performed in two stages:
- Detection of the moment of mechanical stimulation threshold (Force Sensor Data Averaging): Force sensor data will be averaged by using Spike triggered averaging (STA) method. For this, 50 seconds of constant time intervals of preset vibration frequency in a WBV set will be used. All the positive peaks in both MMU and sEMG traces will be marked. For all the positive peaks, the force sensor trace will be segmented covering 75 ms previous positive peak. After, cumulative average of these 6 vibration sets will be averaged. The standard error on the cumulative averaged force records will be calculated. The lowest point of standard error on force sensor averaging graphic will be considered as the starting point of mechanical stimulation that triggers the muscle response.
- Determination of the MUAP onset: EMG data averaging method and manual method (vibration stimulus and MUAP coupling) will be used.
Typ studie
Zápis (Aktuální)
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
-
İstanbul, Krocan
- Bağcılar Training & Research Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Young adult (20-45 yrs)
- Healthy
- Right handed
Exclusion Criteria:
- Any health problems
- Left handed
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Základní věda
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: Whole-body vibration
A new method for muscle reflex latency measurement
|
High amplitude whole-body vibration
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Časové okno |
|---|---|
|
Latency measurement method
Časové okno: 1 day
|
1 day
|
Spolupracovníci a vyšetřovatelé
Vyšetřovatelé
- Studijní židle: ILHAN KARACAN, MD, Bagcilar Training & Research Hospital
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
- BEAH FTR-9
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
produkt vyrobený a vyvážený z USA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na whole-body vibration
-
Deep BreezeDokončenoStenóza centrálních dýchacích cestSpojené státy, Francie, Německo, Japonsko
-
M.D. Anderson Cancer CenterDeep BreezeDokončeno
-
Singapore General HospitalDokončenoPlicní onemocnění | Onemocnění hrudníku | Plicní onemocnění | Nemoci dýchacích cestSingapur
-
University of MiamiHyperVibe Pty LtdStaženoSložení těla, prospěšné | Fyzická zdatnostSpojené státy
-
Kaplan Medical CenterNeznámý
-
International Centre for Diarrhoeal Disease Research...NáborZvýšení laktátu v krvi | Těžká sepse se septickým šokemBangladéš
-
Point DesignsEunice Kennedy Shriver National Institute of Child Health and Human Development... a další spolupracovníciNáborAmputace; Traumatické, Ruka | Amputace, vrozenáSpojené státy
-
Point DesignsUniversity of Colorado, Denver; Eunice Kennedy Shriver National Institute of...StaženoAmputace; Traumatické, Ruka | Amputace, vrozenáSpojené státy
-
Point DesignsUniversity of Colorado, Denver; Arm DynamicsDokončenoAmputace; Traumatické, RukaSpojené státy
-
University of StellenboschLondon School of Hygiene and Tropical Medicine; Makerere University; Leiden University... a další spolupracovníciNáborTuberkulóza | Tuberkulóza, plicníJižní Afrika