Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Finite Element Study of Biomechanical Changes After Unilateral Hemilamina and Facet Joint Resection of Cervical Spine

4. juli 2021 opdateret af: Peking University Third Hospital
Finite element method was used to simulate unilateral hemilaminectomy of cervical spine and facet joint resection of different degrees, and the range of motion and the stress changes of ligament, intervertebral disc and endplate were calculated immediately after operation

Studieoversigt

Status

Rekruttering

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

The finite element method was used to simulate unilateral hemilaminectomy of cervical spine and different degrees of facet joint resection, and the range of motion and the stress changes of ligaments, intervertebral discs and endplates were calculated immediately after the operation.

Finite element method was used to simulate unilateral hemilaminectomy of cervical spine and facet joint resection of different degrees, and the range of motion and the stress changes of ligament, intervertebral disc and endplate were calculated immediately after operation.

Study Design:

This study is a retrospective and general observational study.In this study, a young patient who was hospitalized in the Neurosurgery Department of the Third Hospital of Beijing University of Medicine and had undergone CT examination of cervical vertebra was selected. The patient had no cervical bony deformity, no cervical degeneration, and no history of trauma.

CT imaging data were collected, and a three-dimensional finite element model of C2-T1 segment of human cervical spine was established by finite element software. On the basis of this model, two and three levels of unilateral hemilamina and different degrees of facet joint resection were simulated.The lower end of the T1 vertebral body was fixed as the boundary condition, and three loading modes were adopted, namely, 2.0nm pure torque was applied to the upper surface of the C2 vertebral body along the sagittal plane, coronal plane and axial plane, respectively.The range of motion between vertebral segments was calculated and compared in different lamina surgical models. The tension of ligaments, the pressure of endplates and the pressure of intervertebral discs were obtained by finite element post-processing

Undersøgelsestype

Observationel

Tilmelding (Forventet)

1

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

  • Navn: Zhen-Yu Wang
  • Telefonnummer: +86 136 2134 9770
  • E-mail: wzyu502@163.com

Studiesteder

    • Beijing
      • Beijing, Beijing, Kina, 100191
        • Rekruttering
        • Peking University Third Hospital
        • Kontakt:

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 35 år (Voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Prøveudtagningsmetode

Ikke-sandsynlighedsprøve

Studiebefolkning

A young patient hospitalized in the Department of Neurosurgery of the Third Hospital of Beijing University of Medicine underwent CT examination of cervical vertebrae. The patient had no cervical bony deformity, no cervical degeneration, and no history of trauma

Beskrivelse

Inclusion Criteria:

A young patient hospitalized in the Department of Neurosurgery of the Third Hospital of Beijing University of Medicine underwent CT examination of cervical vertebrae.

Exclusion Criteria:

Cervical bony deformity Cervical degeneration History of trauma

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

Kohorter og interventioner

Gruppe / kohorte
Intervention / Behandling
Study object
A young patient hospitalized in the Department of Neurosurgery of the Third Hospital of Beijing University of Medicine underwent CT examination of cervical vertebrae. The patient had no cervical bony deformity, no cervical degeneration, and no history of trauma
Hospitalization

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Verification of the model
Tidsramme: Through study completion, an average of 1 year
In this study, the pure torque of 2.0Nm was applied to the upper surface of C2 vertebral body along the 1, 2 and 3 coordinates according to the right hand helical rule to generate the corresponding pure torque in the sagittal plane, coronal plane and axial plane, and to simulate the cervical spine flexion and extension, lateral bending and left-right rotation in real life
Through study completion, an average of 1 year

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Samarbejdspartnere

Efterforskere

  • Studiestol: Zhen-Yu Wang, Peking University Third Hospital
  • Studieleder: Qi-Guo Rong, Peking University

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. februar 2018

Primær færdiggørelse (Forventet)

1. januar 2022

Studieafslutning (Forventet)

1. januar 2022

Datoer for studieregistrering

Først indsendt

27. juni 2021

Først indsendt, der opfyldte QC-kriterier

4. juli 2021

Først opslået (Faktiske)

12. juli 2021

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

12. juli 2021

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

4. juli 2021

Sidst verificeret

1. juni 2021

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • M2018028

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner