Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Finite Element Study of Biomechanical Changes After Unilateral Hemilamina and Facet Joint Resection of Cervical Spine

4 juillet 2021 mis à jour par: Peking University Third Hospital
Finite element method was used to simulate unilateral hemilaminectomy of cervical spine and facet joint resection of different degrees, and the range of motion and the stress changes of ligament, intervertebral disc and endplate were calculated immediately after operation

Aperçu de l'étude

Statut

Recrutement

Les conditions

Intervention / Traitement

Description détaillée

The finite element method was used to simulate unilateral hemilaminectomy of cervical spine and different degrees of facet joint resection, and the range of motion and the stress changes of ligaments, intervertebral discs and endplates were calculated immediately after the operation.

Finite element method was used to simulate unilateral hemilaminectomy of cervical spine and facet joint resection of different degrees, and the range of motion and the stress changes of ligament, intervertebral disc and endplate were calculated immediately after operation.

Study Design:

This study is a retrospective and general observational study.In this study, a young patient who was hospitalized in the Neurosurgery Department of the Third Hospital of Beijing University of Medicine and had undergone CT examination of cervical vertebra was selected. The patient had no cervical bony deformity, no cervical degeneration, and no history of trauma.

CT imaging data were collected, and a three-dimensional finite element model of C2-T1 segment of human cervical spine was established by finite element software. On the basis of this model, two and three levels of unilateral hemilamina and different degrees of facet joint resection were simulated.The lower end of the T1 vertebral body was fixed as the boundary condition, and three loading modes were adopted, namely, 2.0nm pure torque was applied to the upper surface of the C2 vertebral body along the sagittal plane, coronal plane and axial plane, respectively.The range of motion between vertebral segments was calculated and compared in different lamina surgical models. The tension of ligaments, the pressure of endplates and the pressure of intervertebral discs were obtained by finite element post-processing

Type d'étude

Observationnel

Inscription (Anticipé)

1

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

  • Nom: Zhen-Yu Wang
  • Numéro de téléphone: +86 136 2134 9770
  • E-mail: wzyu502@163.com

Lieux d'étude

    • Beijing
      • Beijing, Beijing, Chine, 100191
        • Recrutement
        • Peking University Third Hospital
        • Contact:
          • Zhen-Yu Wang
          • Numéro de téléphone: +86 136 2134 9770
          • E-mail: wzyu502@163.com

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 35 ans (Adulte)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

A young patient hospitalized in the Department of Neurosurgery of the Third Hospital of Beijing University of Medicine underwent CT examination of cervical vertebrae. The patient had no cervical bony deformity, no cervical degeneration, and no history of trauma

La description

Inclusion Criteria:

A young patient hospitalized in the Department of Neurosurgery of the Third Hospital of Beijing University of Medicine underwent CT examination of cervical vertebrae.

Exclusion Criteria:

Cervical bony deformity Cervical degeneration History of trauma

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Study object
A young patient hospitalized in the Department of Neurosurgery of the Third Hospital of Beijing University of Medicine underwent CT examination of cervical vertebrae. The patient had no cervical bony deformity, no cervical degeneration, and no history of trauma
Hospitalization

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Verification of the model
Délai: Through study completion, an average of 1 year
In this study, the pure torque of 2.0Nm was applied to the upper surface of C2 vertebral body along the 1, 2 and 3 coordinates according to the right hand helical rule to generate the corresponding pure torque in the sagittal plane, coronal plane and axial plane, and to simulate the cervical spine flexion and extension, lateral bending and left-right rotation in real life
Through study completion, an average of 1 year

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Collaborateurs

Les enquêteurs

  • Chaise d'étude: Zhen-Yu Wang, Peking University Third Hospital
  • Directeur d'études: Qi-Guo Rong, Peking University

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

1 février 2018

Achèvement primaire (Anticipé)

1 janvier 2022

Achèvement de l'étude (Anticipé)

1 janvier 2022

Dates d'inscription aux études

Première soumission

27 juin 2021

Première soumission répondant aux critères de contrôle qualité

4 juillet 2021

Première publication (Réel)

12 juillet 2021

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

12 juillet 2021

Dernière mise à jour soumise répondant aux critères de contrôle qualité

4 juillet 2021

Dernière vérification

1 juin 2021

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .