Finite Element Study of Biomechanical Changes After Unilateral Hemilamina and Facet Joint Resection of Cervical Spine

4. juli 2021 oppdatert av: Peking University Third Hospital
Finite element method was used to simulate unilateral hemilaminectomy of cervical spine and facet joint resection of different degrees, and the range of motion and the stress changes of ligament, intervertebral disc and endplate were calculated immediately after operation

Studieoversikt

Status

Rekruttering

Intervensjon / Behandling

Detaljert beskrivelse

The finite element method was used to simulate unilateral hemilaminectomy of cervical spine and different degrees of facet joint resection, and the range of motion and the stress changes of ligaments, intervertebral discs and endplates were calculated immediately after the operation.

Finite element method was used to simulate unilateral hemilaminectomy of cervical spine and facet joint resection of different degrees, and the range of motion and the stress changes of ligament, intervertebral disc and endplate were calculated immediately after operation.

Study Design:

This study is a retrospective and general observational study.In this study, a young patient who was hospitalized in the Neurosurgery Department of the Third Hospital of Beijing University of Medicine and had undergone CT examination of cervical vertebra was selected. The patient had no cervical bony deformity, no cervical degeneration, and no history of trauma.

CT imaging data were collected, and a three-dimensional finite element model of C2-T1 segment of human cervical spine was established by finite element software. On the basis of this model, two and three levels of unilateral hemilamina and different degrees of facet joint resection were simulated.The lower end of the T1 vertebral body was fixed as the boundary condition, and three loading modes were adopted, namely, 2.0nm pure torque was applied to the upper surface of the C2 vertebral body along the sagittal plane, coronal plane and axial plane, respectively.The range of motion between vertebral segments was calculated and compared in different lamina surgical models. The tension of ligaments, the pressure of endplates and the pressure of intervertebral discs were obtained by finite element post-processing

Studietype

Observasjonsmessig

Registrering (Forventet)

1

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

  • Navn: Zhen-Yu Wang
  • Telefonnummer: +86 136 2134 9770
  • E-post: wzyu502@163.com

Studiesteder

    • Beijing
      • Beijing, Beijing, Kina, 100191
        • Rekruttering
        • Peking University Third Hospital
        • Ta kontakt med:

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år til 35 år (Voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

A young patient hospitalized in the Department of Neurosurgery of the Third Hospital of Beijing University of Medicine underwent CT examination of cervical vertebrae. The patient had no cervical bony deformity, no cervical degeneration, and no history of trauma

Beskrivelse

Inclusion Criteria:

A young patient hospitalized in the Department of Neurosurgery of the Third Hospital of Beijing University of Medicine underwent CT examination of cervical vertebrae.

Exclusion Criteria:

Cervical bony deformity Cervical degeneration History of trauma

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

Kohorter og intervensjoner

Gruppe / Kohort
Intervensjon / Behandling
Study object
A young patient hospitalized in the Department of Neurosurgery of the Third Hospital of Beijing University of Medicine underwent CT examination of cervical vertebrae. The patient had no cervical bony deformity, no cervical degeneration, and no history of trauma
Hospitalization

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Verification of the model
Tidsramme: Through study completion, an average of 1 year
In this study, the pure torque of 2.0Nm was applied to the upper surface of C2 vertebral body along the 1, 2 and 3 coordinates according to the right hand helical rule to generate the corresponding pure torque in the sagittal plane, coronal plane and axial plane, and to simulate the cervical spine flexion and extension, lateral bending and left-right rotation in real life
Through study completion, an average of 1 year

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Samarbeidspartnere

Etterforskere

  • Studiestol: Zhen-Yu Wang, Peking University Third Hospital
  • Studieleder: Qi-Guo Rong, Peking University

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

1. februar 2018

Primær fullføring (Forventet)

1. januar 2022

Studiet fullført (Forventet)

1. januar 2022

Datoer for studieregistrering

Først innsendt

27. juni 2021

Først innsendt som oppfylte QC-kriteriene

4. juli 2021

Først lagt ut (Faktiske)

12. juli 2021

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

12. juli 2021

Siste oppdatering sendt inn som oppfylte QC-kriteriene

4. juli 2021

Sist bekreftet

1. juni 2021

Mer informasjon

Begreper knyttet til denne studien

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere