Transjugular Approach for Implantation of Active Fixation Leadless Pacemakers: A Feasibility Study

This study is a prospective, single-arm, single-center feasibility study evaluating the safety and feasibility of transjugular (internal jugular vein) implantation of the Aveir VR leadless ventricular pacemaker in patients requiring ventricular pacing. A total of 15 patients will be enrolled at Xijing Hospital. The primary objective is to assess procedural feasibility and acute safety (from intraoperative to 48 hours post-procedure). Secondary objectives include short-term (1 to 3 months) pacing parameter stability (threshold, R-wave amplitude, impedance), technical success rate, procedure-related metrics, and adverse event rates.

Studieoversigt

Status

Ikke rekrutterer endnu

Intervention / Behandling

Detaljeret beskrivelse

Background: Leadless pacemakers have emerged as an important alternative to conventional transvenous pacing systems, offering advantages such as reduced pocket-related complications and improved patient tolerance. The Aveir VR (Abbott) is an active-fixation leadless ventricular pacemaker with a retractable helix and retrievable design. While the femoral approach is standard, some patients have contraindications to femoral access (e.g., venous occlusion, severe obesity). The internal jugular vein approach offers a potential alternative, but clinical data-particularly from China-remain limited.

Objectives: To evaluate the feasibility and acute (intraoperative to 48h) safety of transjugular implantation of Aveir VR, and to assess short-term (1-3 months) pacing parameter stability and safety in a Chinese population.

Study Design: Prospective, single-arm, single-center feasibility study. Fifteen patients aged 18-85 years with symptomatic bradycardia requiring ventricular pacing will be enrolled. The procedure will be performed via the right internal jugular vein (or external jugular if needed) under local anesthesia. Pacing parameters (threshold, R-wave amplitude, impedance) will be tested intraoperatively and at 1-month and 3-month follow-up. Implant location (right ventricular septal vs. free wall) will be assessed by echocardiography or cardiac CT before discharge. Safety will be evaluated through adverse event monitoring from consent through 3 months post-procedure. Descriptive statistics will be used; no formal hypothesis testing will be performed given the exploratory feasibility nature of the study.

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

15

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

  • Navn: Min Shen, MD, PhD
  • Telefonnummer: +86-18099773953
  • E-mail: 261726782@qq.com

Studiesteder

    • Shaanxi
      • Xi'an, Shaanxi, Kina, 710032
        • Xijing Hospital, The First Affiliated Hospital of Air Force Medical University
        • Kontakt:

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Voksen
  • Ældre voksen

Tager imod sunde frivillige

Ingen

Beskrivelse

Inclusion Criteria:

  1. Aged 18 to 85 years, regardless of gender.
  2. Symptomatic bradyarrhythmia meeting the ventricular pacing indications recommended by the 2023 ACC/AHA/HRS Guideline for the Evaluation and Management of Bradyarrhythmias, the 2020 Chinese Expert Consensus on the Evaluation and Management of Patients with Bradycardia and Conduction Disorders, and the 2022 Chinese Expert Consensus on the Clinical Application of Leadless Pacemakers, including any of the following conditions:

    • Third-degree or advanced atrioventricular (AV) block;
    • Second-degree type II AV block, alternating bundle branch block, or bifascicular/trifascicular block with intermittent advanced/third-degree AV block;
    • Adult congenital complete AV block; persistent irreversible advanced/third-degree AV block following myocardial infarction or cardiac surgery;
    • Symptomatic bradycardia (e.g., dizziness, presyncope, syncope, fatigue, decreased exercise tolerance) or sick sinus syndrome (including chronotropic incompetence and tachy-brady syndrome);
    • Drug-induced persistent symptomatic bradycardia with no alternative treatment options;
    • Atrial fibrillation with slow ventricular response requiring long-term ventricular pacing;
    • New-onset persistent complete left bundle branch block after TAVR, or new-onset advanced AV block after hypertrophic cardiomyopathy ablation;
    • Neuromuscular disease, infiltrative cardiomyopathy, or adult congenital heart disease with progressive AV/branch conduction abnormalities and bradycardia-related symptoms;
    • High infection risk populations (e.g., recurrent pacing system infection, diabetes mellitus, long-term corticosteroid use, end-stage renal disease on dialysis) or patients with abnormal conventional pacing access or at extremely high risk of conventional pacing lead complications.
  3. Anatomical feasibility and vascular access assessment:

    • Preoperative imaging confirms suitable right internal jugular vein access to accommodate the delivery sheath, without thrombosis, severe stenosis, or anatomical malformations;
    • Right ventricular anatomy is suitable with adequate trabeculation to support active fixation of the leadless pacemaker, without severe structural abnormalities;
    • Priority for enrollment: patients with limited femoral or inferior vena cava access (e.g., iliac/inferior vena cava stenosis, thrombosis, prior venous surgery, obesity precluding femoral access).
  4. New York Heart Association (NYHA) functional class ≤ III, and expected survival > 1 year.
  5. Able to cooperate with preoperative evaluation, intraoperative procedure, and 3-month follow-up.
  6. Voluntarily signs written informed consent and agrees to complete all scheduled observations per the study protocol.

Exclusion Criteria:

  1. Anatomical malformations, severe stenosis, occlusion, or thrombosis of the internal jugular vein or superior vena cava that preclude transjugular access for the procedure.
  2. Abnormal right ventricular anatomy, including but not limited to right ventricular hypoplasia, severe right ventricular dilation, or severe right ventricular myocardial fibrosis, preventing safe implantation of an active-fixation leadless ventricular pacemaker.
  3. Severe tricuspid regurgitation, or status post-mechanical tricuspid valve replacement, significantly affecting pacemaker implantation, device fixation, or function.
  4. NYHA functional class IV, or refractory heart failure, cardiogenic shock, rendering the patient unable to tolerate the procedure and perioperative management.
  5. Severe hepatic or renal impairment (eGFR < 30 mL/min/1.73m², severe liver dysfunction), coagulopathy, or active bleeding disorders constituting clear surgical contraindications.
  6. Confirmed allergy or severe intolerance to leadless pacemaker materials, intraoperative contrast media, or anesthetic agents.
  7. Prior implantation of other cardiovascular implantable electronic devices (e.g., pacemaker, ICD, CRT) or retained intracardiac leads/devices that would interfere with the current implantation or device function.
  8. Advanced malignancy, severe active infection, active autoimmune disease, or other serious systemic conditions with an expected survival < 12 months, precluding completion of the 3-month follow-up.
  9. Pregnant or lactating women, or women planning pregnancy during the follow-up period.
  10. Psychiatric disorders, cognitive impairment, or inability to cooperate with preoperative evaluation, intraoperative procedure, or regular postoperative follow-up due to personal or geographic reasons.
  11. Concurrent participation in another cardiovascular device clinical trial that may interfere with the outcome assessment of this study.
  12. Any other condition deemed by the investigator to make the participant unsuitable for enrollment.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Experimental: Aveir VR Leadless Pacemaker
Participants will undergo transjugular implantation of the Aveir VR active-fixation leadless ventricular pacemaker. This experimental arm evaluates the procedure and device performance for ventricular pacing indications.
The Aveir VR leadless pacemaker is implanted via a transjugular (jugular vein) approach. This active-fixation device is placed in the right ventricle for ventricular pacing indications.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Rate of Participants with Sustained Successful Aveir VR Lead Implantation (evaluated by fluoroscopy and clinical-electrophysiological follow-up)
Tidsramme: Through 3 months post-procedure
The percentage of participants with sustained successful Aveir VR lead implantation via trans-jugular venous access at 3-month follow-up. Sustained implantation success is defined as intact lead position, stable pacing parameters, and absence of lead-related complications at the end of 3-month follow-up.
Through 3 months post-procedure
Acute adverse event rate
Tidsramme: Periprocedural and up to 48 hours
Incidence of adverse events within 48 hours post-procedure, measured as a percentage
Periprocedural and up to 48 hours

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Pacing Threshold (measured in volts)
Tidsramme: Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Pacing threshold of the Aveir VR lead, measured in volts, to evaluate threshold stability across follow-up time points.
Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
R-wave amplitude
Tidsramme: Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
R-wave amplitude measured in millivolts.
Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Lead impedance
Tidsramme: Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Lead impedance measured in ohms.
Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Technical success rate
Tidsramme: Periprocedural
Rate of technical success measured as a percentage.
Periprocedural
Duration of the Implantation Procedure (measured in minutes)
Tidsramme: Periprocedural
Total time duration of the leadless pacemaker implantation procedure, measured in minutes.
Periprocedural
Fluoroscopy time
Tidsramme: Periprocedural
Duration of fluoroscopy measured in minutes.
Periprocedural
Number of puncture attempts
Tidsramme: Periprocedural
Count of puncture attempts measured in number of times.
Periprocedural
Number of lead fixation attempts
Tidsramme: Periprocedural
Count of fixation attempts measured in number of times.
Periprocedural
Implantation site
Tidsramme: Periprocedural
Anatomical location of implantation recorded as a categorical variable.
Periprocedural
Correlation between site and parameters
Tidsramme: Up to 3 months
Pacing parameters by site
Up to 3 months
Adverse event incidence
Tidsramme: Through 3 months post-procedure
Overall incidence of adverse events measured as a percentage.
Through 3 months post-procedure
Serious adverse event incidence
Tidsramme: Through 3 months post-procedure
Incidence of serious adverse events measured as a percentage.
Through 3 months post-procedure
Device-related complication rate
Tidsramme: Through 3 months post-procedure
Rate of device-related complications measured as a percentage.
Through 3 months post-procedure

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Efterforskere

  • Ledende efterforsker: Min Shen, MD, PhD, Department of Cardiovascular Medicine, First Affiliated Hospital of Air Force Medical University

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

10. september 2026

Primær færdiggørelse (Anslået)

30. september 2027

Studieafslutning (Anslået)

31. december 2027

Datoer for studieregistrering

Først indsendt

21. august 2026

Først indsendt, der opfyldte QC-kriterier

30. august 2026

Først opslået (Faktiske)

3. september 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

3. september 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

30. august 2026

Sidst verificeret

1. august 2026

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

IPD-planbeskrivelse

his is a single-center feasibility study with a small sample size (n=15). Data sharing is not planned due to the limited statistical power and the difficulty in de-identifying such specific clinical data without undue risk.

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ja

produkt fremstillet i og eksporteret fra U.S.A.

Ja

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner