Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

Transjugular Approach for Implantation of Active Fixation Leadless Pacemakers

sunnuntai 30. elokuuta 2026 päivittänyt: Min Shen

Transjugular Approach for Implantation of Active Fixation Leadless Pacemakers: A Feasibility Study

This study is a prospective, single-arm, single-center feasibility study evaluating the safety and feasibility of transjugular (internal jugular vein) implantation of the Aveir VR leadless ventricular pacemaker in patients requiring ventricular pacing. A total of 15 patients will be enrolled at Xijing Hospital. The primary objective is to assess procedural feasibility and acute safety (from intraoperative to 48 hours post-procedure). Secondary objectives include short-term (1 to 3 months) pacing parameter stability (threshold, R-wave amplitude, impedance), technical success rate, procedure-related metrics, and adverse event rates.

Tutkimuksen yleiskatsaus

Yksityiskohtainen kuvaus

Background: Leadless pacemakers have emerged as an important alternative to conventional transvenous pacing systems, offering advantages such as reduced pocket-related complications and improved patient tolerance. The Aveir VR (Abbott) is an active-fixation leadless ventricular pacemaker with a retractable helix and retrievable design. While the femoral approach is standard, some patients have contraindications to femoral access (e.g., venous occlusion, severe obesity). The internal jugular vein approach offers a potential alternative, but clinical data-particularly from China-remain limited.

Objectives: To evaluate the feasibility and acute (intraoperative to 48h) safety of transjugular implantation of Aveir VR, and to assess short-term (1-3 months) pacing parameter stability and safety in a Chinese population.

Study Design: Prospective, single-arm, single-center feasibility study. Fifteen patients aged 18-85 years with symptomatic bradycardia requiring ventricular pacing will be enrolled. The procedure will be performed via the right internal jugular vein (or external jugular if needed) under local anesthesia. Pacing parameters (threshold, R-wave amplitude, impedance) will be tested intraoperatively and at 1-month and 3-month follow-up. Implant location (right ventricular septal vs. free wall) will be assessed by echocardiography or cardiac CT before discharge. Safety will be evaluated through adverse event monitoring from consent through 3 months post-procedure. Descriptive statistics will be used; no formal hypothesis testing will be performed given the exploratory feasibility nature of the study.

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

15

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskeluyhteys

  • Nimi: Min Shen, MD, PhD
  • Puhelinnumero: +86-18099773953
  • Sähköposti: 261726782@qq.com

Opiskelupaikat

    • Shaanxi
      • Xi'an, Shaanxi, Kiina, 710032
        • Xijing Hospital, The First Affiliated Hospital of Air Force Medical University
        • Ottaa yhteyttä:
          • Min Shen, MD, PhD
          • Puhelinnumero: +86-18099773953
          • Sähköposti: 261726782@qq.com

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Aikuinen
  • Vanhempi Aikuinen

Hyväksyy terveitä vapaaehtoisia

Ei

Kuvaus

Inclusion Criteria:

  1. Aged 18 to 85 years, regardless of gender.
  2. Symptomatic bradyarrhythmia meeting the ventricular pacing indications recommended by the 2023 ACC/AHA/HRS Guideline for the Evaluation and Management of Bradyarrhythmias, the 2020 Chinese Expert Consensus on the Evaluation and Management of Patients with Bradycardia and Conduction Disorders, and the 2022 Chinese Expert Consensus on the Clinical Application of Leadless Pacemakers, including any of the following conditions:

    • Third-degree or advanced atrioventricular (AV) block;
    • Second-degree type II AV block, alternating bundle branch block, or bifascicular/trifascicular block with intermittent advanced/third-degree AV block;
    • Adult congenital complete AV block; persistent irreversible advanced/third-degree AV block following myocardial infarction or cardiac surgery;
    • Symptomatic bradycardia (e.g., dizziness, presyncope, syncope, fatigue, decreased exercise tolerance) or sick sinus syndrome (including chronotropic incompetence and tachy-brady syndrome);
    • Drug-induced persistent symptomatic bradycardia with no alternative treatment options;
    • Atrial fibrillation with slow ventricular response requiring long-term ventricular pacing;
    • New-onset persistent complete left bundle branch block after TAVR, or new-onset advanced AV block after hypertrophic cardiomyopathy ablation;
    • Neuromuscular disease, infiltrative cardiomyopathy, or adult congenital heart disease with progressive AV/branch conduction abnormalities and bradycardia-related symptoms;
    • High infection risk populations (e.g., recurrent pacing system infection, diabetes mellitus, long-term corticosteroid use, end-stage renal disease on dialysis) or patients with abnormal conventional pacing access or at extremely high risk of conventional pacing lead complications.
  3. Anatomical feasibility and vascular access assessment:

    • Preoperative imaging confirms suitable right internal jugular vein access to accommodate the delivery sheath, without thrombosis, severe stenosis, or anatomical malformations;
    • Right ventricular anatomy is suitable with adequate trabeculation to support active fixation of the leadless pacemaker, without severe structural abnormalities;
    • Priority for enrollment: patients with limited femoral or inferior vena cava access (e.g., iliac/inferior vena cava stenosis, thrombosis, prior venous surgery, obesity precluding femoral access).
  4. New York Heart Association (NYHA) functional class ≤ III, and expected survival > 1 year.
  5. Able to cooperate with preoperative evaluation, intraoperative procedure, and 3-month follow-up.
  6. Voluntarily signs written informed consent and agrees to complete all scheduled observations per the study protocol.

Exclusion Criteria:

  1. Anatomical malformations, severe stenosis, occlusion, or thrombosis of the internal jugular vein or superior vena cava that preclude transjugular access for the procedure.
  2. Abnormal right ventricular anatomy, including but not limited to right ventricular hypoplasia, severe right ventricular dilation, or severe right ventricular myocardial fibrosis, preventing safe implantation of an active-fixation leadless ventricular pacemaker.
  3. Severe tricuspid regurgitation, or status post-mechanical tricuspid valve replacement, significantly affecting pacemaker implantation, device fixation, or function.
  4. NYHA functional class IV, or refractory heart failure, cardiogenic shock, rendering the patient unable to tolerate the procedure and perioperative management.
  5. Severe hepatic or renal impairment (eGFR < 30 mL/min/1.73m², severe liver dysfunction), coagulopathy, or active bleeding disorders constituting clear surgical contraindications.
  6. Confirmed allergy or severe intolerance to leadless pacemaker materials, intraoperative contrast media, or anesthetic agents.
  7. Prior implantation of other cardiovascular implantable electronic devices (e.g., pacemaker, ICD, CRT) or retained intracardiac leads/devices that would interfere with the current implantation or device function.
  8. Advanced malignancy, severe active infection, active autoimmune disease, or other serious systemic conditions with an expected survival < 12 months, precluding completion of the 3-month follow-up.
  9. Pregnant or lactating women, or women planning pregnancy during the follow-up period.
  10. Psychiatric disorders, cognitive impairment, or inability to cooperate with preoperative evaluation, intraoperative procedure, or regular postoperative follow-up due to personal or geographic reasons.
  11. Concurrent participation in another cardiovascular device clinical trial that may interfere with the outcome assessment of this study.
  12. Any other condition deemed by the investigator to make the participant unsuitable for enrollment.

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Ei käytössä
  • Inventiomalli: Yksittäinen ryhmätehtävä
  • Naamiointi: Ei mitään (avoin tarra)

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Kokeellinen: Experimental: Aveir VR Leadless Pacemaker
Participants will undergo transjugular implantation of the Aveir VR active-fixation leadless ventricular pacemaker. This experimental arm evaluates the procedure and device performance for ventricular pacing indications.
The Aveir VR leadless pacemaker is implanted via a transjugular (jugular vein) approach. This active-fixation device is placed in the right ventricle for ventricular pacing indications.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Rate of Participants with Sustained Successful Aveir VR Lead Implantation (evaluated by fluoroscopy and clinical-electrophysiological follow-up)
Aikaikkuna: Through 3 months post-procedure
The percentage of participants with sustained successful Aveir VR lead implantation via trans-jugular venous access at 3-month follow-up. Sustained implantation success is defined as intact lead position, stable pacing parameters, and absence of lead-related complications at the end of 3-month follow-up.
Through 3 months post-procedure
Acute adverse event rate
Aikaikkuna: Periprocedural and up to 48 hours
Incidence of adverse events within 48 hours post-procedure, measured as a percentage
Periprocedural and up to 48 hours

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Pacing Threshold (measured in volts)
Aikaikkuna: Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Pacing threshold of the Aveir VR lead, measured in volts, to evaluate threshold stability across follow-up time points.
Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
R-wave amplitude
Aikaikkuna: Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
R-wave amplitude measured in millivolts.
Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Lead impedance
Aikaikkuna: Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Lead impedance measured in ohms.
Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Technical success rate
Aikaikkuna: Periprocedural
Rate of technical success measured as a percentage.
Periprocedural
Duration of the Implantation Procedure (measured in minutes)
Aikaikkuna: Periprocedural
Total time duration of the leadless pacemaker implantation procedure, measured in minutes.
Periprocedural
Fluoroscopy time
Aikaikkuna: Periprocedural
Duration of fluoroscopy measured in minutes.
Periprocedural
Number of puncture attempts
Aikaikkuna: Periprocedural
Count of puncture attempts measured in number of times.
Periprocedural
Number of lead fixation attempts
Aikaikkuna: Periprocedural
Count of fixation attempts measured in number of times.
Periprocedural
Implantation site
Aikaikkuna: Periprocedural
Anatomical location of implantation recorded as a categorical variable.
Periprocedural
Correlation between site and parameters
Aikaikkuna: Up to 3 months
Pacing parameters by site
Up to 3 months
Adverse event incidence
Aikaikkuna: Through 3 months post-procedure
Overall incidence of adverse events measured as a percentage.
Through 3 months post-procedure
Serious adverse event incidence
Aikaikkuna: Through 3 months post-procedure
Incidence of serious adverse events measured as a percentage.
Through 3 months post-procedure
Device-related complication rate
Aikaikkuna: Through 3 months post-procedure
Rate of device-related complications measured as a percentage.
Through 3 months post-procedure

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Sponsori

Tutkijat

  • Päätutkija: Min Shen, MD, PhD, Department of Cardiovascular Medicine, First Affiliated Hospital of Air Force Medical University

Julkaisuja ja hyödyllisiä linkkejä

Tutkimusta koskevien tietojen syöttämisestä vastaava henkilö toimittaa nämä julkaisut vapaaehtoisesti. Nämä voivat koskea mitä tahansa tutkimukseen liittyvää.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Arvioitu)

Torstai 10. syyskuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Torstai 30. syyskuuta 2027

Opintojen valmistuminen (Arvioitu)

Perjantai 31. joulukuuta 2027

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Perjantai 21. elokuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Sunnuntai 30. elokuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Torstai 3. syyskuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Torstai 3. syyskuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Sunnuntai 30. elokuuta 2026

Viimeksi vahvistettu

Lauantai 1. elokuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

EI

IPD-suunnitelman kuvaus

his is a single-center feasibility study with a small sample size (n=15). Data sharing is not planned due to the limited statistical power and the difficulty in de-identifying such specific clinical data without undue risk.

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Joo

Yhdysvalloissa valmistettu ja sieltä viety tuote

Joo

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa