Transjugular Approach for Implantation of Active Fixation Leadless Pacemakers: A Feasibility Study

This study is a prospective, single-arm, single-center feasibility study evaluating the safety and feasibility of transjugular (internal jugular vein) implantation of the Aveir VR leadless ventricular pacemaker in patients requiring ventricular pacing. A total of 15 patients will be enrolled at Xijing Hospital. The primary objective is to assess procedural feasibility and acute safety (from intraoperative to 48 hours post-procedure). Secondary objectives include short-term (1 to 3 months) pacing parameter stability (threshold, R-wave amplitude, impedance), technical success rate, procedure-related metrics, and adverse event rates.

Visão geral do estudo

Descrição detalhada

Background: Leadless pacemakers have emerged as an important alternative to conventional transvenous pacing systems, offering advantages such as reduced pocket-related complications and improved patient tolerance. The Aveir VR (Abbott) is an active-fixation leadless ventricular pacemaker with a retractable helix and retrievable design. While the femoral approach is standard, some patients have contraindications to femoral access (e.g., venous occlusion, severe obesity). The internal jugular vein approach offers a potential alternative, but clinical data-particularly from China-remain limited.

Objectives: To evaluate the feasibility and acute (intraoperative to 48h) safety of transjugular implantation of Aveir VR, and to assess short-term (1-3 months) pacing parameter stability and safety in a Chinese population.

Study Design: Prospective, single-arm, single-center feasibility study. Fifteen patients aged 18-85 years with symptomatic bradycardia requiring ventricular pacing will be enrolled. The procedure will be performed via the right internal jugular vein (or external jugular if needed) under local anesthesia. Pacing parameters (threshold, R-wave amplitude, impedance) will be tested intraoperatively and at 1-month and 3-month follow-up. Implant location (right ventricular septal vs. free wall) will be assessed by echocardiography or cardiac CT before discharge. Safety will be evaluated through adverse event monitoring from consent through 3 months post-procedure. Descriptive statistics will be used; no formal hypothesis testing will be performed given the exploratory feasibility nature of the study.

Tipo de estudo

Intervencional

Inscrição (Estimado)

15

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

  • Nome: Min Shen, MD, PhD
  • Número de telefone: +86-18099773953
  • E-mail: 261726782@qq.com

Locais de estudo

    • Shaanxi
      • Xi'an, Shaanxi, China, 710032
        • Xijing Hospital, The First Affiliated Hospital of Air Force Medical University
        • Contato:
          • Min Shen, MD, PhD
          • Número de telefone: +86-18099773953
          • E-mail: 261726782@qq.com

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  1. Aged 18 to 85 years, regardless of gender.
  2. Symptomatic bradyarrhythmia meeting the ventricular pacing indications recommended by the 2023 ACC/AHA/HRS Guideline for the Evaluation and Management of Bradyarrhythmias, the 2020 Chinese Expert Consensus on the Evaluation and Management of Patients with Bradycardia and Conduction Disorders, and the 2022 Chinese Expert Consensus on the Clinical Application of Leadless Pacemakers, including any of the following conditions:

    • Third-degree or advanced atrioventricular (AV) block;
    • Second-degree type II AV block, alternating bundle branch block, or bifascicular/trifascicular block with intermittent advanced/third-degree AV block;
    • Adult congenital complete AV block; persistent irreversible advanced/third-degree AV block following myocardial infarction or cardiac surgery;
    • Symptomatic bradycardia (e.g., dizziness, presyncope, syncope, fatigue, decreased exercise tolerance) or sick sinus syndrome (including chronotropic incompetence and tachy-brady syndrome);
    • Drug-induced persistent symptomatic bradycardia with no alternative treatment options;
    • Atrial fibrillation with slow ventricular response requiring long-term ventricular pacing;
    • New-onset persistent complete left bundle branch block after TAVR, or new-onset advanced AV block after hypertrophic cardiomyopathy ablation;
    • Neuromuscular disease, infiltrative cardiomyopathy, or adult congenital heart disease with progressive AV/branch conduction abnormalities and bradycardia-related symptoms;
    • High infection risk populations (e.g., recurrent pacing system infection, diabetes mellitus, long-term corticosteroid use, end-stage renal disease on dialysis) or patients with abnormal conventional pacing access or at extremely high risk of conventional pacing lead complications.
  3. Anatomical feasibility and vascular access assessment:

    • Preoperative imaging confirms suitable right internal jugular vein access to accommodate the delivery sheath, without thrombosis, severe stenosis, or anatomical malformations;
    • Right ventricular anatomy is suitable with adequate trabeculation to support active fixation of the leadless pacemaker, without severe structural abnormalities;
    • Priority for enrollment: patients with limited femoral or inferior vena cava access (e.g., iliac/inferior vena cava stenosis, thrombosis, prior venous surgery, obesity precluding femoral access).
  4. New York Heart Association (NYHA) functional class ≤ III, and expected survival > 1 year.
  5. Able to cooperate with preoperative evaluation, intraoperative procedure, and 3-month follow-up.
  6. Voluntarily signs written informed consent and agrees to complete all scheduled observations per the study protocol.

Exclusion Criteria:

  1. Anatomical malformations, severe stenosis, occlusion, or thrombosis of the internal jugular vein or superior vena cava that preclude transjugular access for the procedure.
  2. Abnormal right ventricular anatomy, including but not limited to right ventricular hypoplasia, severe right ventricular dilation, or severe right ventricular myocardial fibrosis, preventing safe implantation of an active-fixation leadless ventricular pacemaker.
  3. Severe tricuspid regurgitation, or status post-mechanical tricuspid valve replacement, significantly affecting pacemaker implantation, device fixation, or function.
  4. NYHA functional class IV, or refractory heart failure, cardiogenic shock, rendering the patient unable to tolerate the procedure and perioperative management.
  5. Severe hepatic or renal impairment (eGFR < 30 mL/min/1.73m², severe liver dysfunction), coagulopathy, or active bleeding disorders constituting clear surgical contraindications.
  6. Confirmed allergy or severe intolerance to leadless pacemaker materials, intraoperative contrast media, or anesthetic agents.
  7. Prior implantation of other cardiovascular implantable electronic devices (e.g., pacemaker, ICD, CRT) or retained intracardiac leads/devices that would interfere with the current implantation or device function.
  8. Advanced malignancy, severe active infection, active autoimmune disease, or other serious systemic conditions with an expected survival < 12 months, precluding completion of the 3-month follow-up.
  9. Pregnant or lactating women, or women planning pregnancy during the follow-up period.
  10. Psychiatric disorders, cognitive impairment, or inability to cooperate with preoperative evaluation, intraoperative procedure, or regular postoperative follow-up due to personal or geographic reasons.
  11. Concurrent participation in another cardiovascular device clinical trial that may interfere with the outcome assessment of this study.
  12. Any other condition deemed by the investigator to make the participant unsuitable for enrollment.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: N / D
  • Modelo Intervencional: Atribuição de grupo único
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Experimental: Aveir VR Leadless Pacemaker
Participants will undergo transjugular implantation of the Aveir VR active-fixation leadless ventricular pacemaker. This experimental arm evaluates the procedure and device performance for ventricular pacing indications.
The Aveir VR leadless pacemaker is implanted via a transjugular (jugular vein) approach. This active-fixation device is placed in the right ventricle for ventricular pacing indications.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Rate of Participants with Sustained Successful Aveir VR Lead Implantation (evaluated by fluoroscopy and clinical-electrophysiological follow-up)
Prazo: Through 3 months post-procedure
The percentage of participants with sustained successful Aveir VR lead implantation via trans-jugular venous access at 3-month follow-up. Sustained implantation success is defined as intact lead position, stable pacing parameters, and absence of lead-related complications at the end of 3-month follow-up.
Through 3 months post-procedure
Acute adverse event rate
Prazo: Periprocedural and up to 48 hours
Incidence of adverse events within 48 hours post-procedure, measured as a percentage
Periprocedural and up to 48 hours

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Pacing Threshold (measured in volts)
Prazo: Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Pacing threshold of the Aveir VR lead, measured in volts, to evaluate threshold stability across follow-up time points.
Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
R-wave amplitude
Prazo: Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
R-wave amplitude measured in millivolts.
Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Lead impedance
Prazo: Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Lead impedance measured in ohms.
Baseline, Post-procedure Day 1-3, 1 month, and 3 months post-procedure
Technical success rate
Prazo: Periprocedural
Rate of technical success measured as a percentage.
Periprocedural
Duration of the Implantation Procedure (measured in minutes)
Prazo: Periprocedural
Total time duration of the leadless pacemaker implantation procedure, measured in minutes.
Periprocedural
Fluoroscopy time
Prazo: Periprocedural
Duration of fluoroscopy measured in minutes.
Periprocedural
Number of puncture attempts
Prazo: Periprocedural
Count of puncture attempts measured in number of times.
Periprocedural
Number of lead fixation attempts
Prazo: Periprocedural
Count of fixation attempts measured in number of times.
Periprocedural
Implantation site
Prazo: Periprocedural
Anatomical location of implantation recorded as a categorical variable.
Periprocedural
Correlation between site and parameters
Prazo: Up to 3 months
Pacing parameters by site
Up to 3 months
Adverse event incidence
Prazo: Through 3 months post-procedure
Overall incidence of adverse events measured as a percentage.
Through 3 months post-procedure
Serious adverse event incidence
Prazo: Through 3 months post-procedure
Incidence of serious adverse events measured as a percentage.
Through 3 months post-procedure
Device-related complication rate
Prazo: Through 3 months post-procedure
Rate of device-related complications measured as a percentage.
Through 3 months post-procedure

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: Min Shen, MD, PhD, Department of Cardiovascular Medicine, First Affiliated Hospital of Air Force Medical University

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

10 de setembro de 2026

Conclusão Primária (Estimado)

30 de setembro de 2027

Conclusão do estudo (Estimado)

31 de dezembro de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

21 de agosto de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

30 de agosto de 2026

Primeira postagem (Real)

3 de setembro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

3 de setembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

30 de agosto de 2026

Última verificação

1 de agosto de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Descrição do plano IPD

his is a single-center feasibility study with a small sample size (n=15). Data sharing is not planned due to the limited statistical power and the difficulty in de-identifying such specific clinical data without undue risk.

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

produto fabricado e exportado dos EUA

Sim

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever