The AIM Study: Assessing the Impact of Margin Reduction (AIM)
27. April 2012 aktualisiert von: Varian, a Siemens Healthineers Company
This study will observe patients who receive external beam radiation for prostate cancer.
These patients will be localized and tracked (targeted) with the Calypso 4D Localization System.
These patients will have a uniform treatment plan with reduced PTVs (prostate treatment volume) and will be assessed at multiple time points for quality of life and side effects related to radiation therapy.
Studienübersicht
Detaillierte Beschreibung
EPIC surveys and adverse events recorded and categorized using the CTCAE v3.0 will be collected and summary statistics performed.
The patient's individual tracking graphs will be evaluated for motion type and frequency.
Studientyp
Beobachtungs
Einschreibung (Tatsächlich)
82
Kontakte und Standorte
Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.
Studienorte
-
-
Arizona
-
Scottsdale, Arizona, Vereinigte Staaten, 85251
- 21st Century Oncology - Scottsdale
-
-
California
-
Santa Monica, California, Vereinigte Staaten, 90404
- 21st Century Oncology - Santa Monica
-
-
Florida
-
Cape Coral, Florida, Vereinigte Staaten, 33990
- 21st Century Oncology
-
Plantation, Florida, Vereinigte Staaten, 33324
- 21st Century Oncology - Plantation
-
-
Teilnahmekriterien
Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.
Zulassungskriterien
Studienberechtigtes Alter
18 Jahre und älter (Erwachsene, Älterer Erwachsener)
Akzeptiert gesunde Freiwillige
Nein
Studienberechtigte Geschlechter
Männlich
Probenahmeverfahren
Nicht-Wahrscheinlichkeitsprobe
Studienpopulation
Males diagnosed with prostate cancer
Beschreibung
Inclusion Criteria:
- Patients who are planning to receive external beam radiation of prostate
- Patients who are to be implanted with Beacon Transponders in the prostate
- 18 years of age or older.
- Histologically confirmed diagnosis of prostate cancer.
- Ability to comply with study visit schedule.
- Signed informed consent form.
Exclusion Criteria:
- Any patients who have received other investigational therapy within the last 60 days are excluded.
- Individuals that have previously been implanted with permanent Beacon transponders are excluded.
- Patients that have any prosthetic implants in the pelvic region that contain metal or conductive materials (e.g., an artificial hip).
- Any other medical or other condition that would, at the discretion of the investigator, preclude the individual from participation in a clinical study.
Studienplan
Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.
Wie ist die Studie aufgebaut?
Designdetails
Kohorten und Interventionen
Gruppe / Kohorte |
Intervention / Behandlung |
|---|---|
|
Cohort 1
All patients in study
|
AE monitoring and EPIC QOL survey
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Evaluate patient quality of life using Expanded Prostate Cancer Index Composite (EPIC) for evaluation of the QOL
Zeitfenster: 2 year follow-up
|
2 year follow-up
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Collection of patient tracking data from the Calypso 4D Localization System
Zeitfenster: 9 weeks
|
9 weeks
|
|
Record the number of interventions patients receive during radiation delivery to maintain the target within the treatment plan
Zeitfenster: 9 weeks
|
9 weeks
|
|
Evaluate the user satisfaction with the Calypso 4D Localization System
Zeitfenster: At time of use
|
At time of use
|
|
Evaluate acute and chronic (up to 2 years) toxicities of external beam prostate radiation using Common Terminology Criteria for Adverse Events for standardization of acute and chronic toxicities from the subject
Zeitfenster: 2 year follow-up
|
2 year follow-up
|
Mitarbeiter und Ermittler
Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.
Ermittler
- Hauptermittler: Constantine Mantz, MD, GenesisCare USA
Publikationen und hilfreiche Links
Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.
Allgemeine Veröffentlichungen
- Michalski JM, Purdy JA, Winter K, Roach M 3rd, Vijayakumar S, Sandler HM, Markoe AM, Ritter MA, Russell KJ, Sailer S, Harms WB, Perez CA, Wilder RB, Hanks GE, Cox JD. Preliminary report of toxicity following 3D radiation therapy for prostate cancer on 3DOG/RTOG 9406. Int J Radiat Oncol Biol Phys. 2000 Jan 15;46(2):391-402. doi: 10.1016/s0360-3016(99)00443-5.
- Zietman AL, DeSilvio ML, Slater JD, Rossi CJ Jr, Miller DW, Adams JA, Shipley WU. Comparison of conventional-dose vs high-dose conformal radiation therapy in clinically localized adenocarcinoma of the prostate: a randomized controlled trial. JAMA. 2005 Sep 14;294(10):1233-9. doi: 10.1001/jama.294.10.1233. Erratum In: JAMA. 2008 Feb 27;299(8):899-900.
- Wei JT, Dunn RL, Litwin MS, Sandler HM, Sanda MG. Development and validation of the expanded prostate cancer index composite (EPIC) for comprehensive assessment of health-related quality of life in men with prostate cancer. Urology. 2000 Dec 20;56(6):899-905. doi: 10.1016/s0090-4295(00)00858-x.
- Balter JM, Wright JN, Newell LJ, Friemel B, Dimmer S, Cheng Y, Wong J, Vertatschitsch E, Mate TP. Accuracy of a wireless localization system for radiotherapy. Int J Radiat Oncol Biol Phys. 2005 Mar 1;61(3):933-7. doi: 10.1016/j.ijrobp.2004.11.009.
- Litzenberg DW, Willoughby TR, Balter JM, Sandler HM, Wei J, Kupelian PA, Cunningham AA, Bock A, Aubin M, Roach M 3rd, Shinohara K, Pouliot J. Positional stability of electromagnetic transponders used for prostate localization and continuous, real-time tracking. Int J Radiat Oncol Biol Phys. 2007 Jul 15;68(4):1199-206. doi: 10.1016/j.ijrobp.2007.03.030. Epub 2007 May 21.
- Sanda MG, Dunn RL, Michalski J, Sandler HM, Northouse L, Hembroff L, Lin X, Greenfield TK, Litwin MS, Saigal CS, Mahadevan A, Klein E, Kibel A, Pisters LL, Kuban D, Kaplan I, Wood D, Ciezki J, Shah N, Wei JT. Quality of life and satisfaction with outcome among prostate-cancer survivors. N Engl J Med. 2008 Mar 20;358(12):1250-61. doi: 10.1056/NEJMoa074311.
- Litzenberg DW, Balter JM, Hadley SW, Sandler HM, Willoughby TR, Kupelian PA, Levine L. Influence of intrafraction motion on margins for prostate radiotherapy. Int J Radiat Oncol Biol Phys. 2006 Jun 1;65(2):548-53. doi: 10.1016/j.ijrobp.2005.12.033. Epub 2006 Mar 20.
- Trotti A, Colevas AD, Setser A, Rusch V, Jaques D, Budach V, Langer C, Murphy B, Cumberlin R, Coleman CN, Rubin P. CTCAE v3.0: development of a comprehensive grading system for the adverse effects of cancer treatment. Semin Radiat Oncol. 2003 Jul;13(3):176-81. doi: 10.1016/S1053-4296(03)00031-6.
- Zelefsky MJ, Fuks Z, Hunt M, Yamada Y, Marion C, Ling CC, Amols H, Venkatraman ES, Leibel SA. High-dose intensity modulated radiation therapy for prostate cancer: early toxicity and biochemical outcome in 772 patients. Int J Radiat Oncol Biol Phys. 2002 Aug 1;53(5):1111-6. doi: 10.1016/s0360-3016(02)02857-2.
- Pollack A. "The Prostate" in Radiation Oncology: Rationale, Techniques and Results edited by Cox and Ang. Mosby 2003 p 630.
- Hanks GE, Leibel SA, Krall JM, Kramer S. Patterns of care studies: dose-response observations for local control of adenocarcinoma of the prostate. Int J Radiat Oncol Biol Phys. 1985 Jan;11(1):153-7. doi: 10.1016/0360-3016(85)90374-8.
- Chandra A, Dong L, Huang E, Kuban DA, O'Neill L, Rosen I, Pollack A. Experience of ultrasound-based daily prostate localization. Int J Radiat Oncol Biol Phys. 2003 Jun 1;56(2):436-47. doi: 10.1016/s0360-3016(02)04612-6.
- Rudat V, Schraube P, Oetzel D, Zierhut D, Flentje M, Wannenmacher M. Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer. Int J Radiat Oncol Biol Phys. 1996 Jul 15;35(5):1027-34. doi: 10.1016/0360-3016(96)00204-0.
- Antolak JA, Rosen II, Childress CH, Zagars GK, Pollack A. Prostate target volume variations during a course of radiotherapy. Int J Radiat Oncol Biol Phys. 1998 Oct 1;42(3):661-72. doi: 10.1016/s0360-3016(98)00248-x.
- Little DJ, Dong L, Levy LB, Chandra A, Kuban DA. Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: implications for treatment margins. Int J Radiat Oncol Biol Phys. 2003 Aug 1;56(5):1218-24. doi: 10.1016/s0360-3016(03)00290-6.
- Smitsmans MH, de Bois J, Sonke JJ, Betgen A, Zijp LJ, Jaffray DA, Lebesque JV, van Herk M. Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy. Int J Radiat Oncol Biol Phys. 2005 Nov 15;63(4):975-84. doi: 10.1016/j.ijrobp.2005.07.973.
Studienaufzeichnungsdaten
Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.
Haupttermine studieren
Studienbeginn
1. Juli 2008
Studienabschluss (Tatsächlich)
1. September 2009
Studienanmeldedaten
Zuerst eingereicht
15. September 2008
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
15. September 2008
Zuerst gepostet (Schätzen)
17. September 2008
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
30. April 2012
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
27. April 2012
Zuletzt verifiziert
1. April 2012
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- CMT-03-08
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .