Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Effect of Light Emitting Diode Therapy on Muscle Fatigue (LED)

21. November 2020 aktualisiert von: HAhmed, Cairo University

Effect of Different Pre Application Time Intervals of Light Emitting Diode Therapy on Muscle

The purpose of this study is to determine the optimal time interval between light emitting diode application and exercise to improve fatigue resistance.The results of this study could be useful in planning a rehabilitation program in musculature disorders and also in athletic training.

Studienübersicht

Status

Unbekannt

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

  1. To determine the effect of light emitting diode applied 5 minutes before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
  2. To determine the effect of light emitting diode applied 1 hour before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
  3. To determine the effect of light emitting diode applied 5 hours before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
  4. To determine the difference between light emitting diode applied 5 minutes,1 hour or 5 hours before exercise on pain, rate of perceived exertion and maximum voluntary contraction.

Studientyp

Interventionell

Einschreibung (Voraussichtlich)

30

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Cairo, Ägypten
        • Faculty of Physical Therapy

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

20 Jahre bis 40 Jahre (Erwachsene)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Healthy non athletics subjects.
  • Age ranges from 20-40 years.
  • Body mass index is less than 25 kg/m 2

Exclusion Criteria:

  • Neurological deficit and recent injury to either upper extremity
  • non diagnosed pain .
  • Contraindications to LED irradiation (such as light hypersensitivity, fluctuating blood pressure, insufficient blood circulation, fever and inflammation of the skin)
  • Conditions in which physical exertion is contraindicated (such as cardiovascular deficits, hypertension and respiratory problems)
  • Restriction in shoulder or elbow range of motion;
  • Neoplasm,
  • Rheumatoid,
  • Strength training in the past 6 months;
  • Previous surgery in the spine or upper extremity;
  • Complaints of pain in the shoulder, elbow,wrist, and trunk musculature system;
  • Use of dietary supplements; and not in any other exercise program for at least the past 3 months.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Verhütung
  • Zuteilung: Zufällig
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Single

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: 5 minutes before 1
Light emitting diode applied 5 minutes before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Placebo-Komparator: 5 minutes before 2
Light emitting diode applied 5 minutes before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Experimental: 1 hour before 1
Light emitting diode applied 1 hour before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Placebo-Komparator: 1 hour before 2
Light emitting diode applied 1 hour before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Experimental: 5 hours before 1
Light emitting diode applied 5 hours before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Placebo-Komparator: 5 hours before 2
Light emitting diode applied 5 hours before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Isometric peak torque of elbow flexors
Zeitfenster: change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
metric unit is Newton
change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
Isometric peak torque of elbow flexors
Zeitfenster: change from before light emitting diode application at1 minute
metric unit is Newton
change from before light emitting diode application at1 minute
Isokinetic peak torque of elbow flexors
Zeitfenster: change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
Metric unit is Newton and at angular velocity 60
change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
Isokinetic peak torque of elbow flexors
Zeitfenster: change from before light emitting diode application at 1 minute after light emitting diode application
Metric unit is Newton and at angular velocity 60
change from before light emitting diode application at 1 minute after light emitting diode application

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

1. November 2020

Primärer Abschluss (Voraussichtlich)

1. Januar 2021

Studienabschluss (Voraussichtlich)

1. Januar 2021

Studienanmeldedaten

Zuerst eingereicht

24. Januar 2020

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

28. April 2020

Zuerst gepostet (Tatsächlich)

29. April 2020

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

25. November 2020

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

21. November 2020

Zuletzt verifiziert

1. November 2020

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Zusätzliche relevante MeSH-Bedingungen

Andere Studien-ID-Nummern

  • P.T.REC/012/002480

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren