Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Effect of Light Emitting Diode Therapy on Muscle Fatigue (LED)

21. november 2020 opdateret af: HAhmed, Cairo University

Effect of Different Pre Application Time Intervals of Light Emitting Diode Therapy on Muscle

The purpose of this study is to determine the optimal time interval between light emitting diode application and exercise to improve fatigue resistance.The results of this study could be useful in planning a rehabilitation program in musculature disorders and also in athletic training.

Studieoversigt

Status

Ukendt

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

  1. To determine the effect of light emitting diode applied 5 minutes before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
  2. To determine the effect of light emitting diode applied 1 hour before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
  3. To determine the effect of light emitting diode applied 5 hours before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
  4. To determine the difference between light emitting diode applied 5 minutes,1 hour or 5 hours before exercise on pain, rate of perceived exertion and maximum voluntary contraction.

Undersøgelsestype

Interventionel

Tilmelding (Forventet)

30

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Cairo, Egypten
        • Faculty of physical therapy

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

20 år til 40 år (Voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Healthy non athletics subjects.
  • Age ranges from 20-40 years.
  • Body mass index is less than 25 kg/m 2

Exclusion Criteria:

  • Neurological deficit and recent injury to either upper extremity
  • non diagnosed pain .
  • Contraindications to LED irradiation (such as light hypersensitivity, fluctuating blood pressure, insufficient blood circulation, fever and inflammation of the skin)
  • Conditions in which physical exertion is contraindicated (such as cardiovascular deficits, hypertension and respiratory problems)
  • Restriction in shoulder or elbow range of motion;
  • Neoplasm,
  • Rheumatoid,
  • Strength training in the past 6 months;
  • Previous surgery in the spine or upper extremity;
  • Complaints of pain in the shoulder, elbow,wrist, and trunk musculature system;
  • Use of dietary supplements; and not in any other exercise program for at least the past 3 months.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Forebyggelse
  • Tildeling: Randomiseret
  • Interventionel model: Crossover opgave
  • Maskning: Enkelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: 5 minutes before 1
Light emitting diode applied 5 minutes before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Placebo komparator: 5 minutes before 2
Light emitting diode applied 5 minutes before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Eksperimentel: 1 hour before 1
Light emitting diode applied 1 hour before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Placebo komparator: 1 hour before 2
Light emitting diode applied 1 hour before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Eksperimentel: 5 hours before 1
Light emitting diode applied 5 hours before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
Placebo komparator: 5 hours before 2
Light emitting diode applied 5 hours before fatiguing task
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Isometric peak torque of elbow flexors
Tidsramme: change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
metric unit is Newton
change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
Isometric peak torque of elbow flexors
Tidsramme: change from before light emitting diode application at1 minute
metric unit is Newton
change from before light emitting diode application at1 minute
Isokinetic peak torque of elbow flexors
Tidsramme: change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
Metric unit is Newton and at angular velocity 60
change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
Isokinetic peak torque of elbow flexors
Tidsramme: change from before light emitting diode application at 1 minute after light emitting diode application
Metric unit is Newton and at angular velocity 60
change from before light emitting diode application at 1 minute after light emitting diode application

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. november 2020

Primær færdiggørelse (Forventet)

1. januar 2021

Studieafslutning (Forventet)

1. januar 2021

Datoer for studieregistrering

Først indsendt

24. januar 2020

Først indsendt, der opfyldte QC-kriterier

28. april 2020

Først opslået (Faktiske)

29. april 2020

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

25. november 2020

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

21. november 2020

Sidst verificeret

1. november 2020

Mere information

Begreber relateret til denne undersøgelse

Yderligere relevante MeSH-vilkår

Andre undersøgelses-id-numre

  • P.T.REC/012/002480

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Light emitting diode

3
Abonner