Use of a Compliant Balloon for Large Bore Catheter Navigation in Mechanical Thrombectomy for Stroke: a Retrospective Study
se of ADAPT Assisted by a Compliant Balloon (ADAPT-AB) When ADAPT Fails for Acute Stroke Thrombectomy
The superiority of mechanical thrombectomy (MT) in patients with acute ischemic stroke from large vessel occlusion compared to standard medical therapy alone has been demonstrated by several randomized clinical trials and become the standard of care for these patients. A direct aspiration first pass technique (ADAPT) for the endovascular treatment of stroke using a large-bore catheter has been reported to be an effective method of achieving MT. Recent studies reported that ADAPT is as efficient and safe as stent retrievers, with a similar successful recanalization rate, but may have better functional outcomes, fewer procedure related-adverse events, and a tendency for faster revascularization compared to the stent-retriever thrombectomy.
However, navigation of a large-bore aspiration catheter is not always possible due to unsuccessful passage of the ophthalmic artery origin ("ledge effect") or tortuous vascular anatomy. The coaxial technique comprises guiding the large-bore catheter with a smaller inner catheter and can facilitate distal access. However, there is a gap between the inner catheter and the distal tip of the large-bore outer catheter that creates a risk of damaging the vessel wall and causing dissection or subarachnoid hemorrhage. Even with this coaxial technique, it is not always possible to reach the clot site with the large-bore catheter. To decrease the gap between the two catheters, several authors have used, in place of the inner microcatheter, a compliant balloon catheter positioned and inflated at the distal tip of the large-bore catheter. The aim of the present study was to evaluate the safety and efficacy of ADAPT assisted by a compliant balloon (ADAPT-AB) when ADAPT using the coaxial technique fails to reach the clot site.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Studientyp
Einschreibung (Tatsächlich)
Kontakte und Standorte
Studienorte
-
-
-
Nice, Frankreich, 06000
- CHU de Nice
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- Endovascular therapy were large arterial occlusions proven by MR angiography,
- Alberta Stroke Program Early CT Score (ASPECTS) >5 on MRI,
- Baseline National Institutes of Health Stroke Scale (NIHSS) score >5.
If eligible, patients received intravenous thrombolysis (IVT).
Exclusion criteria:
- Vertebro-basilar occlusion
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Kohorten und Interventionen
Gruppe / Kohorte |
Intervention / Behandlung |
---|---|
Mechanical thrombectomy
Patients who underwent mechanical thrombectomy for large vessel occlusion of the anterior circulation
|
Use of a compliant balloon when ADAPT fails to reach the clot site
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
---|---|---|
Efficacity to reach the clot site when using an inner balloon
Zeitfenster: Day 0
|
Number of patients for whom the balloon made it possible to reach the clot
|
Day 0
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
---|---|---|
Clinical status at 3 month
Zeitfenster: Month 3
|
Modified Rankin Score
|
Month 3
|
Endovascular Complication
Zeitfenster: Day 0
|
Number of dissection or vasospasm when using the balloon
|
Day 0
|
Mitarbeiter und Ermittler
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 21Imagerie01
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Compliant balloon
-
University Hospital MuensterAbgeschlossenMagen-Darm-ErkrankungenDeutschland, Niederlande, Norwegen
-
Fundación EPICAbgeschlossenHerz-Kreislauf-Erkrankungen | Arterielle ErkrankungSpanien
-
Urotronic Inc.Abgeschlossen
-
Guangdong Provincial People's HospitalShenzhen People's Hospital; Kashgar 1st People's HospitalUnbekannt
-
University Hospital MuensterAzienda Ospedaliera San Giovanni Battista; Albert Schweitzer Hospital; Nuovo Ospedale...Abgeschlossen
-
AcclarentAbgeschlossenChronische SinusitisVereinigte Staaten
-
Johnson & Johnson Medical CompaniesAcclarentBeendet
-
Caritasklinik St. TheresiaUnbekanntPeriphere arterielle Verschlusskrankheit | Femoropoliteale Stenose/Okklusion | Schneidballon | Mit Medikamenten beschichteter BallonDeutschland
-
Chinese PLA General HospitalUnbekannt
-
Airiver Medical, Inc.RekrutierungChronische RhinosinusitisParaguay